ZnO Film Bulk Acoustic Resonator for the Kinetics Study of Human Blood Coagulation

Miniaturized and rapid blood coagulation assay technologies are critical in many clinical settings. In this paper, we present a ZnO film bulk acoustic resonator for the kinetic analysis of human blood coagulation. The resonator operated in thickness shear resonance mode at 1.4 GHz. When the resonator contacted the liquid environment, the viscous loading effect was considered as the additional resistance and inductance in the equivalent circuits, resulting in a linear relationship with a slope of approximately −217 kHz/cP between the liquid viscosity and the frequency of the resonator. The downshift of the resonant frequency and the viscosity change during the blood coagulation were correlated to monitor the coagulation process. The sigmoidal trend was observed in the frequency response for the blood samples activated by thromboplastin and calcium ions. The coagulation kinetics involving sequential phases of steady reaction, growth and saturation were revealed through the time-dependent frequency profiles. The enzymatic cascade time, the coagulation rate, the coagulation time and the clot degree were provided by fitting the time-frequency curves. The prothrombin times were compared with the results measured by a standard coagulometer and show a good correlation. Thanks to the excellent potential of integration, miniaturization and the availability of direct digital signals, the film bulk acoustic resonator has promising application for both clinical and personal use coagulation testing technologies.

[1]  Qiuquan Guo,et al.  Micro-electromechanical film bulk acoustic sensor for plasma and whole blood coagulation monitoring. , 2017, Biosensors & bioelectronics.

[2]  M. Hussain QCM-D for Haemostasis Assays: Current Status and Future: A Review , 2016 .

[3]  M. Benetti,et al.  Thin-Film Bulk-Acoustic-Resonator Gas Sensor Functionalized With a Nanocomposite Langmuir–Blodgett Layer of Carbon Nanotubes , 2008, IEEE Transactions on Electron Devices.

[4]  William I. Milne,et al.  Label-free detection of human prostate-specific antigen (hPSA) using film bulk acoustic resonators (FBARs) , 2014 .

[5]  Omar Elmazria,et al.  c-axis inclined AlN film growth in planar system for shear wave devices , 2008 .

[6]  Ute Klinkhardt,et al.  A novel μ-fluidic whole blood coagulation assay based on Rayleigh surface-acoustic waves as a point-of-care method to detect anticoagulants. , 2013, Biomicrofluidics.

[7]  Mark E. Thompson,et al.  A film bulk acoustic resonator in liquid environments , 2005 .

[8]  Jing Li,et al.  A novel region-based level set method initialized with mean shift clustering for automated medical image segmentation , 2013, Comput. Biol. Medicine.

[9]  Jingjing Wang,et al.  A micro-machined thin film electro-acoustic biosensor for detection of pesticide residuals , 2014, Journal of Zhejiang University SCIENCE C.

[10]  G Wingqvist,et al.  On the applicability of high frequency acoustic shear mode biosensing in view of thickness limitations set by the film resonance. , 2009, Biosensors & bioelectronics.

[11]  Christiane Ziegler,et al.  Investigation of prothrombin time in human whole-blood samples with a quartz crystal biosensor. , 2010, Analytical chemistry.

[12]  Junseok Chae,et al.  Real-Time Monitoring of Whole Blood Coagulation Using a Microfabricated Contour-Mode Film Bulk Acoustic Resonator , 2012, Journal of Microelectromechanical Systems.

[13]  A. J. Flewittb,et al.  Recent developments on ZnO films for acoustic wave based bio-sensing and microfluidic applications: a review , 2009 .

[14]  U. Mastromatteo,et al.  High sensitivity acoustic wave AlN/Si mass detectors arrays for artificial olfactory and biosensing applications: A review , 2013 .

[15]  Munawar Hussain,et al.  Shortened 'Thrombin Time' Monitoring on QCM-D: a better Substitute of 'Gold Standard' , 2016 .

[16]  Munawar Hussain,et al.  QCM-D providing new horizon in the domain of sensitivity range and information for haemostasis of human plasma. , 2015, Biosensors & bioelectronics.

[17]  Donald E Ingber,et al.  A shear gradient-activated microfluidic device for automated monitoring of whole blood haemostasis and platelet function , 2016, Nature Communications.

[18]  Jing Jing Wang,et al.  Hydrogen sensor based on Pd-functionalized film bulk acoustic resonator , 2011 .

[19]  Qingtian Zeng,et al.  Synchronization-Core-Based Discovery of Processes with Decomposable Cyclic Dependencies , 2016, ACM Trans. Knowl. Discov. Data.

[20]  Xiaotang Hu,et al.  Piezoelectric microelectromechanical resonant sensors for chemical and biological detection. , 2012, Lab on a chip.

[21]  Xin-Yue Li,et al.  Two families of Liouville integrable lattice equations , 2011, Appl. Math. Comput..

[22]  Hakan Urey,et al.  A cartridge based sensor array platform for multiple coagulation measurements from plasma. , 2015, Lab on a chip.

[23]  I. Katardjiev,et al.  FBAR Sensor Array for in Liquid Operation , 2010, IEEE Sensors Journal.

[24]  Hakan Urey,et al.  Microcantilever based disposable viscosity sensor for serum and blood plasma measurements. , 2013, Methods.

[25]  M. Hegner,et al.  Microrheological Coagulation Assay Exploiting Micromechanical Resonators. , 2017, Analytical chemistry.

[26]  Jingjing Wang,et al.  A pure shear mode ZnO film resonator for the detection of organophosphorous pesticides , 2012 .

[27]  Weihui Liu,et al.  Label-free immunosensor based on micromachined bulk acoustic resonator for the detection of trace pesticide residues , 2014 .

[28]  Ye Chang,et al.  Detection of Volatile Organic Compounds by Self-assembled Monolayer Coated Sensor Array with Concentration-independent Fingerprints , 2016, Scientific Reports.

[29]  Anthony J. Killard,et al.  Coagulation monitoring devices: Past, present, and future at the point of care , 2013 .

[30]  Peter A. Lieberzeit,et al.  Blood Coagulation Thromboplastine Time Measurements on a Nanoparticle Coated Quartz Crystal Microbalance Biosensor in Excellent Agreement with Standard Clinical Methods , 2013 .

[31]  M. Hussain PiCT: 1 st Recognition for Human Whole Blood on QCM-D Platform , 2015 .

[32]  Ilia Katardjiev,et al.  Recent developments in thin film electro-acoustic technology for biosensor applications , 2012 .

[33]  Munawar Hussain,et al.  'Argatroban' Monitoring in Human Plasma:aAPTT and PiCT Studies on QCM-D Vs 'Gold Standard' , 2015 .

[34]  Munawar Hussain,et al.  A Simultaneous Monitoring of Coagulation Time and Fibrinogen via PiCT on QCM-D , 2016 .

[35]  M. Schreiter,et al.  Sensing characteristics of high-frequency shear mode resonators in glycerol solutions , 2007 .

[36]  Kari Tukkiniemi,et al.  CMOS-Integrated Film Bulk Acoustic Resonators for Label-Free Biosensing , 2010, Sensors.

[37]  Ventsislav Yantchev,et al.  Shear mode AlN thin film electro-acoustic resonant sensor operation in viscous media , 2007 .

[38]  A. Mortazawi,et al.  An Intrinsically Switchable Ladder-Type Ferroelectric BST-on-Si Composite FBAR Filter , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.