MEMS Thermal Sensors to Detect Changes in Heat Transfer in the Pre-Atherosclerotic Regions of Fat-Fed New Zealand White Rabbits

Real-time detection of pre-atherosclerotic regions remains an unmet clinical challenge. We previously demonstrated the application of micro-electro-mechanical systems (MEMS) to detect changes in convective heat transfer in terms of sensor output voltages in the zone of flow reversal in an in vitro stenotic model. We hereby demonstrated changes in sensor output voltages in the pre-atherosclerotic regions in the New Zealand White rabbits fed on hypercholesterolemic diet (HD). After 8 weeks, we observed that mean output voltages (Vave) were similar in the distal aortic arch, thoracic, and abdominal aortas in the normal standard diet (ND) group, consistent with an absence of atherosclerosis. In HD group, Vave increased in the distal aortic arch (HD: Vave = 1.05 ± 0.04 V; ND: Vave = 0.12 ± 0.01 V, n = 3, p < 0.05) and in the thoracic aortas (HD: Vave = 0.72 ± 0.06 V; ND: Vave = 0.13 ± 0.024 V, n = 3, p < 0.05), consistent with the histological presence of pre-atherosclerosis. Despite HD diet, Vave magnitudes were similar to ND group in the abdominal aortas (HD: Vave = 0.14 ± 0.003 V; ND: Vave = 0.14 ± 0.004 V, n = 3), corroborating histological absence of pre-atherosclerosis. Hence, MEMS thermal sensors provide a new approach to detect changes in convective heat transfer in the pre-atherosclerotic regions.

[1]  Tzung K Hsiai,et al.  Real-time assessment of flow reversal in an eccentric arterial stenotic model. , 2010, Journal of biomechanics.

[2]  Tiantian C. Lin,et al.  Spatial Variations in Shear Stress in a 3-D Bifurcation Model at Low Reynolds Numbers , 2005, Annals of Biomedical Engineering.

[3]  Tzung K Hsiai,et al.  Pulsatile Versus Oscillatory Shear Stress Regulates NADPH Oxidase Subunit Expression: Implication for Native LDL Oxidation , 2003, Circulation research.

[4]  Clark K. Colton,et al.  Microcinematographic studies of flow patterns in the excised rabbit aorta and its major branches. , 1997, Biorheology.

[5]  F. Van de Werf,et al.  Circulating Oxidized LDL Is a Useful Marker for Identifying Patients With Coronary Artery Disease , 2001, Arteriosclerosis, thrombosis, and vascular biology.

[6]  K B Chandran,et al.  Numerical study on the effect of secondary flow in the human aorta on local shear stresses in abdominal aortic branches. , 2000, Journal of biomechanics.

[7]  Guang-Zhong Yang,et al.  Helical and Retrograde Secondary Flow Patterns in the Aortic Arch Studied by Three‐Directional Magnetic Resonance Velocity Mapping , 1993, Circulation.

[8]  M. Gimbrone,et al.  Identification of vascular endothelial genes differentially responsive to fluid mechanical stimuli: cyclooxygenase-2, manganese superoxide dismutase, and endothelial cell nitric oxide synthase are selectively up-regulated by steady laminar shear stress. , 1996, Proceedings of the National Academy of Sciences of the United States of America.

[9]  B. Berk Atheroprotective Signaling Mechanisms Activated by Steady Laminar Flow in Endothelial Cells , 2008, Circulation.

[10]  Michail I. Papafaklis,et al.  Natural History of Experimental Coronary Atherosclerosis and Vascular Remodeling in Relation to Endothelial Shear Stress: A Serial, In Vivo Intravascular Ultrasound Study , 2010, Circulation.

[11]  C F Dewey,et al.  Turbulent fluid shear stress induces vascular endothelial cell turnover in vitro. , 1986, Proceedings of the National Academy of Sciences of the United States of America.

[12]  Hongyu Yu,et al.  Optimization of intravascular shear stress assessment in vivo. , 2009, Journal of biomechanics.

