Research on the characteristics of upward leader emerging from the transmission lines influenced by operation voltage

The problem whether the DC operation voltage can influence the characteristics of upward leader emerging from transmission lines is still in question since experiments and observation data is insufficient. It is necessary to study the relationship between the characteristics of the upward leaders and operation voltage. This paper presents some simulated experimental results of a combined plane-rod (PR) electrode to conductor air gap of 7 meter length. A current measuring instrument with frequency response of from DC to 6.5MHz was developed and used to measure the leader current. Besides, high speed CCD camera was used to observe the optical phenomenon of the whole process. The 200/2000μs impulse voltage up to 4MV and positive DC voltage up to 800kV was applied to the electrode and conductor respectively. The higher charge per unit in the leader channel and earlier inception time has been found along the higher DC voltage. These results have been compared with those in the gap that only impulse voltage was applied. Finally, the influence of positive DC voltage on the characteristics of upward leaders was discussed.

[1]  E. Garbagnati,et al.  Lightning stroke simulation by means of the leader progression model. I. Description of the model and evaluation of exposure of free-standing structures , 1990 .

[2]  Yu Zhanqing,et al.  Research on the upward leader emerging from transmission line by simulation experiments , 2011, 2011 7th Asia-Pacific International Conference on Lightning.

[3]  M. Sadeghzadeh-Araghi,et al.  A study of initial negative discharge growth using video camera and frame store , 1988, 1988. Annual Report., Conference on Electrical Insulation and Dielectric Phenomena.

[4]  Mazen Abdel-Salam,et al.  Simulation of energized Franklin rods for lightning protection , 1997 .

[5]  Tomomi Narita,et al.  Characteristics of Direct Lightning Strokes to Phase Conductors on UHV Designed Transmission Lines , 2002 .

[6]  Pantelis N. Mikropoulos,et al.  Effects of negative direct voltage pre-stressing on the breakdown of conductor-rod gaps under positive impulse voltages , 1998 .

[7]  Zhao Jie,et al.  Influence of Conductor Voltage on the Striking Distance of Electrogeometric Model , 2007 .

[8]  Yasuo Watanabe Influence of Preexisting DC Voltage on Switching Surge Flashover Characteristics , 1968 .

[9]  Gordon W. Brown Lightning Performance -- I Shielding Failures Simplified , 1978, IEEE Transactions on Power Apparatus and Systems.

[10]  R. Morrow,et al.  RAPID COMMUNICATION: The discharge current induced by the motion of charged particles in time-dependent electric fields; Sato's equation extended , 1999 .