Dove: Shoulder-Based Opioid Overdose Detection and Reversal Device

Naloxone is a life-saving drug capable of reversing a fatal opioid overdose. Although this drug has existed for over 50 years, opioid overdose-related deaths have consistently risen and surpassed 120,000 globally in 2021. Opioids induce respiratory depression by activating $\mu\text{-opioid}$ receptors at specific sites in the central nervous system. This results in overdose deaths caused by slow and shallow breathing, also known as opioid-induced respiratory depression. 1.6 million individuals suffer from opioid use disorder annually, making them at high risk of overdose, primarily due to the increasing prevalence of Fentanyl. Over 52% of these deaths occur when the individual is alone. Immediate response to an overdose by delivering naloxone can save the individual's life. To solve this problem, we developed a closed-loop sensor-driven auto-injector that can determine a fatal overdose and inject naloxone. 76% of this population is willing to wear such a device on the shoulder, a canonical injection site. This paper presents the DOVE, a shoulder-based opioid overdose detection and reversal device. It noninvasively measures the subject's motion state and changes in blood oxygen levels (SpO2) along with the respiration state. These biomarkers are measured from the shoulder using an optical sensor and accelerometer to determine if a fatal overdose occurred. We evaluated our DOVE device against an FDA-cleared commercial pulse oximeter by inducing apneic events as they have very similar SpO2 trends to an overdose. Results show that SpO2 can be measured on the shoulder across different skin tones with an accuracy of 96.8% and a high Pearson correlation of 0.766 (p < 0.0001).

[1]  Huanyu Cheng,et al.  Wearable Pressure Sensors Based on MXene/Tissue Papers for Wirelessly Human Health Monitoring. , 2021, ACS applied materials & interfaces.

[2]  M. S. Imtiaz,et al.  Hypoxia driven opioid targeted automated device for overdose rescue , 2021, Scientific Reports.

[3]  Jacob E. Sunshine,et al.  Closed-loop wearable naloxone injector system , 2021, Scientific Reports.

[4]  A. Kaye,et al.  Pharmacologic and Clinical Considerations of Nalmefene, a Long Duration Opioid Antagonist, in Opioid Overdose , 2021, Psychiatry International.

[5]  Stephen E. Lankenau,et al.  Wearable biosensors have the potential to monitor physiological changes associated with opioid overdose among people who use drugs: A proof-of-concept study in a real-world setting. , 2021, Drug and alcohol dependence.

[6]  Brittany P. Chapman,et al.  Nobody Wants to Be Narcan’d: A Pilot Qualitative Analysis of Drug Users’ Perspectives on Naloxone , 2021, The western journal of emergency medicine.

[7]  James Weimer,et al.  Willingness to use a wearable device capable of detecting and reversing overdose among people who use opioids in Philadelphia , 2021, Harm Reduction Journal.

[8]  Ketra L. Rice,et al.  The economic burden of opioid use disorder and fatal opioid overdose in the United States, 2017. , 2020, Drug and alcohol dependence.

[9]  C. Ngaruiya,et al.  Identifying homeless population needs in the Emergency Department using Community-Based Participatory Research , 2020, BMC Health Services Research.

[10]  R. Horton,et al.  The emergence of heat and humidity too severe for human tolerance , 2020, Science Advances.

[11]  Roderick R. Kunz,et al.  Chemical sensing via a low SWaP wearable spectrometer , 2020, Defense + Commercial Sensing.

[12]  Nicole M. Acquisto,et al.  Effect of Extreme Temperature on Naloxone Nasal Spray Dispensing Device Performance , 2020, Prehospital and Disaster Medicine.

[13]  P. Seth,et al.  Drug and Opioid-Involved Overdose Deaths — United States, 2017–2018 , 2020, MMWR. Morbidity and mortality weekly report.

[14]  Lauren M. Huyett,et al.  Safety and Performance of the Omnipod Hybrid Closed-Loop System in Adults, Adolescents, and Children with Type 1 Diabetes Over 5 Days Under Free-Living Conditions , 2020, Diabetes technology & therapeutics.

[15]  Xiao Hu,et al.  Photoplethysmography based atrial fibrillation detection: a review , 2020, npj Digital Medicine.

[16]  S. Shoptaw,et al.  Association between homelessness and opioid overdose and opioid-related hospital admissions/emergency department visits. , 2019, Social science & medicine.

[17]  Daniel Erlacher,et al.  Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor , 2019, Journal of biomedical optics.

[18]  P. Dietze,et al.  Effect of Intranasal vs Intramuscular Naloxone on Opioid Overdose , 2019, JAMA network open.

[19]  Min Ku Kim,et al.  Simple minimally-invasive automatic antidote delivery device (A2D2) towards closed-loop reversal of opioid overdose. , 2019, Journal of controlled release : official journal of the Controlled Release Society.

[20]  D. Reingardienė,et al.  Opioid Overdose , 2019, The APRN and PA’s Complete Guide to Prescribing Drug Therapy.

[21]  Ganesh R. Naik,et al.  A Comparison of Reflective Photoplethysmography for Detection of Heart Rate, Blood Oxygen Saturation, and Respiration Rate at Various Anatomical Locations , 2019, Sensors.

