Analysis of squeaking on ceramic hip endoprosthesis using the complex eigenvalue method

Abstract A finite element model of the ceramic hip endoprosthesis system is established with ABAQUS 6.7. The generation mechanism of squeaking is studied using the complex eigenvalue method which allows for a stability analysis of the system under friction coupling. Numerical results reveal that a ceramic hip endoprosthesis system has a strong propensity of unstable vibration when the friction coefficient of ceramic bearings reaches to a critical value, which is considered to be the most likely mechanism for squeaking. In the present study μ = 0.15 is proved to be a critical value, below which there is no instability of the system. Furthermore, the resonance of the femoral components at a frequency of 3177 Hz is found to be the source of the unstable vibration in squeaking. On the basis of the etiology of squeaking, two methods for suppressing squeaking are proposed. One method is adding ultra-high molecular weight polyethylene (UHMWPE) damping material in acetabular components, the other is imposing reasonable fixed stiffness on acetabular components. Simulation results show that both methods are effective for increasing the critical friction coefficient from 0.15 to 0.22 and 0.32, respectively, which improve the stability of the ceramic hip endoprosthesis system to a great extent.

[1]  J. Chang,et al.  Third-generation ceramic-on-ceramic bearing surfaces in revision total hip arthroplasty. , 2009, The Journal of arthroplasty.

[2]  E. Pyburn,et al.  Finite element analysis of femoral components paper III: hip joints , 2004 .

[3]  Huajiang Ouyang,et al.  Numerical analysis of automotive disc brake squeal: a review , 2005 .

[4]  P. Boutin,et al.  [Total arthroplasty of the hip by fritted aluminum prosthesis. Experimental study and 1st clinical applications]. , 1972, Revue de chirurgie orthopedique et reparatrice de l'appareil moteur.

[5]  S. Kurtz,et al.  The noisy ceramic hip: is component malpositioning the cause? , 2008, The Journal of arthroplasty.

[6]  Laurent Sedel,et al.  Alumina-on-Alumina Total Hip Arthroplasty: A Minimum 18.5-Year Follow-up Study , 2002, The Journal of bone and joint surgery. American volume.

[7]  John Charnley,et al.  Low Friction Arthroplasty of the Hip , 1979 .

[8]  B. W. Schreurs,et al.  High Incidence of Squeaking in THAs with Alumina Ceramic-on-ceramic Bearings , 2008, Clinical orthopaedics and related research.

[9]  Christopher A. Jarrett,et al.  The Squeaking Hip: An Underreported Phenomenon of Ceramic-On-Ceramic Total Hip Arthroplasty , 2007 .

[10]  Abd Rahim AbuBakar,et al.  Complex eigenvalue analysis and dynamic transient analysis in predicting disc brake squeal , 2006 .

[11]  John Fisher,et al.  Severe wear and fracture of zirconia heads against alumina inserts in hip simulator studies with microseparation. , 2003, The Journal of arthroplasty.

[12]  D. Dennis,et al.  The squeaking hip: a cause for concern-disagrees. , 2007, Orthopedics.

[13]  D A Dennis,et al.  "In vivo" determination of hip joint separation and the forces generated due to impact loading conditions. , 2001, Journal of biomechanics.

[14]  Michael M Morlock,et al.  Squeak in hip endoprosthesis systems: An experimental study and a numerical technique to analyze design variants. , 2010, Medical engineering & physics.

[15]  T M Ecker,et al.  Squeaking in total hip replacement: no cause for concern. , 2008, Orthopedics.

[16]  Gregory D. Liles Analysis of Disc Brake Squeal Using Finite Element Methods , 1989 .

[17]  W. Walter,et al.  Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation. , 2007, The Journal of arthroplasty.

[18]  M. Morlock,et al.  Friction‐Induced Vibration of Artificial Hip Joints , 2009 .

[19]  Gui-Rong Liu,et al.  Analysis of disc brake squeal using the complex eigenvalue method , 2007 .

[20]  N Shiba,et al.  Biomechanical study of the resurfacing hip arthroplasty: finite element analysis of the femoral component. , 2000, The Journal of arthroplasty.

[21]  W. Capello,et al.  Ceramic-on-ceramic total hip arthroplasty: update. , 2008, The Journal of arthroplasty.

[22]  A. Akay Acoustics of friction. , 2002, The Journal of the Acoustical Society of America.

[23]  G. Bergmann,et al.  Hip contact forces and gait patterns from routine activities. , 2001, Journal of biomechanics.

[24]  A. Amis,et al.  Finite element modelling of primary hip stem stability: the effect of interference fit. , 2008, Journal of biomechanics.

[25]  Richard D Komistek,et al.  A non-invasive acoustic and vibration analysis technique for evaluation of hip joint conditions. , 2010, Journal of biomechanics.

[26]  M. Tannast,et al.  Two- to 9-Year Clinical Results of Alumina Ceramic-on-Ceramic THA , 2006, Clinical orthopaedics and related research.

[27]  J Fisher,et al.  Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. , 2000, The Journal of arthroplasty.

[28]  J Fisher,et al.  Alumina-alumina artificial hip joints. Part II: characterisation of the wear debris from in vitro hip joint simulations. , 2002, Biomaterials.

[29]  Tarun Goswami,et al.  Finite element analysis of hip stem designs , 2008 .

[30]  Ryan L Bliss,et al.  Influence of prosthetic design on squeaking after ceramic-on-ceramic total hip arthroplasty. , 2010, The Journal of arthroplasty.

[31]  Wang Cheng-tao Tribology problems in natural and artificial joint. , 2009 .