Evaluation of a Volumetric Dried Blood Spot Card Using a Gravimetric Method and a Bioanalytical Method with Capillary Blood from 44 Volunteers.

Dried blood spot (DBS) sampling is a promising method for collection of microliter blood samples. However, hematocrit-related bias in combination with subpunch analysis can result in inaccurate quantification of analytes in DBS samples. In this study we use a microfluidic DBS card, designed to automatically collect fixed volume DBS samples irrespective of the blood hematocrit, to measure caffeine concentration in normal finger prick samples obtained from 44 human individuals. Caffeine levels originating from blood drops of unknown volume collected on the volumetric microfluidic DBS card were compared to volume-controlled pipetted DBS samples from the same finger prick. Hematocrit independence and volumetric sampling performances were also verified on caffeine-spiked blood samples in vitro, using both LC-MS/MS and gravimetric methods, on hematocrits from 26 to 62%. The gravimetric measurements show an excellent metering performance of the microfluidic DBS card, with a mean blood sample volume of 14.25 μL ± 3.0% ( n = 51). A measured mean bias below 2.9% compared to normal hematocrit (47%) demonstrates that there is no significant hematocrit-induced bias. LC-MS/MS measurements confirm low CV and hematocrit independence of the sampling system and exhibit no substantial mean bias compared to pipetted DBS. Tests with 44 individuals demonstrated applicability of the microfluidic DBS card for direct finger prick blood sampling, and measured caffeine concentrations show a good agreement with measurements of pipetted DBS. The presented concept demonstrates a good volumetric performance which can help to improve the accuracy of DBS analysis by analyzing a whole spot, equivalent to a defined volume of liquid blood.

[1]  C. Stove,et al.  Evaluation of the Capitainer-B Microfluidic Device as a New Hematocrit-Independent Alternative for Dried Blood Spot Collection. , 2018, Analytical chemistry.

[2]  K. Bateman,et al.  Extractability‐mediated stability bias and hematocrit impact: High extraction recovery is critical to feasibility of volumetric adsorptive microsampling (VAMS) in regulated bioanalysis , 2018, Journal of pharmaceutical and biomedical analysis.

[3]  M. Breadmore,et al.  Precise, accurate and user-independent blood collection system for dried blood spot sample preparation , 2018, Analytical and Bioanalytical Chemistry.

[4]  Ellen K Silbergeld,et al.  State of the Science in Dried Blood Spots. , 2018, Clinical chemistry.

[5]  A. Helander,et al.  Study of measurement of the alcohol biomarker phosphatidylethanol (PEth) in dried blood spot (DBS) samples and application of a volumetric DBS device. , 2018, Clinica chimica acta; international journal of clinical chemistry.

[6]  N. Spooner,et al.  Investigation of the effect of blood hematocrit and lipid content on the blood volume deposited by a disposable dried blood spot collection device , 2018, Journal of pharmaceutical and biomedical analysis.

[7]  C. Stove,et al.  Dried blood spots in therapeutic drug monitoring and toxicology , 2018, Expert opinion on drug metabolism & toxicology.

[8]  D. Eichner,et al.  Mass Spectrometry Method to Measure Membrane Proteins in Dried Blood Spots for the Detection of Blood Doping Practices in Sport. , 2017, Analytical chemistry.

[9]  T. Dervieux,et al.  Capillary blood collected on volumetric absorptive microsampling (VAMS) device for monitoring hydroxychloroquine in rheumatoid arthritis patients , 2017, Journal of pharmaceutical and biomedical analysis.

[10]  Guan-Yuan Chen,et al.  Sensitive screening of abused drugs in dried blood samples using ultra-high-performance liquid chromatography-ion booster-quadrupole time-of-flight mass spectrometry. , 2017, Journal of chromatography. A.

[11]  S. Bakker,et al.  Dried blood spot validation of five immunosuppressants, without hematocrit correction, on two LC-MS/MS systems. , 2017, Bioanalysis.

[12]  M. Barfield,et al.  Ensuring the collection of high-quality dried blood spot samples across multisite clinical studies. , 2017, Bioanalysis.

[13]  C. Masimirembwa,et al.  Might ART Adherence Estimates Be Improved by Combining Biomarker and Self-Report Data? , 2016, PloS one.

[14]  M. Joore,et al.  Cost Evaluation of Dried Blood Spot Home Sampling as Compared to Conventional Sampling for Therapeutic Drug Monitoring in Children , 2016, PloS one.

[15]  K. Bateman,et al.  An Integrated Strategy for Implementation of Dried Blood Spots in Clinical Development Programs , 2016, The AAPS Journal.

[16]  J. Martínez,et al.  Application of dried blood spots to determine vitamin D status in a large nutritional study with unsupervised sampling: the Food4Me project , 2015, British Journal of Nutrition.

[17]  G. Lawson,et al.  Self-sampling and quantitative analysis of DBS: can it shift the balance in over-burdened healthcare systems? , 2015, Bioanalysis.

[18]  Gabriel Lenk,et al.  A disposable sampling device to collect volume-measured DBS directly from a fingerprick onto DBS paper. , 2015, Bioanalysis.

[19]  O. Beck,et al.  A LC-MS/MS method for therapeutic drug monitoring of carbamazepine, lamotrigine and valproic acid in DBS. , 2015, Bioanalysis.

[20]  M. Honing,et al.  A new DBS card with spot sizes independent of the hematocrit value of blood. , 2015, Bioanalysis.

[21]  N. Roxhed,et al.  The effect of drying on the homogeneity of DBS. , 2015, Bioanalysis.

[22]  W. Lambert,et al.  Does volumetric absorptive microsampling eliminate the hematocrit bias for caffeine and paraxanthine in dried blood samples? A comparative study. , 2015, Analytica chimica acta.

[23]  A. Sakhi,et al.  Feasibility of self-sampled dried blood spot and saliva samples sent by mail in a population-based study , 2015, BMC Cancer.

[24]  Aurélien Thomas,et al.  New microfluidic-based sampling procedure for overcoming the hematocrit problem associated with dried blood spot analysis. , 2015, Analytical chemistry.

[25]  W. Lambert,et al.  Spot them in the spot: analysis of abused substances using dried blood spots. , 2014, Bioanalysis.

[26]  N. Spooner,et al.  Volumetric absorptive microsampling: a dried sample collection technique for quantitative bioanalysis. , 2014, Analytical chemistry.

[27]  P. Demirev Dried blood spots: analysis and applications. , 2013, Analytical chemistry.

[28]  N. Spooner,et al.  The effect of hematocrit and punch location on assay bias during quantitative bioanalysis of dried blood spot samples. , 2011, Bioanalysis.

[29]  Josephine Ec Burnett,et al.  Dried blood spot sampling: practical considerations and recommendation for use with preclinical studies. , 2011, Bioanalysis.

[30]  Sharon Williams,et al.  What a drop can do: Dried blood spots as a minimally invasive method for integrating biomarkers into population-based research , 2007, Demography.

[31]  Neil Spooner,et al.  The effect of hematocrit on assay bias when using DBS samples for the quantitative bioanalysis of drugs. , 2010, Bioanalysis.

[32]  P. Hamilton,et al.  CALCULATION OF HEMOGLOBIN FROM BLOOD SPECIFIC GRAVITIES , 1950 .