[22]  Toshiyo Tamura,et al.  Current progress of photoplethysmography and SPO2 for health monitoring , 2019, Biomedical Engineering Letters.

[23]  Shyamnath Gollakota,et al.  Opioid overdose detection using smartphones , 2019, Science Translational Medicine.

[24]  Hadi Kharrazi,et al.  Healthcare costs and utilization associated with high-risk prescription opioid use: a retrospective cohort study , 2018, BMC Medicine.

[25]  Rabab Ward,et al.  An optimal filter for short photoplethysmogram signals , 2018, Scientific Data.

[26]  B. Lloyd,et al.  Pharmaceutical opioid overdose deaths and the presence of witnesses. , 2018, The International journal on drug policy.

[27]  Chris J McManus,et al.  Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise , 2018, Journal of biomedical optics.

[28]  Premananda Indic,et al.  Wearable Biosensors to Evaluate Recurrent Opioid Toxicity After Naloxone Administration: A Hilbert Transform Approach , 2018, HICSS.

[29]  J. Soar,et al.  BTS guideline for oxygen use in adults in healthcare and emergency settings , 2017, Thorax.

[30]  J. Eian,et al.  Wearable Pulse Oximetry Measurements on the Torso, Arms, and Legs: A Proof of Concept. , 2017, Military medicine.

[31]  C. Farah,et al.  Thoracic Society of Australia and New Zealand oxygen guidelines for acute oxygen use in adults: ‘Swimming between the flags’ , 2015, Respirology.

[32]  Vijander Singh,et al.  Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy , 2015, Biomed. Signal Process. Control..

[33]  H. Linnebjerg,et al.  Subcutaneous Injection Depth Does Not Affect the Pharmacokinetics or Glucodynamics of Insulin Lispro in Normal Weight or Healthy Obese Subjects , 2015, Journal of diabetes science and technology.

[34]  Meir Nitzan,et al.  Pulse oximetry: fundamentals and technology update , 2014, Medical devices.

[35]  Toshiyo Tamura,et al.  Wearable Photoplethysmographic Sensors—Past and Present , 2014 .

[36]  N. Sriraam,et al.  The effect of temperature on the reliability of electronic components , 2014, 2014 IEEE International Conference on Electronics, Computing and Communication Technologies (CONECCT).

[37]  S. Quan,et al.  Rules for scoring respiratory events in sleep: update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine. , 2012, Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine.

[38]  Edward W Boyer,et al.  Management of opioid analgesic overdose. , 2012, The New England journal of medicine.

[39]  James McLaughlin,et al.  Blood oxygen level measurement with a chest-based Pulse Oximetry prototype system , 2010, 2010 Computing in Cardiology.

[40]  Ramesh Govindan,et al.  Sensor faults: Detection methods and prevalence in real-world datasets , 2010, TOSN.

[41]  C. Kirkpatrick,et al.  Population Pharmacokinetics of Intravenous, Intramuscular, and Intranasal Naloxone in Human Volunteers , 2008, Therapeutic drug monitoring.

[42]  P. Mannheimer,et al.  The Light–Tissue Interaction of Pulse Oximetry , 2007, Anesthesia and analgesia.

[43]  L. Nilsson,et al.  Combined photoplethysmographic monitoring of respiration rate and pulse: a comparison between different measurement sites in spontaneously breathing subjects , 2007, Acta anaesthesiologica Scandinavica.

[44]  John Allen Photoplethysmography and its application in clinical physiological measurement , 2007, Physiological measurement.

[45]  A. Kelly,et al.  Randomised trial of intranasal versus intramuscular naloxone in prehospital treatment for suspected opioid overdose , 2005, The Medical journal of Australia.

[46]  J. Christenson,et al.  Intravenous vs subcutaneous naloxone for out-of-hospital management of presumed opioid overdose. , 1998, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[47]  S. Waters,et al.  Duration of opioid antagonism by nalmefene and naloxone in the dog: an integrated pharmacokinetic/pharmacodynamic comparison. , 1995, Journal of pharmaceutical sciences.

[48]  A. C. M. Dassel,et al.  Reflectance pulse oximetry at the forehead improves by pressure on the probe , 1995, Journal of Clinical Monitoring.

[49]  L. Smith,et al.  Comparison of Potency and Duration of Action of Nalmefene and Naloxone , 1991, Anesthesia and analgesia.

[50]  Lynn W. Jelinski,et al.  Nuclear magnetic resonance spectroscopy. , 1990, Analytical chemistry.

[51]  E. Picetti,et al.  Management of opioid analgesic overdose. , 2012, New England Journal of Medicine.

[52]  Y. Mendelson,et al.  A Wearable Reflectance Pulse Oximeter for Remote Physiological Monitoring , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[53]  L. Yadav Ultraviolet (UV) and Visible Spectroscopy , 2005 .

[54]  L. Tarassenko,et al.  The effect of varying LED intensity on pulse oximeter accuracy. , 1991, Journal of medical engineering & technology.

[55]  K. Tremper,et al.  Pulse oximetry. , 1989, Anesthesiology.