Principles of Cord Activation During Spinal Cord Stimulation

This study aims to review some of the basic principles of extracellular electrical stimulation used in spinal cord stimulation therapy for intractable pain.

[1]  W. D. Thompson,et al.  Excitation of pyramidal tract cells by intracortical microstimulation: effective extent of stimulating current. , 1968, Journal of neurophysiology.

[2]  S L BeMent,et al.  A quantitative study of electrical stimulation of central myelinated fibers. , 1969, Experimental neurology.

[3]  J. B. Ranck,et al.  Which elements are excited in electrical stimulation of mammalian central nervous system: A review , 1975, Brain Research.

[4]  D. Mcneal Analysis of a Model for Excitation of Myelinated Nerve , 1976, IEEE Transactions on Biomedical Engineering.

[5]  J. Mortimer,et al.  The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation , 1983, IEEE Transactions on Biomedical Engineering.

[6]  D. C. West,et al.  Strength‐duration characteristics of myelinated and non‐myelinated bulbospinal axons in the cat spinal cord. , 1983, The Journal of physiology.

[7]  F. Rattay Analysis of Models for External Stimulation of Axons , 1986, IEEE Transactions on Biomedical Engineering.

[8]  G. Barolat,et al.  Multifactorial analysis of epidural spinal cord stimulation. , 1991, Stereotactic and functional neurosurgery.

[9]  Steven Piantadosi,et al.  Spinal cord stimulation for chronic, intractable pain: Superiority of “multi-channel” devices , 1991, Pain.

[10]  D. Durand,et al.  Modeling the effects of electric fields on nerve fibers: Determination of excitation thresholds , 1992, IEEE Transactions on Biomedical Engineering.

[11]  J. Holsheimer,et al.  Recruitment of dorsal column fibers in spinal cord stimulation: influence of collateral branching , 1992, IEEE Transactions on Biomedical Engineering.

[12]  J. Holsheimer,et al.  Excitation of dorsal root fibers in spinal cord stimulation: a theoretical study , 1993, IEEE Transactions on Biomedical Engineering.

[13]  Jiping He,et al.  Paresthesia thresholds in spinal cord stimulation: a comparison of theoretical results with clinical data , 1993 .

[14]  Jiping He,et al.  Perception threshold and electrode position for spinal cord stimulation , 1994, Pain.

[15]  J Holsheimer,et al.  MR assessment of the normal position of the spinal cord in the spinal canal. , 1994, AJNR. American journal of neuroradiology.

[16]  Warren M. Grill,et al.  Stimulus waveforms for selective neural stimulation , 1995 .

[17]  J Holsheimer,et al.  Significance of the spinal cord position in spinal cord stimulation. , 1995, Acta neurochirurgica. Supplement.

[18]  E. J. Tehovnik Electrical stimulation of neural tissue to evoke behavioral responses , 1996, Journal of Neuroscience Methods.

[19]  W. Grill,et al.  The effect of stimulus pulse duration on selectivity of neural stimulation , 1996, IEEE Transactions on Biomedical Engineering.

[20]  G. Barolat Epidural Spinal Cord Stimulation: Anatomical and Electrical Properties of the Intraspinal Structures Relevant to Spinal Cord Stimulation and Clinical Correlations , 1998, Neuromodulation : journal of the International Neuromodulation Society.

[21]  R. North,et al.  Postural Changes in Spinal Cord Stimulation Perceptual Thresholds , 1998, Neuromodulation : journal of the International Neuromodulation Society.

[22]  G. Barolat,et al.  Spinal Geometry and Paresthesia Coverage in Spinal Cord Stimulation , 1998, Neuromodulation : journal of the International Neuromodulation Society.

[23]  Jan Holsheimer,et al.  Computer modelling of spinal cord stimulation and its contribution to therapeutic efficacy , 1998, Spinal Cord.

[24]  K. Aló,et al.  Effects of Posture on Stimulation Parameters in Spinal Cord Stimulation , 1998, Neuromodulation : journal of the International Neuromodulation Society.

[25]  W A Wesselink,et al.  Clinical evaluation of paresthesia steering with a new system for spinal cord stimulation. , 1998, Neurosurgery.

