Transcutaneous Pco2 monitoring in critically ill adults: Clinical evaluation of a new sensor*

Objective:In critically ill patients, arterial blood gas analysis is the gold standard for evaluating systemic oxygenation and carbon dioxide partial pressure. A new miniaturized carbon dioxide tension Pco2-Spo2 single sensor (TOSCA, Linde Medical Sensors AG, Basel, Switzerland) continuously and noninvasively (transcutaneously) monitors both Paco2 and oxygen saturation by pulse oximetry (Spo2). The present study was designed to investigate the usability and the accuracy of this device in critically ill patients. Design:Prospective clinical investigation. Setting:A 20-bed, university-affiliated, surgical intensive care unit. Patients:Patients admitted after major surgery, multiple trauma, or septic shock equipped with an arterial catheter. Interventions:The heated (42°C) sensor was fixed at the earlobe using an attachment clip. Transcutaneous Pco2 (TcPco2) measurements were correlated with Paco2 values (measured using a blood gas analyzer). In addition, the differences between Paco2 and TcPco2 values were evaluated using the method of Bland-Altman. Measurements and Main Results:We studied 55 patients, aged 18–80 (mean 57 ± 15) yrs. A total of 417 paired measurements were compared. Correlation between TcPco2 and Paco2 was r = .86 (p < .01) in the Paco2 range of 24–101 mm Hg. Mean bias (±sd) between the two methods of measurement (Bland-Altman analysis) was 1.2 ± 6.0 mm Hg with TcPco2 slightly overestimating arterial carbon dioxide tension. Nineteen percent of the measured values were outside of the acceptable clinical range of agreement of ±7.5 mm Hg. Conclusions:The present study suggests that Paco2 can be acceptably assessed by measuring TcPco2 using the TOSCA Pco2-Spo2 sensor.

[1]  J. Scribante,et al.  Accuracy of pulse oximetry in pigmented patients. , 1996, South African medical journal = Suid-Afrikaanse tydskrif vir geneeskunde.

[2]  Peter Beelen,et al.  Use of a peripheral perfusion index derived from the pulse oximetry signal as a noninvasive indicator of perfusion , 2002, Critical care medicine.

[3]  Severinghaus Jw,et al.  Transcutaneous analysis of arterial PCO2. , 1982 .

[4]  Mahutte Ck,et al.  Evaluation of a single transcutaneous PO2-PCO2 sensor in adult patients. , 1984 .

[5]  P Garnerin,et al.  Linking guideline to regular feedback to increase appropriate requests for clinical tests: blood gas analysis in intensive care , 2001, BMJ : British Medical Journal.

[6]  D. Roberts,et al.  Control of blood gas measurements in intensive-care units , 1991, The Lancet.

[7]  R. Albert,et al.  Noninvasive monitoring of arterial blood gases. A report of the ACCP section on respiratory pathophysiology. , 1983, Chest.

[8]  Enzo Berardesca,et al.  Ethnic skin: overview of structure and function. , 2003, Journal of the American Academy of Dermatology.

[9]  J. Severinghaus,et al.  Transcutaneous analysis of arterial PCO2. , 1982, Medical instrumentation.

[10]  J. Murray,et al.  Blood gas analysis and critical care medicine. , 1998, American journal of respiratory and critical care medicine.

[11]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[12]  W. Mindt,et al.  Cutaneous blood gas monitoring in the adult , 1981, Critical care medicine.

[13]  W. Shoemaker,et al.  Transcutaneous PCO2 monitoring on adult patients in the ICU and the operating room , 1981, Critical care medicine.

[14]  W B Runciman,et al.  Potential errors in pulse oximetry III: Effects of interference, dyes, dyshaemoglobins and other pigments * , 1991, Anaesthesia.

[15]  C. Camargo,et al.  Effect of skin pigmentation on pulse oximetry accuracy in the emergency department. , 1998, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[16]  L. Rodrigues,et al.  Transcutaneous flow related variables measured in vivo: the effects of gender , 2001, BMC dermatology.

[17]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[18]  C. K. Mahutte,et al.  Evaluation of a single transcutaneous Po2-Pco2 sensor in adult patients , 1984, Critical care medicine.

[19]  R. Burd,et al.  Noninvasive Monitoring of Carbon Dioxide During Mechanical Ventilation in Older Children: End-Tidal Versus Transcutaneous Techniques , 2001, Anesthesia and analgesia.

[20]  G. Wahl,et al.  Comparison of noninvasive measurements of carbon dioxide tension during withdrawal from mechanical ventilation , 1987, Critical care medicine.

[21]  J. Costantino,et al.  Accuracy of end-tidal and transcutaneous PCO2 monitoring during sleep. , 1994, Chest.

[22]  J. Chevrolet,et al.  Transcutaneous PCO2 to monitor noninvasive mechanical ventilation in adults: assessment of a new transcutaneous PCO2 device. , 1998, Chest.

[23]  Roman Rohling,et al.  Clinical Investigation of a New Combined Pulse Oximetry and Carbon Dioxide Tension Sensor in Adult Anaesthesia , 2004, Journal of Clinical Monitoring and Computing.

[24]  M. Ramsay,et al.  Controlled Sedation with Alphaxalone-Alphadolone , 1974, British medical journal.

[25]  D. Spahn,et al.  Combining transcutaneous blood gas measurement and pulse oximetry. , 2002, Anesthesia and analgesia.