High-resolution transmission measurements of CO2 at high temperatures for industrial applications

Abstract High-resolution transmission spectra of CO2 in the 2.7, 4.3 and 15 μm regions at temperatures up to 1773 K and at approximately atmospheric pressure (1.00±0.01 atm) are measured and compared with line-by-line calculations based on the HITEMP-1995, HITEMP-2010, CDSD-HITEMP and CDSD-4000 databases. The spectra have been recorded in a high-temperature flow gas cell and using a Fourier transform infrared (FTIR) spectrometer at a nominal resolution of 0.125 cm−1. The volume fractions of CO2 in the measurements were 1, 10 and 100%. The measurements have been validated by comparison with medium-resolution data obtained by Bharadwaj and Modest [6] . The deviations between the experimental spectra and the calculations at 1773 K and the vibrational energy exchange and thermal dissociation of CO2 at high temperatures are discussed.

[1]  Xiaoming Gao,et al.  Diode laser measurement of line strengths and air-broadening coefficients of CO2 and CO in the 1.57 μm region for combustion diagnostics , 2010 .

[2]  Sønnik Clausen,et al.  In situ Gas Temperature Measurements by UV-Absorption Spectroscopy , 2009 .

[3]  Hartmut Spliethoff,et al.  Validation of spectral gas radiation models under oxyfuel conditions. Part A: Gas cell experiments , 2011 .

[4]  D. Bailly 12C16O2: A Set of Spectroscopic Constants from a Simultaneous Treatment of Rovibrational Bands at 4.5 and 15 μM , 1994 .

[5]  Laurence S. Rothman,et al.  HITRAN HAWKS and HITEMP: high-temperature molecular database , 1995, Defense, Security, and Sensing.

[6]  M. Modest,et al.  Medium resolution transmission measurements of CO2 at high temperature , 2002 .

[7]  E. Shuryak Nonlinear resonance in quantum systems , 1976 .

[8]  S. Tashkun,et al.  CDSD-4000: High-resolution, high-temperature carbon dioxide spectroscopic databank , 2011 .

[9]  S. Tashkun,et al.  CDSD-1000, the high-temperature carbon dioxide spectroscopic databank , 2003 .

[10]  Sønnik Clausen,et al.  FTIR emission spectroscopy methods and procedures for real time quantitative gas analysis in industrial environments , 2002 .

[11]  Sudarshan P. Bharadwaj,et al.  Medium resolution transmission measurements of CO2 at high temperature—an update , 2007 .

[12]  P. Morrison,et al.  Calculation of Gas Spectra for Quantitative Fourier Transform Infrared Spectroscopy of Chemical Vapor Deposition , 1998 .

[13]  Jonathan Tennyson,et al.  HITEMP, the high-temperature molecular spectroscopic database , 2010 .

[14]  A. Fridman,et al.  Plasma Physics and Engineering , 2021 .

[15]  Philippe Rivière,et al.  Infrared emission spectroscopy of CO2 at high temperature. Part II: Experimental results and comparisons with spectroscopic databases , 2012 .

[16]  A. Soufiani,et al.  Infrared emission spectroscopy of CO2 at high temperature. Part I: Experimental setup and source characterization , 2012 .