Selective Wireless Stimulation of Rat Sciatic Nerve*

Chronic stability of functional performance is a significant challenge to the success of implantable devices for neural stimulation and recording. Integrating wireless technology with typical microelectrode array designs is one approach that may reduce instances of mechanical failure and improve the long-term performance of neural devices. We have investigated the long-term stability of Wireless Floating Microelectrode Arrays (WMFAs) implanted in rat sciatic nerve, and their ability to selectively recruit muscles in the hind limb via neural stimulation. Thresholds as low as 4.1 μA were able to generate visible motion of the rear paw. Each implanted device (n=6) was able to selectively recruit plantar flexion and dorsiflexion of the rear paw, and selective stimulation of both movements was achieved throughout the study period. The evoked limb motion was electrode specific and was dependent on location within the fascicular structure of the nerve. Motor thresholds and movement patterns remained stable for more than 8 weeks after device implantation. No major changes in limb function were observed between the implanted and contralateral limb, or between implanted animals and control group animals. The results of this study show that WFMAs with intrafascicular electrodes implanted in a healthy peripheral nerve can provide stable and selective motor recruitment, without altering overall limb function.

[1]  Glenn A. DeMichele,et al.  Inductively-coupled power and data link for neural prostheses using a class-E oscillator and FSK modulation , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).

[2]  Maysam Ghovanloo,et al.  An Implantable Peripheral Nerve Recording and Stimulation System for Experiments on Freely Moving Animal Subjects , 2018, Scientific Reports.

[3]  Benjamin C. Johnson,et al.  StimDust: A mm-scale implantable wireless precision neural stimulator with ultrasonic power and communication , 2018, 1807.07590.

[4]  Edward Keefer,et al.  Fascicle specific targeting for selective peripheral nerve stimulation , 2019, Journal of neural engineering.

[5]  C. Azevedo-Coste,et al.  Comparative analysis of transverse intrafascicular multichannel, longitudinal intrafascicular and multipolar cuff electrodes for the selective stimulation of nerve fascicles , 2011, Journal of neural engineering.

[6]  Alteration of neural geometry for selective nerve stimulation , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[7]  Philip R. Troyk,et al.  Intrinsic activation of iridium electrodes over a wireless link , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[8]  L. Rieth,et al.  Evaluation of the packaging and encapsulation reliability in fully integrated, fully wireless 100 channel Utah Slant Electrode Array (USEA): Implications for long term functionality , 2011, 2011 16th International Solid-State Sensors, Actuators and Microsystems Conference.

[9]  Stuart F. Cogan,et al.  Chronic in-vivo testing of a 16-channel implantable wireless neural stimulator , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[10]  R. Normann,et al.  Assessment of rat sciatic nerve function following acute implantation of high density utah slanted electrode array (25 electrodes/mm2) based on neural recordings and evoked muscle activity , 2014, Muscle & nerve.

[11]  Dustin J. Tyler,et al.  Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in a human amputee , 2013 .

[12]  W. Grill,et al.  Quantification of recruitment properties of multiple contact cuff electrodes. , 1996, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[13]  P.R. Troyk,et al.  A Multifunctional Neural Electrode Stimulation ASIC using NeuroTalkTM Interface , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[14]  Srikanth Vasudevan,et al.  Rodent model for assessing the long term safety and performance of peripheral nerve recording electrodes , 2017, Journal of neural engineering.