In vitro and in vivo corrosion of the novel magnesium alloy Mg–La–Nd–Zr: influence of the measurement technique and in vivo implant location
暂无分享,去创建一个
N Angrisani | N. Angrisani | J. Reifenrath | R Eifler | A. Weizbauer | J Reifenrath | A-K Marten | A Weizbauer | R. Eifler | A-K Marten
[1] Frank Witte,et al. Corrosion of magnesium alloy AZ31 screws is dependent on the implantation site , 2011 .
[2] Andrea Meyer-Lindenberg,et al. In Vivo Degradation Behavior of the Magnesium Alloy LANd442 in Rabbit Tibiae , 2011, Materials.
[3] R. Willumeit,et al. Optimization of Cell Adhesion on Mg Based Implant Materials by Pre-Incubation under Cell Culture Conditions , 2014, International journal of molecular sciences.
[4] Karl Ulrich Kainer,et al. Element distribution in the corrosion layer and cytotoxicity of alloy Mg-10Dy during in vitro biodegradation. , 2013, Acta biomaterialia.
[5] V. Balasubramanian,et al. Comparison of the corrosion behaviour of AZ31B magnesium alloy under immersion test and potentiodynamic polarization test in NaCl solution , 2014 .
[6] Henning Windhagen,et al. In Vivo Corrosion of Two Novel Magnesium Alloys ZEK100 and AX30 and Their Mechanical Suitability as Biodegradable Implants , 2011, Materials.
[7] Andrea Meyer-Lindenberg,et al. Degrading magnesium screws ZEK100: biomechanical testing, degradation analysis and soft-tissue biocompatibility in a rabbit model , 2013, Biomedical materials.
[8] C. Ceccarini,et al. pH as a determinant of cellular growth and contact inhibition. , 1971, Proceedings of the National Academy of Sciences of the United States of America.
[9] H. Haferkamp,et al. In vivo corrosion of four magnesium alloys and the associated bone response. , 2005, Biomaterials.
[10] Frank Witte,et al. In vitro and in vivo corrosion measurements of magnesium alloys. , 2006, Biomaterials.
[11] Andrea Meyer-Lindenberg,et al. Long-term in vivo degradation behaviour and biocompatibility of the magnesium alloy ZEK100 for use as a biodegradable bone implant. , 2013, Acta biomaterialia.
[12] T. Woodfield,et al. The in vitro and in vivo evaluation of the biocompatibility of Mg alloys , 2013, Biomedical materials.
[13] P. Uggowitzer,et al. In vivo degradation performance of micro-arc-oxidized magnesium implants: a micro-CT study in rats. , 2013, Acta biomaterialia.
[14] Henning Windhagen,et al. In vivo assessment of the host reactions to the biodegradation of the two novel magnesium alloys ZEK100 and AX30 in an animal model , 2012, Biomedical engineering online.
[15] Janine Fischer,et al. Improved cytotoxicity testing of magnesium materials , 2011 .
[16] G. Sjögren,et al. Cytotoxicity of dental alloys, metals, and ceramics assessed by millipore filter, agar overlay, and MTT tests. , 2000, The Journal of prosthetic dentistry.
[17] S. Stanzl-Tschegg,et al. Bone-implant interface strength and osseointegration: Biodegradable magnesium alloy versus standard titanium control. , 2011, Acta biomaterialia.
[18] E. Wintermantel,et al. Fibroblastic response and surface characterization of O2-plasma-treated thermoplastic polyetherurethane , 2010, Biomedical materials.
[19] Yang Song,et al. Research on an Mg-Zn alloy as a degradable biomaterial. , 2010, Acta biomaterialia.
[20] E. Willbold,et al. Biodegradation of a magnesium alloy implant in the intercondylar femoral notch showed an appropriate response to the synovial membrane in a rabbit model in vivo , 2014, Journal of biomaterials applications.
[21] Andrej Atrens,et al. Measurement of the corrosion rate of magnesium alloys using Tafel extrapolation , 2010 .
[22] Fritz Thorey,et al. Biomechanical testing and degradation analysis of MgCa0.8 alloy screws: a comparative in vivo study in rabbits. , 2011, Acta biomaterialia.
[23] J. Nellesen,et al. In vitro and in vivo evaluation of biodegradable, open-porous scaffolds made of sintered magnesium W4 short fibres. , 2013, Acta biomaterialia.
[24] P. Uggowitzer,et al. Magnesium alloys for temporary implants in osteosynthesis: in vivo studies of their degradation and interaction with bone. , 2012, Acta biomaterialia.
[25] Bryan E. Anderson,et al. The Netter Collection of medical illustrations , 1994 .
[26] H. Wong,et al. A biodegradable polymer-based coating to control the performance of magnesium alloy orthopaedic implants. , 2010, Biomaterials.
[27] F. Beckmann,et al. In vivo corrosion and corrosion protection of magnesium alloy LAE442. , 2010, Acta biomaterialia.
[28] Henning Windhagen,et al. Novel magnesium alloy Mg-2La caused no cytotoxic effects on cells in physiological conditions. , 2014, Materials science & engineering. C, Materials for biological applications.
[29] Frank Feyerabend,et al. Mg and Mg alloys: how comparable are in vitro and in vivo corrosion rates? A review. , 2015, Acta biomaterialia.
[30] Andrej Atrens,et al. The in vivo and in vitro corrosion of high-purity magnesium and magnesium alloys WZ21 and AZ91 , 2013 .
[31] J. Seitz,et al. Characterization of MgNd2 alloy for potential applications in bioresorbable implantable devices. , 2012, Acta biomaterialia.
[32] M. Gupta,et al. Insight into Designing Biocompatible Magnesium Alloys and Composites: Processing, Mechanical and Corrosion Characteristics , 2015 .
[33] J. Jacobs,et al. Zirconium and Niobium Affect Human Osteoblasts, Fibroblasts, and Lymphocytes in a Similar Manner to More Traditional Implant Alloy Metals , 2006 .
[34] J. Reifenrath,et al. Influence of the grain size on the in vivo degradation behaviour of the magnesium alloy LAE442 , 2013, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[35] Tim Woodfield,et al. Magnesium alloys: predicting in vivo corrosion with in vitro immersion testing. , 2012, Journal of biomedical materials research. Part B, Applied biomaterials.
[36] W. Tillmann,et al. Biocompatibility of rapidly solidified magnesium alloy RS66 as a temporary biodegradable metal. , 2013, Acta biomaterialia.