Real-time, near-infrared, fluorescence-guided identification of the ureters using methylene blue.

BACKGROUND The aim of this study was to determine whether the invisible near-infrared (NIR) fluorescence properties of methylene blue (MB), a dye already approved by the U.S. Food and Drug Administration for other indications, could be exploited for real-time, intra-operative identification of the ureters. METHODS The optical properties of MB were quantified in vitro. Open surgery and laparoscopic NIR fluorescence imaging systems were employed. Yorkshire pigs were injected intravenously with 0.1-mg/kg MB (n = 8), 10-mg furosemide followed by 0.1-mg/kg MB (n = 6), or 0.5-mg/kg MB (n = 6). The contrast-to-background ratio (CBR) of the kidney and ureters, and the MB concentration in the urine, were quantified. RESULTS Peak MB absorbance, emission, and intensity in urine occurred at 668 nm, 688 nm, and 20 mumol/L, respectively. After intravenous injection, doses as low as 0.1-mg/kg MB provided prolonged imaging of the ureters, and a dose of 0.5 mg/kg provided statistically significant improvement of CBR. The preinjection of furosemide increased urine volume but did not improve CBR. Laparoscopic identification of the ureter using MB NIR fluorescence was demonstrated. CONCLUSION Ureteral imaging using MB NIR fluorescence provides sensitive, real-time, intra-operative identification of the ureters during open and laparoscopic surgeries.

[1]  Hak Soo Choi,et al.  Real-time intraoperative ureteral guidance using invisible near-infrared fluorescence. , 2007, The Journal of urology.

[2]  J. Wagner,et al.  Pharmacokinetics of highly ionized drugs. I. Methylene blue--whole blood, urine, and tissue assays. , 1972, Journal of pharmaceutical sciences.

[3]  Sylvain Gioux,et al.  High-Power, Computer-Controlled, Light-Emitting Diode–Based Light Sources for Fluorescence Imaging and Image-Guided Surgery , 2009, Molecular imaging.

[4]  B. Mokhlesi,et al.  Adult toxicology in critical care: Part II: specific poisonings. , 2003, Chest.

[5]  J. Jones,et al.  Management of ureteral injuries associated with vaginal surgery for pelvic organ prolapse , 2006, International Urogynecology Journal.

[6]  K. H. Drexhage,et al.  Fluorescence quantum yield of oxazine and carbazine laser dyes , 1981 .

[7]  L. Ngo,et al.  The FLARE™ Intraoperative Near-Infrared Fluorescence Imaging System: A First-in-Human Clinical Trial in Breast Cancer Sentinel Lymph Node Mapping , 2009, Annals of Surgical Oncology.

[8]  E. Everts,et al.  Appropriate timing and velocity of infusion for the selective staining of parathyroid glands by intravenous methylene blue. , 1998, American journal of surgery.

[9]  A. Majithia,et al.  Methylene blue toxicity following infusion to localize parathyroid adenoma , 2005, The Journal of Laryngology & Otology.

[10]  J. Wagner,et al.  Pharmacokinetics of highly ionized drugs. II. Methylene blue--absorption, metabolism, and excretion in man and dog after oral administration. , 1972, Journal of pharmaceutical sciences.

[11]  M. Bawendi,et al.  Sentinel lymph node mapping with type-II quantum dots. , 2007, Methods in molecular biology.

[12]  J P Spirnak,et al.  Iatrogenic ureteral injuries: a 20-year experience in treating 165 injuries. , 1996, The Journal of urology.

[13]  B. Lauterburg,et al.  Pharmacokinetics and organ distribution of intravenous and oral methylene blue , 2000, European Journal of Clinical Pharmacology.

[14]  D. Gal,et al.  Prophylactic ureteral catheterization in gynecologic surgery. , 1999, Urology.

[15]  D. Chadwick,et al.  Prolonged postoperative altered mental status after methylene blue infusion during parathyroidectomy: a case report and review of the literature. , 2007, Annals of the Royal College of Surgeons of England.

[16]  Fred W Lindsay,et al.  Prolonged Postoperative Disorientation After Methylene Blue Infusion During Parathyroidectomy , 2004, Anesthesia and Analgesia.

[17]  K. Taber,et al.  Cost‐Effectiveness of Universal Cystoscopy to Identify Ureteral Injury at Hysterectomy , 2001, Obstetrics and gynecology.

[18]  J. Frangioni In vivo near-infrared fluorescence imaging. , 2003, Current opinion in chemical biology.

[19]  D. Meirow,et al.  Evaluation and treatment of iatrogenic ureteral injuries during obstetric and gynecologic operations for nonmalignant conditions. , 1994, Journal of the American College of Surgeons.

[20]  K. Nelson,et al.  Intraoperative gamma probe localization of the ureters: a novel concept. , 2007, Journal of the American College of Surgeons.

[21]  P. A. Bombardt,et al.  An on-line, column-switching high-performance liquid chromatographic procedure for the removal of probenecid from human plasma, serum, or urine in the quantitative determination of cefmetazole or cefoxitin. , 1989, Journal of pharmaceutical and biomedical analysis.

[22]  D. Assimos,et al.  Changing incidence and etiology of iatrogenic ureteral injuries. , 1994, The Journal of urology.