Biomechanical evaluation of the Pulvertaft versus the ‘wrap around’ tendon suture technique

The purpose of this study was to compare the biomechanical properties of a novel wrap around tendon repair method with those of the standard Pulvertaft technique used for tendon reconstructions. Seventy-two porcine extensor tendons were used to create 36 reconstructions in six sets of six repairs, each using one of the two surgical techniques with differing lengths of the reconstructions. All the reconstructions were tested in vitro by cyclic tensile loading, resulting in the time-zero strength. When only the size of the repair and the strength were compared, and length of the reconstruction was not taken in consideration, the ‘wrap around’ reconstructions were of similar strength but less bulky than the Pulvertaft repairs. In conclusion, the ‘wrap around’ technique gives a thinner reconstruction which is as strong as, or stronger than the Pulvertaft technique, depending on the amount of weaves.

[1]  Stephen H. M. Brown,et al.  Mechanical strength of the side-to-side versus Pulvertaft weave tendon repair. , 2010, The Journal of hand surgery.

[2]  S. Bidic,et al.  Biomechanical Comparison of Lasso, Pulvertaft Weave, and Side-by-Side Tendon Repairs , 2009, Plastic and reconstructive surgery.

[3]  S. Hovius,et al.  Influence of Core Suture Geometry on Tendon Deformation and Gap Formation in Porcine Flexor Tendons , 2009, The Journal of hand surgery, European volume.

[4]  R. Xie,et al.  Digital Oedema, Adhesion Formation and Resistance to Digital Motion after Primary Flexor Tendon Repair , 2008, The Journal of hand surgery, European volume.

[5]  L. de Smet,et al.  In vitro biomechanical study to compare the double-loop technique with the Pulvertaft weave for tendon anastomosis , 2008, Scandinavian journal of plastic and reconstructive surgery and hand surgery.

[6]  S. Dodd,et al.  An In Vitro Biomechanical Study Comparing the Spiral Linking Technique Against the Pulvertaft Weave for Tendon Repair , 2007, The Journal of hand surgery, European volume.

[7]  G. Baek,et al.  A loop-tendon suture for tendon transfer or graft surgery. , 2007, The Journal of hand surgery.

[8]  S. Berner Tensile Strength of a New Suture for Fixation of Tendon Grafts When Using a Weave Technique , 2007 .

[9]  K. An,et al.  Total and intrasynovial work of flexion of human cadaver flexor digitorum profundus tendons after modified Kessler and MGH repair techniques. , 2005, The Journal of hand surgery.

[10]  Karen M. Pettengill The evolution of early mobilization of the repaired flexor tendon. , 2005, Journal of hand therapy : official journal of the American Society of Hand Therapists.

[11]  K. An,et al.  The effect of suture technique on adhesion formation after flexor tendon repair for partial lacerations in a canine model. , 2001, The Journal of trauma.

[12]  J. W. Strickland Development of flexor tendon surgery: twenty-five years of progress. , 2000, The Journal of hand surgery.

[13]  M. Nowak,et al.  Tensile Strength of the End-Weave Flexor Tendon Repair , 1994, Journal of hand surgery.

[14]  M. Merrilees,et al.  Ultrastructural study of tension and pressure zones in a rabbit flexor tendon. , 1980, The American journal of anatomy.

[15]  R. Pulvertaft Suture Materials and Tendon Junctures , 1965 .

[16]  R. Pulvertaft SUTURE MATERIALS AND TENDON JUNCTURES. , 1965, American journal of surgery.