Respiratory Motion Correction in Oncologic PET Using T1-Weighted MR Imaging on a Simultaneous Whole-Body PET/MR System

Hybrid PET/MR combines the exceptional molecular sensitivity of PET with the high resolution and versatility of MR imaging. Simultaneous data acquisition additionally promises the use of MR to enhance the quality of PET images, for example, by respiratory motion correction. This advantage is especially relevant in thoracic and abdominal areas to improve the visibility of small lesions with low radiotracer uptake and to enhance uptake quantification. In this work, the applicability and performance of an MR-based method of respiratory motion correction for PET tumor imaging was evaluated in phantom and patient studies. Methods: PET list-mode data from a motion phantom with 22Na point sources and 5 patients with tumor manifestations in the thorax and upper abdomen were acquired on a simultaneous hybrid PET/MR system. During the first 3 min of a 5-min PET scan, the respiration-induced tissue deformation in the PET field of view was recorded using a sagittal 2-dimensional multislice gradient echo MR sequence. MR navigator data to measure the location of the diaphragm were acquired throughout the PET scan. Respiration-gated PET data were coregistered using the MR-derived motion fields to obtain a single motion-corrected PET dataset. The effect of motion correction on tumor visibility, delineation, and radiotracer uptake quantification was analyzed with respect to uncorrected and gated images. Results: Image quality in terms of lesion delineation and uptake quantification was significantly improved compared with uncorrected images for both phantom and patient data. In patients, in head–feet line profiles of 14 manifestations, the slope became steeper by 66.7% (P = 0.001) and full width at half maximum was reduced by 20.6% (P = 0.001). The mean increase in maximum standardized uptake value, lesion-to-background ratio (contrast), and signal-to-noise ratio was 28.1% (P = 0.001), 24.7% (P = 0.001), and 27.3% (P = 0.003), respectively. Lesion volume was reduced by an average of 26.5% (P = 0.002). As opposed to the gated images, no increase in background noise was observed. However, motion correction performed worse than gating in terms of contrast (−11.3%, P = 0.002), maximum standardized uptake value (−10.7%, P = 0.003), and slope steepness (−19.3%, P = 0.001). Conclusion: The proposed method for MR-based respiratory motion correction of PET data proved feasible and effective. The short examination time and convenience (no additional equipment required) of the method allow for easy integration into clinical routine imaging. Performance compared with gating procedures can be further improved using list-mode–based motion correction.

[1]  Bernd J. Pichler,et al.  Assessment of rodent brain activity using combined [15O]H2O-PET and BOLD-fMRI , 2014, NeuroImage.

[2]  F. Schick,et al.  Achillodynia – Radiological Imaging of Acute and Chronic Overuse Injuries of the Achilles Tendon , 2013, Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren.

[3]  F. Schick,et al.  Magnetic resonance imaging of solid dental restoration materials using 3D UTE sequences: visualization and relaxometry of various compounds , 2013, Magnetic Resonance Materials in Physics, Biology and Medicine.

[4]  Comparison between High-Resolution CT and MRI Using a Very Short Echo Time in Patients with Cystic Fibrosis with Extra Focus on Mosaic Attenuation , 2012, Respiration.

[5]  Ciprian Catana,et al.  MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI , 2012, The Journal of Nuclear Medicine.

[6]  T Schaeffter,et al.  Thoracic respiratory motion estimation from MRI using a statistical model and a 2-D image navigator , 2012, Medical Image Anal..

[7]  G. Delso,et al.  Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner , 2011, The Journal of Nuclear Medicine.

[8]  Z. Fayad,et al.  MRI-based motion correction of thoracic PET: initial comparison of acquisition protocols and correction strategies suitable for simultaneous PET/MRI systems , 2011, European Radiology.

[9]  Nikolaos Dikaios,et al.  Improved motion-compensated image reconstruction for PET using sensitivity correction per respiratory gate and an approximate tube-of-response backprojector. , 2011, Medical physics.

[10]  G El Fakhri,et al.  Nonrigid PET motion compensation in the lower abdomen using simultaneous tagged-MRI and PET imaging. , 2011, Medical physics.

[11]  Michael Brady,et al.  Motion Correction and Attenuation Correction for Respiratory Gated PET Images , 2011, IEEE Transactions on Medical Imaging.

[12]  Ciprian Catana,et al.  MRI-Assisted PET Motion Correction for Neurologic Studies in an Integrated MR-PET Scanner , 2011, The Journal of Nuclear Medicine.

[13]  Tobias Schaeffter,et al.  Simultaneous PET–MR acquisition and MR-derived motion fields for correction of non-rigid motion in PET , 2010, Annals of nuclear medicine.

[14]  Florian Büther,et al.  Optimal number of respiratory gates in positron emission tomography: a cardiac patient study. , 2009, Medical physics.

[15]  Nassir Navab,et al.  Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT Data , 2009, Journal of Nuclear Medicine.

[16]  Bernd J Pichler,et al.  Latest Advances in Molecular Imaging Instrumentation , 2008, Journal of Nuclear Medicine.

[17]  Ciprian Catana,et al.  Simultaneous PET-MRI: a new approach for functional and morphological imaging , 2008, Nature Medicine.

[18]  Xiaoyi Jiang,et al.  Respiratory Motion Correction in 3-D PET Data With Advanced Optical Flow Algorithms , 2008, IEEE Transactions on Medical Imaging.

[19]  Bong Soo Kim,et al.  Comparison of three free-breathing T2-weighted MRI sequences in the evaluation of focal liver lesions. , 2008, AJR. American journal of roentgenology.

[20]  A J Reader,et al.  List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations , 2007, Physics in medicine and biology.

[21]  Xiaoyi Jiang,et al.  Lung motion correction on respiratory gated 3-D PET/CT images , 2006, IEEE Transactions on Medical Imaging.

[22]  Jean-Claude Liehn,et al.  Respiratory motion artefact in the liver dome on FDG PET/CT: comparison of attenuation correction with CT and a caesium external source , 2005, European Journal of Nuclear Medicine and Molecular Imaging.

[23]  Guang-Zhong Yang,et al.  Predictive cardiac motion modeling and correction with partial least squares regression , 2004, IEEE Transactions on Medical Imaging.

[24]  A. Pevsner,et al.  The CT motion quantitation of lung lesions and its impact on PET-measured SUVs. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[25]  Yuji Nakamoto,et al.  PET/CT: artifacts caused by bowel motion , 2004, Nuclear medicine communications.

[26]  Yuji Nakamoto,et al.  Clinically significant inaccurate localization of lesions with PET/CT: frequency in 300 patients. , 2003, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[27]  David Atkinson,et al.  A study of the motion and deformation of the heart due to respiration , 2002, IEEE Transactions on Medical Imaging.

[28]  M. V. van Herk,et al.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[29]  C. Ling,et al.  Effect of respiratory gating on quantifying PET images of lung cancer. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[30]  M O Leach,et al.  Implications of respiratory motion for the quantification of 2D MR spectroscopic imaging data in the abdomen. , 2000, Physics in medicine and biology.

[31]  Jean-Philippe Thirion,et al.  Image matching as a diffusion process: an analogy with Maxwell's demons , 1998, Medical Image Anal..

[32]  I. Suramo,et al.  Cranio-Caudal Movements of the Liver, Pancreas and Kidneys in Respiration , 1984, Acta radiologica: diagnosis.

[33]  L. Cupples,et al.  Multiple testing of hypotheses in comparing two groups. , 1984, Annals of internal medicine.