Increasing lead burden correlates with externalized cables during systematic fluoroscopic screening of Riata leads

[1]  H. Tanner,et al.  Prevalence of asymptomatic and electrically undetectable intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST implantable cardioverter-defibrillator leads. , 2013, International journal of cardiology.

[2]  R. Passman,et al.  Prevalence and Predictors of Cable Extrusion and Loss of Electrical Integrity with the Riata Defibrillator Lead , 2012, Journal of cardiovascular electrophysiology.

[3]  Christopher R. Ellis,et al.  High prevalence of insulation failure with externalized cables in St. Jude Medical Riata family ICD leads: fluoroscopic grading scale and correlation to extracted leads. , 2012, Heart rhythm.

[4]  M. Schalij,et al.  Update on Small‐Diameter Implantable Cardioverter‐Defibrillator Leads Performance , 2012, Pacing and clinical electrophysiology : PACE.

[5]  D. Leong,et al.  Unrecognized Failure of a Narrow Caliber Defibrillation Lead: The Role of Defibrillation Threshold Testing in Identifying an Unprotected Individual , 2012, Pacing and clinical electrophysiology : PACE.

[6]  R. Hauser,et al.  Riata implantable cardioverter-defibrillator lead failure: analysis of explanted leads with a unique insulation defect. , 2012, Heart rhythm.

[7]  J. Healey,et al.  Clinical Predictors of Fidelis Lead Failure: Report From the Canadian Heart Rhythm Society Device Committee , 2012, Circulation.

[8]  R. Hauser,et al.  Here we go again--another failure of postmarketing device surveillance. , 2012, The New England journal of medicine.

[9]  A. Brandt A reader's guide to 200 years of the New England Journal of Medicine. , 2012, The New England journal of medicine.

[10]  A. Yue,et al.  Is a New High‐Voltage Lead Necessary? 6.6‐French ICD Lead Failure: A UK Tertiary Center Experience , 2012, Pacing and clinical electrophysiology : PACE.

[11]  S. Hohnloser,et al.  Insulation Defects of Thin High‐Voltage ICD Leads: , 2011, Journal of cardiovascular electrophysiology.

[12]  H. Calkins,et al.  Premature Failure of a Riata Defibrillator Lead Without Impedance Change or Inappropriate Sensing: A Case Report and Review of the Literature , 2011, Journal of cardiovascular electrophysiology.

[13]  N. Derval,et al.  Unusual failure of a multilumen, small-diameter implantable cardioverter-defibrillator lead. , 2010, Heart rhythm.

[14]  C. Israel,et al.  Implantable cardioverter-defibrillator lead disintegration at the level of the tricuspid valve. , 2008, Heart rhythm.

[15]  A. Krahn,et al.  Complications associated with implantable cardioverter-defibrillator replacement in response to device advisories. , 2006, JAMA.

[16]  J. Brinker,et al.  Risks of spontaneous injury and extraction of an active fixation pacemaker lead: report of the Accufix Multicenter Clinical Study and Worldwide Registry. , 1999, Circulation.