[26]  W A Wesselink,et al.  Analysis of current density and related parameters in spinal cord stimulation. , 1998, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[27]  C. McIntyre,et al.  Excitation of central nervous system neurons by nonuniform electric fields. , 1999, Biophysical journal.

[28]  Robert Plonsey,et al.  Electrical Stimulation of Excitable Tissue , 2000 .

[29]  J. Sieracki,et al.  Spinal Cord Stimulation Electrode Design: Prospective, Randomized, Controlled Trial Comparing Percutaneous and Laminectomy Electrodes—Part I: Technical Outcomes , 2002, Neurosurgery.

[30]  A. Sharan,et al.  Evolving Patterns of Spinal Cord Stimulation in Patients Implanted for Intractable Low Back and Leg Pain , 2002, Neuromodulation : journal of the International Neuromodulation Society.

[31]  J. Holsheimer Principles of neurostimulation , 2003 .

[32]  W. Grill,et al.  Sensitivity of temporal excitation properties to the neuronal element activated by extracellular stimulation , 2004, Journal of Neuroscience Methods.

[33]  Daniel R. Merrill,et al.  Electrical stimulation of excitable tissue: design of efficacious and safe protocols , 2005, Journal of Neuroscience Methods.

[34]  Ljubomir Manola,et al.  Technical Performance of Percutaneous Leads for Spinal Cord Stimulation: A Modeling Study , 2005, Neuromodulation : journal of the International Neuromodulation Society.

[35]  J. Holsheimer,et al.  Effects of electrode geometry and combination on nerve fibre selectivity in spinal cord stimulation , 1995, Medical and Biological Engineering and Computing.

[36]  J. Struijk,et al.  Transverse tripolar spinal cord stimulation: Theoretical performance of a dual channel system , 1996, Medical and Biological Engineering and Computing.

[37]  Electronic aspects of spinal-cord stimulation in multiple sclerosis , 2006, Medical and Biological Engineering and Computing.

[38]  J. Holsheimer,et al.  Factors Affecting Impedance of Percutaneous Leads in Spinal Cord Stimulation , 2006, Neuromodulation : journal of the International Neuromodulation Society.

[39]  J. Holsheimer,et al.  Optimum electrode geometry for spinal cord stimulation: The narrow bipole and tripole , 1997, Medical and Biological Engineering and Computing.

[40]  Jan Geelen,et al.  Modelling motor cortex stimulation for chronic pain control: Electrical potential field, activating functions and responses of simple nerve fibre models , 2005, Medical and Biological Engineering and Computing.

[41]  C. McIntyre,et al.  Sources and effects of electrode impedance during deep brain stimulation , 2006, Clinical Neurophysiology.

[42]  J. Holsheimer,et al.  A model of the electrical behaviour of myelinated sensory nerve fibres based on human data , 1999, Medical & Biological Engineering & Computing.

[43]  Leslie A. Geddes,et al.  Comparison of rectangular and exponential current pulses for evoking sensation , 2006, Annals of Biomedical Engineering.

[44]  D. Abejón,et al.  Is impedance a parameter to be taken into account in spinal cord stimulation? , 2007, Pain physician.

[45]  Douglas Montgomery,et al.  Computer modelling , 2009, Qual. Reliab. Eng. Int..

[46]  T. Yearwood,et al.  Pulse width programming in spinal cord stimulation: a clinical study. , 2010, Pain physician.

[47]  D. Abejón,et al.  Electric Parameters Optimization in Spinal Cord Stimulation. Study in Conventional Nonrechargeable Systems , 2010, Neuromodulation : journal of the International Neuromodulation Society.

[48]  J. Holsheimer,et al.  The Effect of Pulse Width and Contact Configuration on Paresthesia Coverage in Spinal Cord Stimulation , 2011, Neurosurgery.

[49]  C. M. Schade,et al.  Automatic adaptation of neurostimulation therapy in response to changes in patient position: results of the Posture Responsive Spinal Cord Stimulation (PRS) Research Study. , 2011, Pain physician.

[50]  Dongchul Lee,et al.  Predicted effects of pulse width programming in spinal cord stimulation: a mathematical modeling study , 2011, Medical & Biological Engineering & Computing.