Origin of Infrared Light Modulation in Reflectance-Mode Photoplethysmography

We recently pointed out the important role of dermis deformation by pulsating arterial pressure in the formation of a photoplethysmographic signal at green light. The aim of this study was to explore the role of this novel finding in near-infrared (NIR) light. A light-emitting diode (LED)-based imaging photoplethysmography (IPPG) system was used to detect spatial distribution of blood pulsations under frame-to-frame switching green and NIR illumination in the palms of 34 healthy individuals. We observed a significant increase of light-intensity modulation at the heartbeat frequency for both illuminating wavelengths after a palm was contacted with a glass plate. Strong positive correlation between data measured at green and NIR light was found, suggesting that the same signal was read independently from the depth of penetration. Analysis of the data shows that an essential part of remitted NIR light is modulated in time as a result of elastic deformations of dermis caused by variable blood pressure in the arteries. Our observations suggest that in contrast with the classical model, photoplethysmographic waveform originates from the modulation of the density of capillaries caused by the variable pressure applied to the skin from large blood vessels. Particularly, beat-to-beat transmural pressure in arteries compresses/decompresses the dermis and deforms its connective-tissue components, thus affecting the distance between the capillaries, which results in the modulation of absorption and scattering coefficients of both green and NIR light. These findings are important for the correct interpretation of this widely used medical technique, which may have novel applications in diagnosis and treatment monitoring of aging and skin diseases.

[1]  Alexei A. Kamshilin,et al.  Variability of Microcirculation Detected by Blood Pulsation Imaging , 2013, PloS one.

[2]  Ashley J. Welch,et al.  Effects of compression on soft tissue optical properties , 1996 .

[3]  A. Kamshilin,et al.  Ambiguity of mapping the relative phase of blood pulsations. , 2014, Biomedical optics express.

[4]  P. Karjalainen,et al.  Asynchronicity of Facial Blood Perfusion in Migraine , 2013, PloS one.

[5]  J. Laidlaw,et al.  ANATOMY OF THE HUMAN BODY , 1967, The Ulster Medical Journal.

[6]  Toshiyo Tamura,et al.  The Advantages of Wearable Green Reflected Photoplethysmography , 2011, Journal of Medical Systems.

[7]  Daniel McDuff,et al.  Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam , 2011, IEEE Transactions on Biomedical Engineering.

[8]  F. Mastik,et al.  Contactless Multiple Wavelength Photoplethysmographic Imaging: A First Step Toward “SpO2 Camera” Technology , 2005, Annals of Biomedical Engineering.

[9]  Alexei A. Kamshilin,et al.  Photoplethysmographic imaging of high spatial resolution , 2011, Biomedical optics express.

[10]  M Intaglietta,et al.  Elastic Environment of the Capillary Bed , 1966, Circulation research.

[11]  T. Ward,et al.  Noncontact simultaneous dual wavelength photoplethysmography: a further step toward noncontact pulse oximetry. , 2007, The Review of scientific instruments.

[12]  Oleg V Mamontov,et al.  Influence of a skin status on the light interaction with dermis. , 2015, Biomedical optics express.

[13]  Shlomo Engelberg,et al.  Comparison of Systolic Blood Pressure Values Obtained by Photoplethysmography and by Korotkoff Sounds , 2013, Sensors.

[14]  A. N. Bashkatov,et al.  Optical properties of human skin, subcutaneous and mucous tissues in the wavelength range from 400 to 2000 nm , 2005 .

[15]  Yu Sun,et al.  Use of ambient light in remote photoplethysmographic systems: comparison between a high-performance camera and a low-cost webcam. , 2012, Journal of biomedical optics.

[16]  Toshiyo Tamura,et al.  Wearable Photoplethysmographic Sensors—Past and Present , 2014 .

[17]  P. Mannheimer,et al.  The Light–Tissue Interaction of Pulse Oximetry , 2007, Anesthesia and analgesia.

[18]  L. O. Svaasand,et al.  Remote plethysmographic imaging using ambient light. , 2008, Optics express.

[19]  Susan M Daly,et al.  ‘Go with the flow ’: A review of methods and advancements in blood flow imaging , 2013, Journal of biophotonics.

[20]  R. Romashko,et al.  A new look at the essence of the imaging photoplethysmography , 2015, Scientific Reports.

[21]  Tom Lister,et al.  Optical properties of human skin , 2012, Journal of biomedical optics.