Air-Gap Power-Based Sensorless Control in a DFIG Connected to a DC Link

This paper deals with the sensorless vector control of a doubly fed induction generator (DFIG) whose stator is connected by a rectifier to a dc link, which also feeds the rotor-side inverter. A noticeable reduction of the costs can be achieved by this topology, because only a single inverter and a diode rectifier are needed instead of the traditional back-to-back converter. A sensorless stator-flux-oriented control is implemented by using an observer, which directly computes the necessary slip angle based on of the air-gap power and without the need of the stator flux estimation. The direct-axis component of the rotor current is adjusted to regulate the stator frequency near the rated value. In order to track the actual stator frequency, the phase-locked-loop approach is used. The control method is validated by simulations and experimental results obtained using a small-rating laboratory setup.

[1]  G. D. Marques,et al.  Stator Frequency Regulation in a Field-Oriented Controlled DFIG Connected to a DC Link , 2014, IEEE Transactions on Industrial Electronics.

[2]  Stefan Lundberg Wind Farm Configuration and Energy Efficiency Studies - Series DC versus AC Layouts , 2006 .

[3]  Heng Nian,et al.  Dynamic Modeling and Improved Control of DFIG Under Distorted Grid Voltage Conditions , 2011, IEEE Transactions on Energy Conversion.

[4]  Matteo F. Iacchetti,et al.  Inner Control Method and Frequency Regulation of a DFIG Connected to a DC Link , 2014, IEEE Transactions on Energy Conversion.

[5]  Tomonobu Senjyu,et al.  A distributed DC power system in an isolated island , 2009, 2009 IEEE International Symposium on Industrial Electronics.

[6]  Amit K. Jain,et al.  Wound Rotor Induction Generator With Sensorless Control and Integrated Active Filter for Feeding Nonlinear Loads in a Stand-Alone Grid , 2008, IEEE Transactions on Industrial Electronics.

[7]  Hiroaki Kakigano,et al.  DC Micro-grid for Super High Quality Distribution — System Configuration and Control of Distributed Generations and Energy Storage Devices — , 2006 .

[8]  Longya Xu,et al.  A New High-Frequency Injection Method for Sensorless Control of Doubly Fed Induction Machines , 2012 .

[9]  Yongzheng Zhang,et al.  Sensorless Maximum Power Point Tracking of Wind by DFIG Using Rotor Position Phase Lock Loop (PLL) , 2009, IEEE Transactions on Power Electronics.

[10]  J.A.P. Lopes,et al.  Defining control strategies for MicroGrids islanded operation , 2006, IEEE Transactions on Power Systems.

[11]  Matteo F. Iacchetti,et al.  Sensorless torque control of a DFIG connected to a DC link , 2013, 2013 IEEE International Symposium on Sensorless Control for Electrical Drives and Predictive Control of Electrical Drives and Power Electronics (SLED/PRECEDE).

[12]  M. Monfared,et al.  Design-Oriented Study of Advanced Synchronous Reference Frame Phase-Locked Loops , 2013, IEEE Transactions on Power Electronics.

[13]  Roberto Cárdenas,et al.  Overview of control systems for the operation of DFIGs in wind energy applications , 2013, IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society.

[14]  F. Blaabjerg,et al.  Power electronics as efficient interface in dispersed power generation systems , 2004, IEEE Transactions on Power Electronics.

[15]  G. D. Marques,et al.  Sensorless Direct Slip Position Estimator of a DFIM Based on the Air Gap $pq$ Vector—Sensitivity Study , 2013, IEEE Transactions on Industrial Electronics.

[16]  Francesco Castelli-Dezza,et al.  An Observer for Sensorless DFIM Drives Based on the Natural Fifth Harmonic of the Line Voltage, Without Stator Current Measurement , 2013, IEEE Transactions on Industrial Electronics.

[17]  Marta Molinas,et al.  A Study of Efficiency in a Reduced Matrix Converter for Offshore Wind Farms , 2012, IEEE Transactions on Industrial Electronics.

[18]  Guillermo O. García,et al.  Adaptive Observer for Sensorless Control of Stand-Alone Doubly Fed Induction Generator , 2009, IEEE Transactions on Industrial Electronics.

[19]  Greg Asher,et al.  MRAS Observers for Sensorless Control of Doubly-Fed Induction Generators , 2008 .

[20]  G. D. Marques,et al.  Understanding the Doubly Fed Induction Generator During Voltage Dips , 2012, IEEE Transactions on Energy Conversion.

[21]  S. Chowdhury,et al.  Microgrids and Active Distribution Networks , 2009 .

[22]  Lingling Fan,et al.  Harmonic Analysis of a DFIG for a Wind Energy Conversion System , 2010, IEEE Transactions on Energy Conversion.

[23]  Gil D. Marques,et al.  An Open-Loop Sensorless Slip Position Estimator of a DFIM Based on Air-gap Active Power Calculations—Sensitivity Study , 2013, IEEE Transactions on Energy Conversion.

[24]  R. Perini,et al.  An MRAS Observer for Sensorless DFIM Drives With Direct Estimation of the Torque and Flux Rotor Current Components , 2012, IEEE Transactions on Power Electronics.

[25]  F. Liu,et al.  DC Bus Voltage Control for a Distributed Power System , 2003 .

[26]  David J. Perreault,et al.  Performance improvement of alternators with switched-mode rectifiers , 2003, IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03..

[27]  Hong-Hee Lee,et al.  Control Strategy for Harmonic Elimination in Stand-Alone DFIG Applications With Nonlinear Loads , 2011, IEEE Transactions on Power Electronics.

[28]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[29]  J.A.M. Bleijs Continuous Conduction Mode Operation of Three-Phase Diode Bridge Rectifier with Constant Load Voltage , 2005 .

[30]  G. D. Marques,et al.  Stator Inductance Self-Tuning in an Air-Gap-Power-Vector-Based Observer for the Sensorless Control of Doubly Fed Induction Machines , 2014, IEEE Transactions on Industrial Electronics.

[31]  C. Nagamani,et al.  A Versatile Rotor Position Computation Algorithm for the Power Control of a Grid-Connected Doubly Fed Induction Generator , 2012, IEEE Transactions on Energy Conversion.

[32]  V. T. Ranganathan,et al.  A simple position-sensorless algorithm for rotor-side field-oriented control of wound-rotor induction machine , 2001, IEEE Trans. Ind. Electron..

[33]  Pavol Bauer,et al.  A Novel Distributed Direct-Voltage Control Strategy for Grid Integration of Offshore Wind Energy Systems Through MTDC Network , 2013, IEEE Transactions on Industrial Electronics.

[34]  Roberto Cárdenas,et al.  Sensorless Control of Doubly-Fed Induction Generators Using a Rotor-Current-Based MRAS Observer , 2008, IEEE Transactions on Industrial Electronics.