Restricted single isocenter for multiple targets dynamic conformal arc (RSIMT DCA) technique for brain stereotactic radiosurgery (SRS) planning.

Purpose/Objectives In stereotactic radiosurgery (SRS), the multiple isocenters for multiple targets dynamic conformal arc (MIMT DCA) technique is traditionally used to treat multiple brain metastases, with one isocenter for each target. The single isocenter for multiple targets (SIMT) technique has recently been adopted to reduce the treatment time at the cost of plan quality. The objective of this study was to develop a restricted single isocenter for multiple targets DCA (RSIMT DCA) technique that can significantly reduce the treatment time but still maintain similar plan quality as the MIMT DCA technique. Materials and Methods Treating multiple brain metastases with a single isocenter poses a challenge to SRS planning using DCA beams that are intrinsically 3D and do not modulate the beam intensity to spare the normal tissue between targets. To address this obstacle, we have developed a RSIMT DCA technique and used it to treat SRS patients with multiple brain metastases since February 2015. This planning approach is similar to the SIMT technique except that the number of targets for each isocenter is restricted and the distance between the isocenter and target is limited. In this technique, the targets are first split into batches so that all targets in a batch are within a chosen distance (e.g., 7 cm) of each other. All targets in a batch are combined into one target and the geometric center of the combined target is the isocenter for the group of DCA beams associated with that batch. Each DCA group typically consists of 3-4 DCA beams to irradiate 1-3 targets. For each DCA beam, the collimator angle is adjusted to minimize the exposure of normal tissue between targets. The dose of each treatment group is normalized so that the maximal point dose to the combined target is 125% of the prescription dose, which is equivalent to normalize the prescription dose to 80% isodose line. If the maximal point dose of a target is <123%, an additional beam is used to boost the maximal point dose of that target to 125%. To evaluate the plan quality, we randomly selected 10 cases planned with the RSIMT DCA technique, and re-planned them using the MIMT DCA technique. There were in total 38 PTVs, and 22 isocenters were used to treat all of these targets. The prescription for each target was 20 Gy with a maximal point dose of 25 Gy. Plan quality indexes were calculated and compared. Paired sample t-test was performed to determine if the mean normalized difference, (RSIMT-MIMT)/MIMT of each plan index was statistically significantly (p-value < 5%) larger than 0. Results Satisfactory PTV coverage (V20Gy>95% and V19Gy=100%) was achieved for all plans using either technique. Most PTVs have a maximal point dose between 24.9 and 25.1 Gy, with 2 PTVs between 24.5 and 24.9 Gy. Overall, the plan quality was slightly better for the MIMT DCA technique and the normalized difference was statistically significantly larger than 0 for all investigated dose quality indexes. The normalized difference of body mean dose and conformity index (CI) between the RSIMT and MIMT techniques was respectively 4.2% (p=0.002) and 9.4% (p=0.001), indicating similar plan quality globally and in the high dose area. The difference was more pronounced for the mid-to-low dose spillage with the ratios of V12Gy and V10Gy/VPTV being 13.9% (p=3.8×10-6) and 14.9% (p=1.3×10-5), respectively. The treatment time was reduced by 30%-50% with the RSIMT DCA technique. Conclusion The RSIMT DCA technique can produce satisfactory SRS plans for treating multiple targets and can significantly reduce the treatment time.

[1]  K. Hess,et al.  Neurocognition in patients with brain metastases treated with radiosurgery or radiosurgery plus whole-brain irradiation: a randomised controlled trial. , 2009, The Lancet. Oncology.

[2]  Maria Werner-Wasik,et al.  Whole brain radiation therapy with or without stereotactic radiosurgery boost for patients with one to three brain metastases: phase III results of the RTOG 9508 randomised trial , 2004, The Lancet.

[3]  Volker W Stieber,et al.  Effect of Radiosurgery Alone vs Radiosurgery With Whole Brain Radiation Therapy on Cognitive Function in Patients With 1 to 3 Brain Metastases: A Randomized Clinical Trial. , 2016, JAMA.

[4]  Gary A. Ezzell,et al.  The spatial accuracy of two frameless, linear accelerator‐based systems for single‐isocenter, multitarget cranial radiosurgery , 2017, Journal of applied clinical medical physics.

[5]  R. Wurm,et al.  Dynamic arc radiosurgery and radiotherapy: commissioning and verification of dose distributions. , 2001, International journal of radiation oncology, biology, physics.

[6]  T. Solberg,et al.  Dynamic arc radiosurgery field shaping: a comparison with static field conformal and noncoplanar circular arcs. , 2001, International journal of radiation oncology, biology, physics.

[7]  Jinkoo Kim,et al.  Radiosurgery of multiple brain metastases with single-isocenter dynamic conformal arcs (SIDCA). , 2014, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  Margie Hunt,et al.  Effect of MLC leaf width and PTV margin on the treatment planning of intensity-modulated stereotactic radiosurgery (IMSRS) or radiotherapy (IMSRT). , 2009, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[9]  Fang-Fang Yin,et al.  Physics considerations for single-isocenter, volumetric modulated arc radiosurgery for treatment of multiple intracranial targets. , 2016, Practical radiation oncology.

[10]  H. Shirato,et al.  Stereotactic Radiosurgery With or Without Whole-Brain Radiotherapy for Brain Metastases: Secondary Analysis of the JROSG 99-1 Randomized Clinical Trial. , 2015, JAMA oncology.

[11]  D. Verellen,et al.  Evaluation of a dedicated brain metastases treatment planning optimization for radiosurgery: a new treatment paradigm? , 2016, Radiation oncology.

[12]  Anees Dhabaan,et al.  Single-Isocenter Multiple-Target Stereotactic Radiosurgery: Risk of Compromised Coverage. , 2015, International journal of radiation oncology, biology, physics.

[13]  B. Guthrie,et al.  Plan quality and treatment planning technique for single isocenter cranial radiosurgery with volumetric modulated arc therapy. , 2012, Practical radiation oncology.

[14]  Jenghwa Chang A statistical model for analyzing the rotational error of single isocenter for multiple targets technique , 2017, Medical physics.

[15]  R. Popple,et al.  Feasibility of single-isocenter volumetric modulated arc radiosurgery for treatment of multiple brain metastases. , 2010, International Journal of Radiation Oncology, Biology, Physics.

[16]  F. Yin,et al.  Is a single isocenter sufficient for volumetric modulated arc therapy radiosurgery when multiple itracranial metastases are spatially dispersed? , 2016, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[17]  Statistical Analysis of the Rotation Error for Single-Isocenter Technique , 2016 .