Optode positional calibration in diffuse optical tomography.

Although diffuse optical tomography is a highly promising technique used to noninvasively image blood volume and oxygenation, the reconstructed data are sensitive to systemic difference between the forward model and the actual experimental conditions. In particular, small changes in optode location or in the optode-tissue coupling coefficient significantly degrade the quality of the reconstruction images. Accurate system calibration therefore is an essential part of any experimental protocol. We present a technique for simultaneously calibrating optode positions and reconstructing images that significantly improves image quality, as we demonstrate with simulations and phantom experiments.

[1]  R. Cubeddu,et al.  Optical Tomography , 1998, Technical Digest. 1998 EQEC. European Quantum Electronics Conference (Cat. No.98TH8326).

[2]  M. Schweiger,et al.  A finite element approach for modeling photon transport in tissue. , 1993, Medical physics.

[3]  B. Chance Near-infrared (NIR) optical spectroscopy characterizes breast tissue hormonal and age status. , 2001, Academic radiology.

[4]  Eric L. Miller,et al.  Comparison of linear reconstruction techniques for 3D DPDW imaging of absorption coefficient , 1999, Photonics West - Biomedical Optics.

[5]  A. Hielscher,et al.  Volumetric imaging of hemodynamic effects in the human brain by three-dimensional diffuse optical tomography , 2002 .

[6]  K D Paulsen,et al.  Spectroscopic diffuse optical tomography for the quantitative assessment of hemoglobin concentration and oxygen saturation in breast tissue. , 1999, Applied optics.

[7]  E. Gratton,et al.  Non-invasive optical mapping of the piglet brain in real time. , 1999, Optics express.

[8]  G. Golub,et al.  Scientific Computing and Differential Equations: An Introduction to Numerical Methods , 1991 .

[9]  B. Tromberg,et al.  Sources of absorption and scattering contrast for near-infrared optical mammography. , 2001, Academic radiology.

[10]  S. Arridge Optical tomography in medical imaging , 1999 .

[11]  C H Schmitz,et al.  Optical tomographic imaging of dynamic features of dense-scattering media. , 2001, Journal of the Optical Society of America. A, Optics, image science, and vision.

[12]  B. Pogue,et al.  Frequency-domain optical absorption spectroscopy of finite tissue volumes using diffusion theory. , 1994, Physics in medicine and biology.

[13]  E. Wolf,et al.  Principles of Optics (7th Ed) , 1999 .

[14]  Chance,et al.  Refraction of diffuse photon density waves. , 1992, Physical review letters.

[15]  D Boas,et al.  Simultaneous imaging and optode calibration with diffuse optical tomography. , 2001, Optics express.

[16]  Turgut Durduran,et al.  Diffuse optical measurement of hemoglobin and cerebral blood flow in rat brain during hypercapnia, hypoxia and cardiac arrest. , 2003, Advances in experimental medicine and biology.

[17]  B. Chance,et al.  Spectroscopy and Imaging with Diffusing Light , 1995 .

[18]  E. Gratton,et al.  On-line optical imaging of the human brain with 160-ms temporal resolution. , 2000, Optics express.

[19]  L. O. Svaasand,et al.  Properties of photon density waves in multiple-scattering media. , 1993, Applied optics.

[20]  P M Schlag,et al.  Development of a time-domain optical mammograph and first in vivo applications. , 1999, Applied optics.

[21]  B. Wilson,et al.  Time resolved reflectance and transmittance for the non-invasive measurement of tissue optical properties. , 1989, Applied optics.