Influence of calculation model on dose distribution in stereotactic radiotherapy for pulmonary targets.

PURPOSE To compare the pencil beam (PB) and collapsed cone (CC)-based three-dimensional dose calculation used for stereotactic irradiation of pulmonary targets. METHODS AND MATERIALS Three-dimensional conformal dose distributions (using 6-MV and 18-MV photon beams) were generated for 33 pulmonary targets using the PB algorithm implemented in the Helax-TMS treatment planning system and then recalculated with the CC algorithm of TMS using an identical beam setup and parameters. The differences were analyzed by evaluating the dose-volume histograms for the planning target volume (PTV) and clinical target volume (CTV) and evaluating the computed absolute monitor units (MUs). The influence of the photon energy was also studied. For three cases, the results were compared with Monte-Carlo calculations. RESULTS Use of the CC model typically showed increased dose inhomogeneity. Owing to a more accurate modeling of secondary charged particle disequilibrium at the tumor-lung interface, the beam penumbra is broadened. The median and mean target dose decreased by 13.9% and 11.2% for the PTV and 9.2% and 9.4% for the CTV, respectively, using the CC algorithm. Consequently, the average PTV dose coverage decreased by 7.1% (SD, 6.5%). On average, the MUs calculated to achieve the prescribed dose were 5.4% (SD, 5.8%) greater for the CC algorithm. The difference in MUs between the PB and CC increased with decreasing PTV size and high photon energy (18 MV; r = -0.68), reaching 26% at the maximum. CONCLUSION The absorbed dose at the lung-tumor interface calculated by the PB algorithm was considerably greater than the dose calculated using the CC algorithm. In small targets (PTV < or = 100 cm(3)) and for 18-MV photons, the MUs calculated with PB may lead to an insufficient dose to the target volume.

[1]  I. Lax Target dose versus extratarget dose in stereotactic radiosurgery. , 1993, Acta oncologica.

[2]  M. Fippel Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm. , 1999, Medical physics.

[3]  Takashi Aruga,et al.  Stereotactic single high dose irradiation of lung tumors under respiratory gating. , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[4]  F. Nüsslin,et al.  Experimental investigation of a fast Monte Carlo photon beam dose calculation algorithm. , 1999, Physics in medicine and biology.

[5]  M Engelsman,et al.  Impact of simple tissue inhomogeneity correction algorithms on conformal radiotherapy of lung tumours. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[6]  K Nakagawa,et al.  Megavoltage CT-assisted stereotactic radiosurgery for thoracic tumors: original research in the treatment of thoracic neoplasms. , 2000, International journal of radiation oncology, biology, physics.

[7]  Y. Shibamoto,et al.  Clinical outcomes of 3D conformal hypofractionated single high-dose radiotherapy for one or two lung tumors using a stereotactic body frame. , 2001, International journal of radiation oncology, biology, physics.

[8]  H Palmans,et al.  Underdosage of the upper-airway mucosa for small fields as used in intensity-modulated radiation therapy: a comparison between radiochromic film measurements, Monte Carlo simulations, and collapsed cone convolution calculations. , 2002, Medical physics.

[9]  A. Ahnesjö,et al.  A pencil beam model for photon dose calculation. , 1992, Medical physics.

[10]  I. Lax,et al.  2175 Radiosurgery for tumors in the body , 1997 .

[11]  Matthias Fippel,et al.  Verifikation eines schnellen Monte-Carlo-Dosis-berechnungsverfahrens durch EGSnrc anhand der statistischen Separationsmethode , 2001 .

[12]  Shinichi Shimizu,et al.  Tolerance of organs at risk in small-volume, hypofractionated, image-guided radiotherapy for primary and metastatic lung cancers. , 2003, International journal of radiation oncology, biology, physics.

[13]  D. Verellen,et al.  Evaluation of dose calculation algorithms for dynamic arc treatments of head and neck tumors. , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[14]  F. Lohr,et al.  Stereotactic single-dose radiation therapy of liver tumors: results of a phase I/II trial. , 2001, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[15]  I. Lax,et al.  Radiosurgery for Tumors in the Body: Clinical Experience Using a New Method , 1998 .

[16]  D. Verellen,et al.  Initial experience with intensity-modulated conformal radiation therapy for treatment of the head and neck region. , 1997, International journal of radiation oncology, biology, physics.

[17]  Michael Flentje,et al.  Impact of target reproducibility on tumor dose in stereotactic radiotherapy of targets in the lung and liver. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[18]  Michael Flentje,et al.  Stereotactic Radiotherapy of Targets in the Lung and Liver , 2001, Strahlentherapie und Onkologie.

[19]  S. Cora,et al.  Photon dose calculation of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM. , 2000, Medical physics.

[20]  Joseph R. Butts,et al.  Comparison of commercially available three‐dimensional treatment planning algorithms for monitor unit calculations in the presence of heterogeneities , 2001, Journal of applied clinical medical physics.

[21]  I. Lax,et al.  Extracranial Stereotactic Radiosurgery of Localized Targets , 1998 .

[22]  Douglas L. Jones ICRU Report 50—Prescribing, Recording and Reporting Photon Beam Therapy , 1994 .

[23]  U Oppitz,et al.  Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereotactic body frame. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[24]  P. Metcalfe,et al.  Verification of lung dose in an anthropomorphic phantom calculated by the collapsed cone convolution method. , 2000, Physics in medicine and biology.

[25]  J. Wong,et al.  Computed tomography-guided frameless stereotactic radiotherapy for stage I non-small cell lung cancer: a 5-year experience. , 2001, International journal of radiation oncology, biology, physics.

[26]  Tatsuya Fujisaki,et al.  Dose distribution of narrow beam irradiation for small lung tumor. , 2002, International journal of radiation oncology, biology, physics.

[27]  I. Lax,et al.  Stereotactic Radiotherapy of Extracranial Targets , 1994 .

[28]  Angelika Hoess,et al.  Stereotactic single-dose radiotherapy of stage I non-small-cell lung cancer (NSCLC). , 2003, International journal of radiation oncology, biology, physics.

[29]  T Knöös,et al.  Limitations of a pencil beam approach to photon dose calculations in lung tissue. , 1995, Physics in medicine and biology.

[30]  A. Ahnesjö Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media. , 1989, Medical physics.

[31]  Extracranial stereotactic radiotherapy: evaluation of PTV coverage and dose conformity. , 2002, Zeitschrift fur medizinische Physik.

[32]  Stephanie Frost,et al.  Extracranial stereotactic radioablation: results of a phase I study in medically inoperable stage I non-small cell lung cancer. , 2003, Chest.