Comparison between two different operation strategies for a heat-driven residential natural gas-fired CHP system: Heat dumping vs. load partialization

In this work, the results coming from the schedule optimization of a residential natural gas-fired CHP system operating according to a novel heat-driven operation strategy, based on the possibility to dump part of the thermal energy produced by the CHP system, are compared with the ones relative to the case in which the CHP system operates following a heat-driven strategy allowing load partialization. The effects of the variation of the size of the thermal energy storage system on the optimization results are also investigated. The simulation of the two different operation strategies has been realized using a numerical code written in Matlab environment, and a heuristic algorithm has been used for the economic optimization of the operation relative to both the implemented strategies. From the economic point of view, results show that the difference between the best CHP system configuration in the case with heat dumping and the one relative to the case with load partialization is minimal, with the latter presenting a slightly higher economic performance. Moreover, conditions in which heat dumping could yield higher economic performances than load partialization are also presented in this work. As concerns pollutants emissions, results show that the impact of load partialization on a local scale is much higher, with CO emissions that can be up to three times the ones relative to conventional systems for the separate generation of electricity and heat.

[1]  Fabio Polonara,et al.  State of the art of thermal storage for demand-side management , 2012 .

[2]  Gregor Verbic,et al.  Optimal sizing of biomass-fired Organic Rankine Cycle CHP system with heat storage , 2012 .

[3]  Janusz Skorek,et al.  Thermodynamic and economic analysis of heat storage application in co‐generation systems , 2005 .

[4]  Željko Bogdan,et al.  Improvement of the cogeneration plant economy by using heat accumulator , 2006 .

[5]  Shin'ya Obara,et al.  Economic and environmental based operation strategies of a hybrid photovoltaic–microgas turbine trigeneration system , 2014 .

[6]  Anders N. Andersen,et al.  Exploration of economical sizing of gas engine and thermal store for combined heat and power plants in the UK , 2008 .

[7]  Russell McKenna,et al.  Optimisation of the capacity and the dispatch of decentralised micro-CHP systems: A case study for the UK , 2015 .

[8]  Giovanni Ferrara,et al.  Influence of the heat storage size on the plant performance in a Smart User case study , 2013 .

[9]  Michael Baldea,et al.  Optimal operation of a residential district-level combined photovoltaic/natural gas power and cooling system , 2015 .

[10]  Carlo Roselli,et al.  Influence of climatic conditions and control logic on NOx and CO emissions of a micro-cogeneration unit serving an Italian residential building , 2014 .

[11]  C. Y. Zheng,et al.  Impacts of feed-in tariff policies on design and performance of CCHP system in different climate zones , 2016 .

[12]  Pedro J. Mago,et al.  Uncertainty based operating strategy selection in combined heat and power systems , 2016 .

[13]  Adam Hawkes,et al.  Cost-effective operating strategy for residential micro-combined heat and power , 2007 .

[14]  Nicola Bianco,et al.  Economic optimization of a residential micro-CHP system considering different operation strategies , 2016 .

[15]  Ibrahim Dincer,et al.  Thermodynamic modeling and multi-objective evolutionary-based optimization of a new multigeneration energy system , 2013 .

[16]  Michel Noussan,et al.  Biomass-fired CHP and heat storage system simulations in existing district heating systems , 2014 .

[17]  Pedro J. Mago,et al.  Effects of load-following operational methods on combined heat and power system efficiency , 2014 .

[18]  M. Lehtonen,et al.  Analyzing the optimal coordination of a residential micro-CHP system with a power sink , 2015 .

[19]  Lieve Helsen,et al.  The impact of thermal storage on the operational behaviour of residential CHP facilities and the overall CO2 emissions , 2007 .

[20]  Pierluigi Mancarella,et al.  Global and local emission impact assessment of distributed cogeneration systems with partial-load models , 2009 .

[21]  Mauro Reini,et al.  Optimization of a Distributed Cogeneration System with solar district heating , 2014 .

[22]  Andrea De Pascale,et al.  Guidelines for residential micro-CHP systems design , 2012 .

[23]  A. Fragaki,et al.  Conditions for aggregation of CHP plants in the UK electricity market and exploration of plant size , 2011 .

[24]  Naim Afgan,et al.  Multi-criteria evaluation for CHP system options , 2006 .

[25]  Christoph Koch,et al.  The contribution of heat storage to the profitable operation of combined heat and power plants in liberalized electricity markets , 2012 .

[26]  Anders N. Andersen,et al.  Feasibility of CHP-plants with thermal stores in the German spot market , 2009 .

[27]  Qunwei Wang,et al.  Measurement and decomposition of energy-saving and emissions reduction performance in Chinese cities , 2015 .

[28]  Risto Lahdelma,et al.  Optimization of combined heat and power production with heat storage based on sliding time window method , 2016 .

[29]  Graham Coates,et al.  Optimal online operation of residential μCHP systems using linear programming , 2012 .

[30]  Nan Li,et al.  Optimal design and operation strategy for integrated evaluation of CCHP (combined cooling heating and power) system , 2016 .

[31]  Guzmán Díaz,et al.  Valuation under uncertain energy prices and load demands of micro-CHP plants supplemented by optimally switched thermal energy storage , 2016 .

[32]  Nicola Bianco,et al.  Influence of heat dumping on the operation of residential micro-CHP systems , 2015 .

[33]  Francesco Melino,et al.  Influence of the thermal energy storage on the profitability of micro-CHP systems for residential building applications , 2012 .

[34]  R. Kannan,et al.  Modelling the UK residential energy sector under long-term decarbonisation scenarios: Comparison between energy systems and sectoral modelling approaches , 2009 .

[35]  Pierluigi Mancarella,et al.  Emission characterization and evaluation of natural gas-fueled cogeneration microturbines and internal combustion engines , 2008 .

[36]  Giovanni Ciampi,et al.  Dynamic performance assessment of a building-integrated cogeneration system for an Italian residential application , 2013 .

[37]  Zhe Tian,et al.  The improvement of a simulation model for a distributed CCHP system and its influence on optimal operation cost and strategy , 2016 .

[38]  Xin Wang,et al.  Pre-feasibility of building cooling heating and power system with thermal energy storage considering energy supply–demand mismatch , 2016 .

[39]  Sara Rainieri,et al.  Modeling of a thermal energy storage system coupled with combined heat and power generation for the heating requirements of a University Campus , 2010 .

[40]  Mahmoud M. El-Halwagi,et al.  Optimal design of integrated CHP systems for housing complexes , 2015 .

[41]  Hongbo Ren,et al.  Economic and environmental evaluation of micro CHP systems with different operating modes for residential buildings in Japan , 2010 .