Positioning of electrode plane systematically influences EIT imaging

Up to now, the impact of electrode positioning on electrical impedance tomography (EIT) had not been systematically analyzed due to the lack of a reference method. The aim of the study was to determine the impact of electrode positioning on EIT imaging in spontaneously breathing subjects at different ventilation levels with our novel lung function measurement setup combining EIT and body plethysmography. EIT measurements were conducted in three transverse planes between the 3rd and 4th intercostal space (ICS), at the 5th ICS and between the 6th and 7th ICS (named as cranial, middle and caudal) on 12 healthy subjects. Pulmonary function tests were performed simultaneously by body plethysmography to determine functional residual capacity (FRC), vital capacity (VC), tidal volume (VT), expiratory reserve volume (ERV), and inspiratory reserve volume (IRV). Ratios of impedance changes and body plethysmographic volumes were calculated for every thorax plane (ΔIERV/ERV, ΔIVT/VT and ΔIIRV/IRV). In all measurements of a subject, FRC values and VC values differed ≤5%, which confirmed that subjects were breathing at comparable end-expiratory levels and with similar efforts. In the cranial thorax plane the normalized ΔIERV/ERV ratio in all subjects was significantly higher than the normalized ΔIIRV/IRV ratio whereas the opposite was found in the caudal chest plane. No significant difference between the two normalized ratios was found in the middle thoracic plane. Depending on electrode positioning, impedance to volume ratios may either increase or decrease in the same lung condition, which may lead to opposite clinical decisions.

[1]  Zhanqi Zhao,et al.  PEEP titration guided by ventilation homogeneity: a feasibility study using electrical impedance tomography , 2010, Critical care.

[2]  C. J. Kotre Electrical impedance tomography. , 1997, British Journal of Radiology.

[3]  Marcelo B. P. Amato,et al.  Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography , 2009, Intensive Care Medicine.

[4]  Steffen Leonhardt,et al.  Tidal recruitment assessed by electrical impedance tomography and computed tomography in a porcine model of lung injury* , 2012, Critical care medicine.

[5]  J. D. Munck,et al.  The electric resistivity of human tissues (100 Hz-10 MHz): a meta-analysis of review studies. , 1999, Physiological measurement.

[6]  M. Steinfath,et al.  Regional ventilation distribution determined by electrical impedance tomography: Reproducibility and effects of posture and chest plane , 2011, Respirology (Carlton South. Print).

[7]  Evaluation of a New Measurement System Combining Body Plethysmography and Electrical Impedance Tomography , 2013, Biomedizinische Technik. Biomedical engineering.

[8]  S. Leonhardt,et al.  Lung volume calculated from electrical impedance tomography in ICU patients at different PEEP levels , 2009, Intensive Care Medicine.

[9]  J. Bakker,et al.  Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial , 2011, Critical care.

[10]  A. Greenough,et al.  Prediction of prolonged ventilator dependence in children by respiratory function measurements , 1999, Physiological measurement.

[11]  Gerhard Hellige,et al.  Thoracic electrical impedance tomographic measurements during volume controlled ventilation-effects of tidal volume and positive end-expiratory pressure , 1999, IEEE Transactions on Medical Imaging.

[12]  Sanjay P. Prabhu,et al.  Mechanical Ventilation Guided by Electrical Impedance Tomography in Experimental Acute Lung Injury* , 2013, Critical care medicine.

[13]  G. Viegi,et al.  Standardisation of the measurement of lung volumes , 2005, European Respiratory Journal.

[14]  Dirk Schädler,et al.  Comparison of different methods to define regions of interest for evaluation of regional lung ventilation by EIT , 2006, Physiological measurement.

[15]  Christian Putensen,et al.  Electrical impedance tomography guided ventilation therapy , 2007, Current opinion in critical care.

[16]  Yue Xiu-li,et al.  Multifunctional magnetic nanoparticles for magnetic resonance image-guided photothermal therapy for cancer , 2014 .

[17]  J. Hankinson,et al.  Standardisation of spirometry , 2005, European Respiratory Journal.