Gridded Ionization Chambers for Time Resolved X-Ray Absorption Spectroscopy

Common parallel plate ionization chambers are bandwidth limited by the ion drift velocity. Therefore they can severely decrease the effective energy resolution of time resolved EXAFS or XANES spectra. We therefore developed gridded ionization chambers which suppress the ionic component of the ionization current, which results in a substantial improvement of its bandwidth of typically two orders of magnitude. The rise time of these chambers is measured to be less than 5.5 μs. We have investigated the step response of parallel plate and gridded ionization chambers and discuss their influence on QEXAFS spectra.

[1]  R. Frahm,et al.  Quick scanning exafs: First experiments , 1988 .

[2]  D. Lützenkirchen-Hecht,et al.  Piezo-XAFS–time-resolved x-ray absorption spectroscopy , 2002 .

[3]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[4]  G. Knoll Radiation detection and measurement , 1979 .

[5]  S. Belin,et al.  The SAMBA quick-EXAFS monochromator: XAS with edge jumping. , 2012, Journal of synchrotron radiation.

[6]  J. Grunwaldt,et al.  Identification of the active species generated from supported Pd catalysts in Heck reactions: an in situ quick scanning EXAFS investigation. , 2011, Journal of the American Chemical Society.

[7]  J. Grunwaldt,et al.  Structural changes of noble metal catalysts during ignition and extinction of the partial oxidation of methane studied by advanced QEXAFS techniques. , 2009, Physical chemistry chemical physics : PCCP.

[8]  R. Frahm New method for time dependent x-ray absorption studies , 1989 .

[9]  D. Lützenkirchen-Hecht,et al.  A new stand-alone QEXAFS data acquisition system for in situ studies. , 2011, Journal of synchrotron radiation.

[10]  R F Pettifer,et al.  The physics of ionization chambers - or how to improve your signal-to-noise ratio for transmission EXAFS measurements. , 1999, Journal of synchrotron radiation.

[11]  D. Wilkinson,et al.  Ionization chambers and counters , 1950 .

[12]  P. Nicolson Cambridge Monographs on Physics , 1950, Nature.

[13]  D. Lützenkirchen-Hecht,et al.  A new flexible monochromator setup for quick scanning x-ray absorption spectroscopy. , 2010, The Review of scientific instruments.

[14]  J. Grunwaldt,et al.  Oscillatory Behavior during the Catalytic Partial Oxidation of Methane: Following Dynamic Structural Changes of Palladium Using the QEXAFS Technique , 2012 .

[15]  J. Harvey,et al.  DESIGN OF GRID IONIZATION CHAMBERS , 1949 .