Fabrication and modeling of uniform-waist single-mode tapered optical fiber sensors.

We report the fabrication and modeling of single-mode tapered optical fiber sensors. The fabrication technique consist of stretching a section of fiber with an oscillating flame torch. Such a process allows controllable fabrication of lossless tapered fibers with a uniform waist. The sensor transmittance is modeled with a simple ray optics approach. In the model, all the taper parameters are taken into account. Our results indicate that sensor sensitivity can be adjusted with the taper waist diameter. As an example a gold-coated tapered fiber is theoretically and experimentally analyzed.

[1]  Jose L. Cruz,et al.  In-line highly sensitive hydrogen sensor based on palladium-coated single-mode tapered fibers , 2003 .

[2]  S. Lacroix,et al.  Investigation of power oscillations along tapered monomode fibers. , 1987, Applied optics.

[3]  W. Henry Evanescent field devices: a comparison between tapered optical fibres and polished or D-fibres , 1994 .

[4]  P. M. Shankar,et al.  Bending effects in biconically tapered single-mode fibers , 1990 .

[5]  Timothy A. Birks,et al.  Control of optical fibre taper shape , 1991 .

[6]  Cylindrical metal-coated optical fibre devices for filters and sensors , 1996 .

[7]  R. Falciai,et al.  Biconically-tapered optical fiber probes for the measurement of esophageal pressure , 1998 .

[8]  Keith A. Nugent,et al.  Fabrication, modeling, and direct evanescent field measurement of tapered optical fiber sensors , 1999 .

[9]  Mehdi Shadaram,et al.  Modeling and performance evaluation of ferrocene-based polymer clad tapered optical fiber gas sensors , 1998 .

[10]  T. Birks,et al.  Shape of fiber tapers , 1992 .

[11]  B. Culshaw,et al.  Optical waveguide modelling and design for evanescent field chemical sensors , 1994 .

[12]  Singlemode optical fibre surface plasma wave chemical sensor , 1995 .

[13]  F. Arregui,et al.  Optical fiber humidity sensor based on a tapered fiber coated with agarose gel , 2000 .

[14]  Jose L. Cruz,et al.  Highly sensitive optical hydrogen sensor using circular Pd-coated singlemode tapered fibre , 2001 .

[15]  P M Shankar,et al.  Pressure sensor that uses bent biconically tapered single-mode fibers. , 1991, Optics letters.

[16]  John D. Love,et al.  Quantifying loss minimisation in single-mode fibre tapers , 1986 .

[17]  Jose L. Cruz,et al.  Hybrid surface plasma modes in circular metal-coated tapered fibers , 1999 .