Glass-composite prototyping for flow PCR with in situ DNA analysis

In this article, low cost microfluidic devices have been used for simultaneous amplification and analysis of DNA. Temperature gradient flow PCR was performed, during which the unique fluorescence signature of the amplifying product was determined. The devices were fabricated using xurography, a fast and highly flexible prototype manufacturing method. Each complete iterative design cycle, from concept to prototype, was completed in less than 1 h. The resulting devices were of a 96% glass composition, thereby possessing a high thermal stability during continuous-flow PCR. Volumetric flow rates up to 4 µl/min induced no measurable change in the temperature distribution within the microchannel. By incorporating a preliminary channel passivation protocol, even the first microliters through the system exhibited a high amplification efficiency, thereby demonstrating the biocompatibility of this fabrication technique for DNA amplification microfluidics. The serpentine microchannel induced 23 temperature gradient cycles in 15 min at a 2 µl/min flow rate. Fluorescent images of the device were acquired while and/or after the PCR mixture filled the microchannel. Because of the relatively high initial concentration of the phage DNA template (ΦX174), images taken after 10 min (less than 15 PCR cycles) could be used to positively identify the PCR product. A single fluorescent image of a full device provided the amplification curve for the entire reaction as well as multiple high resolution melting curves of the amplifying sample. In addition, the signal-to-noise ratio associated with the spatial fluorescence was characterized as a function of spatial redundancy and acquisition time.

[1]  H. John Crabtree,et al.  Microfabricated device for DNA and RNA amplification by continuous-flow polymerase chain reaction and reverse transcription-polymerase chain reaction with cycle number selection. , 2003, Analytical chemistry.

[2]  Pin-Chuan Chen,et al.  Rapid PCR in a continuous flow device. , 2004, Lab on a chip.

[3]  C. Wittwer,et al.  Spatial DNA melting analysis for genotyping and variant scanning. , 2009, Analytical chemistry.

[4]  Yuzuru Takamura,et al.  Circumventing air bubbles in microfluidic systems and quantitative continuous-flow PCR applications , 2006, Analytical and bioanalytical chemistry.

[5]  D. Bartholomeusz,et al.  Xurography: rapid prototyping of microstructures using a cutting plotter , 2005, Journal of Microelectromechanical Systems.

[6]  A Manz,et al.  Chemical amplification: continuous-flow PCR on a chip. , 1998, Science.

[7]  Bruce Gale,et al.  Continuous-flow thermal gradient PCR , 2008, Biomedical microdevices.

[8]  J. Köhler,et al.  Miniaturized flow-through PCR with different template types in a silicon chip thermocycler. , 2001, Lab on a chip.

[9]  Holger Becker,et al.  Polymer microfabrication technologies for microfluidic systems , 2008, Analytical and bioanalytical chemistry.

[10]  C. Wittwer,et al.  Flow-induced thermal effects on spatial DNA melting. , 2008, Lab on a chip.

[11]  Carl T. Wittwer,et al.  Comparison of glass etching to xurography prototyping of microfluidic channels for DNA melting analysis , 2007 .

[12]  Robert Palais,et al.  Product differentiation during continuous-flow thermal gradient PCR. , 2008, Lab on a chip.

[13]  J. Sninsky,et al.  PCR Applications: Protocols for Functional Genomics , 1999 .

[14]  C. Wittwer,et al.  Closed-tube genotyping with unlabeled oligonucleotide probes and a saturating DNA dye. , 2004, Clinical chemistry.

[15]  C. Wittwer,et al.  14 – Rapid thermal cycling and PCR kinetics , 1999 .

[16]  K. Voelkerding,et al.  Amplicon DNA melting analysis for mutation scanning and genotyping: cross-platform comparison of instruments and dyes. , 2006, Clinical chemistry.

[17]  Viktor Stein,et al.  Continuous-flow polymerase chain reaction of single-copy DNA in microfluidic microdroplets. , 2009, Analytical chemistry.

[18]  Ivan Erill,et al.  Biochemical analysis and optimization of inhibition and adsorption phenomena in glass–silicon PCR-chips , 2003 .

[19]  C. Wittwer,et al.  Solution-phase DNA mutation scanning and SNP genotyping by nanoliter melting analysis , 2007, Biomedical microdevices.