Ambulation After Incomplete Spinal Cord Injury With EMG-Triggered Functional Electrical Stimulation

Individuals with incomplete spinal cord injury (iSCI) retain some control of the partially paralyzed muscles, necessitating careful integration of functional electrical stimulation (FES) with intact motor function. In this communication, the volitional surface electromyogram (sEMG) from partially paralyzed muscle was used to detect the intent to step in an iSCI volunteer. The classifier was able to trigger the FES-assisted swing phase with a false positive rate less than 1% and true positive rate of 82% for left foot-off (FO) and 83% for right FO over 110 steps taken during three testing sessions spread over a week.

[1]  H. Hermens,et al.  European recommendations for surface electromyography: Results of the SENIAM Project , 1999 .

[2]  Heng Tao Shen,et al.  Principal Component Analysis , 2009, Encyclopedia of Biometrics.

[3]  M.R. Popovic,et al.  A reliable gait phase detection system , 2001, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[4]  Kim D Nielsen,et al.  Biopotentials as command and feedback signals in functional electrical stimulation systems. , 2003, Medical engineering & physics.

[5]  M. Popovic,et al.  Functional electrical therapy: retraining grasping in spinal cord injury , 2006, Spinal Cord.

[6]  D. Graupe,et al.  Control of neuromuscular stimulation for ambulation by complete paraplegics via artificial neural networks , 2001, Neurological research.

[7]  R J Triolo,et al.  Muscle selection and walking performance of multichannel FES systems for ambulation in paraplegia. , 1997, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[8]  Patrick E. Crago,et al.  Stimulus artifact removal in EMG from muscles adjacent to stimulated muscles , 1996, Journal of Neuroscience Methods.

[9]  H. Hermens,et al.  SENIAM 8: European recommendations for surface electromyography , 1999 .

[10]  E. Marsolais,et al.  Implanted functional electrical stimulation system for mobility in paraplegia: a follow-up case report. , 1999, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[11]  G. Lyons,et al.  The use of accelerometry to detect heel contact events for use as a sensor in FES assisted walking. , 2003, Medical engineering & physics.

[12]  Y. Hurmuzlu,et al.  On the measurement of dynamic stability of human locomotion. , 1994, Journal of biomechanical engineering.