Column shortening due to creep and shrinkage of concrete should be predicted accurately, especially in high-rise buildings. One of the main mechanisms of creep and shrinkage is moisture diffusion. However, in steel-reinforced concrete columns, which are widely used in high-rise buildings, the wide-flange steel located inside the column hinders the diffusion of moisture. Consequently, the long-term shortening of the column is delayed due to the slower diffusion. A prediction method that takes into account the actual moisture diffusion inside the column is suggested in this paper. The effect of the wide-flange-steel geometry on the long-term deformation of concrete in a column is precisely demonstrated through parametric studies using this method. The results of the parametric study show that the ratio of the web length of the wide-flange steel to the square column size is one of the main parameters affecting the long-term deformation of concrete in steel-reinforced concrete columns.
[1]
Kenji Sakata,et al.
A study on moisture diffusion in drying and drying shrinkage of concrete
,
1983
.
[2]
Zdeněk P. Bažant,et al.
Mathematical modeling of creep and shrinkage of concrete
,
1988
.
[3]
Han-Soo Kim,et al.
Effect of differential moisture distribution on the shortening of steel-reinforced concrete columns
,
2008
.
[4]
Jin-Keun Kim,et al.
Prediction of differential drying shrinkage in concrete
,
1998
.
[5]
Z. Bažant,et al.
Drying creep of concrete: constitutive model and new experiments separating its mechanisms
,
1994
.