[13]  D. Ku BLOOD FLOW IN ARTERIES , 1997 .

[14]  L. N. Persen,et al.  On the measurement of wall shear stress , 1986 .

[15]  N. Kume [Oxidized LDL]. , 2001, Nihon rinsho. Japanese journal of clinical medicine.

[16]  Y. Tai,et al.  Surface micromachined thermal shear stress sensor , 1994 .

[17]  Vasilis Ntziachristos,et al.  Real-Time Catheter Molecular Sensing of Inflammation in Proteolytically Active Atherosclerosis , 2008, Circulation.

[18]  E. Edelman,et al.  Prediction of the Localization of High-Risk Coronary Atherosclerotic Plaques on the Basis of Low Endothelial Shear Stress: An Intravascular Ultrasound and Histopathology Natural History Study , 2008, Circulation.

[19]  Takafumi Hiro,et al.  Longitudinal structural determinants of atherosclerotic plaque vulnerability: a computational analysis of stress distribution using vessel models and three-dimensional intravascular ultrasound imaging. , 2005, Journal of the American College of Cardiology.

[20]  Hongyu Yu,et al.  Shear stress influences spatial variations in vascular Mn-SOD expression: implication for LDL nitration. , 2008, American journal of physiology. Cell physiology.

[21]  Hongyu Yu,et al.  Flexible Polymer Sensors for In Vivo Intravascular Shear Stress Analysis , 2008, Journal of Microelectromechanical Systems.

[22]  Tzung K. Hsiai,et al.  Real-Time Intravascular Shear Stress in the Rabbit Abdominal Aorta , 2009, IEEE Transactions on Biomedical Engineering.

[23]  M. Webster,et al.  Wall stress distribution on three-dimensionally reconstructed models of human abdominal aortic aneurysm. , 2000, Journal of vascular surgery.

[24]  R M Nerem,et al.  The study of the influence of flow on vascular endothelial biology. , 1998, The American journal of the medical sciences.

[25]  Joseph H. Haritonidis,et al.  The Measurement of Wall Shear Stress , 1989 .

[26]  T. Chandratilleke,et al.  Numerical prediction of secondary flow and convective heat transfer in externally heated curved rectangular ducts , 2003 .

[27]  M. Runge,et al.  Oxidative Stress and Vascular Disease , 2004, Arteriosclerosis, thrombosis, and vascular biology.

[28]  S. Dymarkowski,et al.  Dietary cholesterol withdrawal reduces vascular inflammation and induces coronary plaque stabilization in miniature pigs. , 2002, Cardiovascular research.

[29]  A. Wahle,et al.  Effect of Endothelial Shear Stress on the Progression of Coronary Artery Disease, Vascular Remodeling, and In-Stent Restenosis in Humans: In Vivo 6-Month Follow-Up Study , 2003, Circulation.

[30]  S. Berger,et al.  Flows in Stenotic Vessels , 2000 .

[31]  G. Truskey,et al.  Association between secondary flow in models of the aorto-celiac junction and subendothelial macrophages in the normal rabbit. , 1998, Atherosclerosis.

[32]  Chih-Ming Ho,et al.  Endothelial Cell Dynamics under Pulsating Flows: Significance of High Versus Low Shear Stress Slew Rates (∂τ/∂τ) , 2002, Annals of Biomedical Engineering.

[33]  S. Hazen,et al.  Hemodynamics influences vascular peroxynitrite formation: Implication for low-density lipoprotein apo-B-100 nitration. , 2007, Free radical biology & medicine.

[34]  T W Taylor,et al.  Three-dimensional simulation of blood flow in an abdominal aortic aneurysm--steady and unsteady flow cases. , 1994, Journal of biomechanical engineering.

[35]  C. Lien,et al.  Micro-Electrocardiograms to Study Post-Ventricular Amputation of Zebrafish Heart , 2009, Annals of Biomedical Engineering.

[36]  F. Werf,et al.  Oxidized LDL and malondialdehyde-modified LDL in patients with acute coronary syndromes and stable coronary artery disease. , 1998, Circulation.