Development of test facility for transmission line protection

Protection and metering of a feeder has a crucial role in power systems in terms of protecting the equipments from fault caused damage. A dedicated test facility was developed which generates high voltage and high current signals with the actual magnitudes. The facility can be used for distance protection, protection and metering applications in laboratory rather than using computer generated signals. Protection equipments of a current transformer, a potential transformer and a feeder management relay was used in order to test the facility. A series of actual fault records were analyzed and typical faults for transmission line were regenerated. According to the test results, designated test facility can be used to reproduce high voltages and currents signals, and to investigate the performance of different brands and types of instrument transformers and relays in laboratory.

[1]  Peter Crossley,et al.  Design and evaluation of a circulating current differential relay test system , 1998 .

[2]  O. P. Malik,et al.  Implementation and laboratory test results of an Elman network-based transmission line directional relay , 1999 .

[3]  Mike Aucoin,et al.  Feeder Protection and Monitoring System, Part II: Staged Fault Test Demonstration , 1985, IEEE Transactions on Power Apparatus and Systems.

[4]  M. S. Sachdev,et al.  A new microprocessor-based relay for transmission line protection , 1991, [Proceedings] WESCANEX '91.

[5]  Om P. Malik,et al.  Experimental test results for a parallel transmission lines protection scheme using wavelet transform , 2004 .

[6]  David Thomas,et al.  Voltage and current phasor estimation during abnormal conditions for transmission line protection schemes , 1997 .

[7]  B. Jeyasurya,et al.  Simulation of transmission line fault locators in a personal computer , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[8]  P. Bastard,et al.  Fundamental basis for distance relaying with parametrical estimation , 2000 .

[9]  O.P. Malik,et al.  Laboratory investigation of a distance-protection technique for double circuit lines , 2004, IEEE Transactions on Power Delivery.

[10]  M. Kezunovic,et al.  Impact of Optical Instrument Transformer Characteristics on the Performance of Protective Relays and Power Quality Meters , 2006, 2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America.

[11]  Lj.A. Kojovic Impact of current transformer saturation on overcurrent protection operation , 2002, IEEE Power Engineering Society Summer Meeting,.

[12]  G.G. Karady,et al.  A single-phase voltage sag generator for testing electrical equipments , 2008, 2008 IEEE/PES Transmission and Distribution Conference and Exposition.

[13]  Kazuo Nakada,et al.  Experimental Facility for Investigation of Lightning Performance of Distribution Lines , 2002, IEEE Power Engineering Review.

[14]  S. Singhal The role of metering in revenue protection , 1999 .