Aorta in vivo parameter identification using an axial force constraint

It was shown in a previous study by Stålhand et al. (2004) that both material and residual strain parameters for an artery can be identified noninvasively from an in vivo clinical pressure–diameter measurement. The only constraints placed on the model parameters in this previous study was a set of simple box constraints. More advanced constraints can also be utilized, however. These constraints restrict the model parameters implicitly by demanding the state of the artery to behave in a specified way. It has been observed in vitro that the axial force is nearly invariant to the pressure at the physiological operation point. In this paper, we study the possibility to include this behaviour as a constraint in the parameter optimization. The method is tested on an in vivo obtained pressure–diameter cycle for a 24-year-old human. Presented results show that the constrained parameter identification procedure proposed here can be used to obtain good results, and we believe that it may be applied to account for other observed behaviours as well.

[1]  K. Takamizawa,et al.  Strain energy density function and uniform strain hypothesis for arterial mechanics. , 1987, Journal of biomechanics.

[2]  Gerhard A. Holzapfel,et al.  Nonlinear Solid Mechanics: A Continuum Approach for Engineering Science , 2000 .

[3]  F. Plum Handbook of Physiology. , 1960 .

[4]  J. T. Shepherd,et al.  Peripheral circulation and organ blood flow , 1983 .

[5]  Y. Fung,et al.  Pseudoelasticity of arteries and the choice of its mathematical expression. , 1979, The American journal of physiology.

[6]  A. Klarbring,et al.  Towards in vivo aorta material identification and stress estimation , 2004, Biomechanics and modeling in mechanobiology.

[7]  Kozaburo Hayashi,et al.  Theoretical Study of the Effects of Vascular Smooth Muscle Contraction on Strain and Stress Distributions in Arteries , 1999, Annals of Biomedical Engineering.

[8]  Thomas D. Kampp,et al.  Passive Elastic Properties of the Rat Aorta. Passive elastische Eigenschaften der Aorta von Ratten , 1990 .

[9]  R. Ogden Non-Linear Elastic Deformations , 1984 .

[10]  B. Sonesson,et al.  Influence of sympathetic stimulation on the mechanical properties of the aorta in humans. , 1997, Acta physiologica Scandinavica.

[11]  R. N. Vaishnav,et al.  ESTIMATION OF RESIDUAL STRAINS IN AORTIC SEGMENTS , 1983 .

[12]  J. Humphrey Cardiovascular solid mechanics , 2002 .

[13]  G A Holzapfel,et al.  Determination of constitutive equations for human arteries from clinical data. , 2003, Journal of biomechanics.

[14]  B. Sonesson,et al.  Sex difference in the mechanical properties of the abdominal aorta in human beings. , 1994, Journal of vascular surgery.

[15]  R. Ogden,et al.  A New Constitutive Framework for Arterial Wall Mechanics and a Comparative Study of Material Models , 2000 .

[16]  Gerhard A Holzapfel,et al.  Passive biaxial mechanical response of aged human iliac arteries. , 2003, Journal of biomechanical engineering.

[17]  C. William Hall,et al.  Biomedical Engineering II Recent Developments , 1983 .

[18]  Keiichi Takamizawa,et al.  Kinematics for bodies undergoing residual stress and its applications to the left ventricle , 1990 .