Image quality and stability of image-guided radiotherapy (IGRT) devices: A comparative study.

INTRODUCTION Our aim was to implement standards for quality assurance of IGRT devices used in our department and to compare their performances with that of a CT simulator. MATERIALS AND METHODS We investigated image quality parameters for three devices over a period of 16months. A multislice CT was used as a benchmark and results related to noise, spatial resolution, low contrast visibility (LCV) and uniformity were compared with a cone beam CT (CBCT) at a linac and simulator. RESULTS All devices performed well in terms of LCV and, in fact, exceeded vendor specifications. MTF was comparable between CT and linac CBCT. Integral nonuniformity was, on average, 0.002 for the CT and 0.006 for the linac CBCT. Uniformity, LCV and MTF varied depending on the protocols used for the linac CBCT. Contrast-to-noise ratio was an average of 51% higher for the CT than for the linac and simulator CBCT. No significant time trend was observed and tolerance limits were implemented. DISCUSSION Reasonable differences in image quality between CT and CBCT were observed. Further research and development are necessary to increase image quality of commercially available CBCT devices in order for them to serve the needs for adaptive and/or online planning.

[1]  Peter Munro,et al.  A quality assurance program for the on-board imager®. , 2006, Medical physics.

[2]  Jan-Jakob Sonke,et al.  Automatic prostate localization on cone-beam CT scans for high precision image-guided radiotherapy. , 2005, International journal of radiation oncology, biology, physics.

[3]  D A Jaffray,et al.  A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets. , 1999, International journal of radiation oncology, biology, physics.

[4]  J H Siewerdsen,et al.  Cone-beam computed tomography with a flat-panel imager: effects of image lag. , 1999, Medical physics.

[5]  John Wong,et al.  Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients. , 2004, International journal of radiation oncology, biology, physics.

[6]  James A. Purdy,et al.  Commissioning experience with cone‐beam computed tomography for image‐guided radiation therapy , 2007, Journal of applied clinical medical physics.

[7]  J. Balter,et al.  Quality assurance for kilo- and megavoltage in-room imaging and localization for off- and online setup error correction. , 2008, International journal of radiation oncology, biology, physics.

[8]  David A Jaffray,et al.  Online planning and delivery technique for radiotherapy of spinal metastases using cone-beam CT: image quality and system performance. , 2007, International journal of radiation oncology, biology, physics.

[9]  D. Jaffray,et al.  The influence of bowtie filtration on cone-beam CT image quality , 2008 .

[10]  J R Sykes,et al.  Measurement of cone beam CT coincidence with megavoltage isocentre and image sharpness using the QUASAR Penta-Guide phantom. , 2008, Physics in medicine and biology.

[11]  J. Fowler,et al.  Image guidance for precise conformal radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[12]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[13]  Mark Oldham,et al.  Cone-beam-CT guided radiation therapy: A model for on-line application. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[14]  S. Nill,et al.  Linac-integrated kV-cone beam CT: technical features and first applications. , 2006, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[15]  Jan-Jakob Sonke,et al.  Adaptive radiotherapy for prostate cancer using kilovoltage cone-beam computed tomography: first clinical results. , 2008, International journal of radiation oncology, biology, physics.

[16]  Performance characteristics and quality assurance aspects of kilovoltage cone-beam CT on medical linear accelerator. , 2007, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[17]  David A Jaffray,et al.  A quality assurance program for image quality of cone-beam CT guidance in radiation therapy. , 2008, Medical physics.

[18]  Uwe Oelfke,et al.  A quantitative image quality comparison of four different image guided radiotherapy devices. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[19]  Patrick A Kupelian,et al.  Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unit. , 2005, Medical physics.

[20]  D. R. White,et al.  Evaluating performance characteristics in computerized tomography. , 1981, The British journal of radiology.

[21]  Kristy K Brock,et al.  Quality assurance of serial 3D image registration, fusion, and segmentation. , 2008, International journal of radiation oncology, biology, physics.