Filtration Performance of NIOSH-Approved N95 and P100 Filtering Facepiece Respirators Against 4 to 30 Nanometer-Size Nanoparticles

This study investigated the filtration performance of NIOSH-approved N95 and P100 filtering facepiece respirators (FFR) against six different monodisperse silver aerosol particles in the range of 4–30 nm diameter. A particle test system was developed and standardized for measuring the penetration of monodisperse silver particles. For respirator testing, five models of N95 and two models of P100 filtering facepiece respirators were challenged with monodisperse silver aerosol particles of 4, 8, 12, 16, 20, and 30 nm at 85 L/min flow rate and percentage penetrations were measured. Consistent with single-fiber filtration theory, N95 and P100 respirators challenged with silver monodisperse particles showed a decrease in percentage penetration with a decrease in particle diameter down to 4 nm. Penetrations less than 1 particle/30 min for 4–8 nm particles for one P100 respirator model, and 4–12 nm particles for the other P100 model, were observed. Experiments were also carried out with larger than 20 nm monodisperse NaCl particles using a TSI 3160 Fractional Efficiency Tester. NaCl aerosol penetration levels of 20 nm and 30 nm (overlapping sizes) particles were compared with silver aerosols of the same sizes by a three-way ANOVA analysis. A significant (p < 0.001) difference between NaCl and silver aerosol penetration levels was obtained after adjusting for particle sizes and manufacturers. A significant (p = 0.001) interaction with manufacturers indicated the difference in NaCl, and silver aerosol penetrations were not the same across manufacturers. The two aerosols had the same effect across 20 nm and 30 nm sizes as shown by the absence of any significant (p = 0.163) interaction with particle sizes. In the case of P100 FFRs, a significant (p < 0.001) difference between NaCl and silver aerosol (20 nm and 30 nm) penetrations was observed for both respirator models tested. The filtration data for 4–30 nm monodisperse particles supports previous studies that indicate NIOSH-approved air-purifying respirators provide expected levels of filtration protection against nanoparticles.

[1]  Sheng-Hsiu Huang,et al.  Penetration of 4.5nm to aerosol particles through fibrous filters , 2007 .

[2]  D. Pui,et al.  Experimental study of nanoparticles penetration through commercial filter media , 2006 .

[3]  Tiina Reponen,et al.  Respiratory Protection Provided by N95 Filtering Facepiece Respirators Against Airborne Dust and Microorganisms in Agricultural Farms , 2005, Journal of occupational and environmental hygiene.

[4]  Ziqing Zhuang,et al.  Respiratory protection against bioaerosols: Literature review and research needs , 2004, American Journal of Infection Control.

[5]  E. Moyer,et al.  Electrostatic respirator filter media: filter efficiency and most penetrating particle size effects. , 2000, Applied occupational and environmental hygiene.

[6]  K. Okuyama,et al.  Filtration efficiency of a fibrous filter for nanoparticles , 2006 .

[7]  Mark Nicas,et al.  Respiratory Protection Against Mycobacterium tuberculosis: Quantitative Fit Test Outcomes for Five Type N95 Filtering-Facepiece Respirators , 2004, Journal of occupational and environmental hygiene.

[8]  Jörg Meyer,et al.  Filtration Efficiency of Aerosol Particles Below 20 Nanometers , 2005 .

[9]  K. W. Lee,et al.  On the Minimum Efficiency and the Most Penetrating Particle Size for Fibrous Filters , 1980 .

[10]  Ali S Khan,et al.  Hantavirus pulmonary syndrome - United States: Updated recommendations for risk reduction , 2002 .

[11]  이수정 해외산업간호정보 - 미국 산업안전보건연구원(National Institute for Occupational Safety and Health) 소개 , 2009 .

[12]  Hwa-Chi Wang,et al.  Filtration efficiency of nanometer-size aerosol particles , 1991 .

[13]  Tiina Reponen,et al.  Do N95 respirators provide 95% protection level against airborne viruses, and how adequate are surgical masks? , 2006, American journal of infection control.

[14]  Barton Dahneke,et al.  The capture of aerosol particles by surfaces , 1971 .

[15]  C C Coffey,et al.  Performance of N95 respirators: filtration efficiency for airborne microbial and inert particles. , 1998, American Industrial Hygiene Association journal.

[16]  David Y. H. Pui,et al.  Experimental Study of Submicrometer and Ultrafine Particle Penetration and Pressure Drop for High Efficiency Filters , 1990 .

[17]  Samy Rengasamy Nanoparticle Penetration through NIOSH-Approved N95 Filtering-facepiece Respirators , 2007 .

[18]  A. Maynard,et al.  Airborne Nanostructured Particles and Occupational Health , 2005 .

[19]  Tiina Reponen,et al.  Manikin-based performance evaluation of N95 filtering-facepiece respirators challenged with nanoparticles. , 2006, The Annals of occupational hygiene.

[20]  T. Reponen,et al.  What Does Respirator Certification Tell Us About Filtration of Ultrafine Particles? , 2008, Journal of occupational and environmental hygiene.

[21]  C. Chen,et al.  279. Penetration of 4.5 nm to 10 IM Aerosol Particles through Fibrous Filters , 2006 .

[22]  A. Podǵorski,et al.  FILTRATION OF NANOSIZED AEROSOL PARTICLES IN FIBROUS FILTERS. I – EXPERIMENTAL RESULTS , 2004 .

[24]  Hwa-Chi Wang Comparison of Thermal Rebound Theory With Penetration Measurements of Nanometer Particles Through Wire Screens , 1996 .