A Synchronized Multi-Unit Wireless Platform for Long-Term Activity Monitoring

One of the objectives of the medicine is to modify patients’ ways of living. In this context, a key role is played by the diagnosis. When dealing with acquisition systems consisting of multiple wireless devices located in different parts of the body, it becomes fundamental to ensure synchronization between the individual units. This task is truly a challenge, so one aims to limit the complexity of the calculation and ensure long periods of operation. In fact, in the absence of synchronization, it is impossible to relate all the measurements coming from the different subsystems on a single time scale for the extraction of complex characteristics. In this paper, we first analyze in detail all the possible causes that lead to have a system that is not synchronous and therefore not usable. Then, we propose a firmware implementation strategy and a simple but effective protocol that guarantees perfect synchrony between the devices while keeping computational complexity low. The employed network has a star topology with a master/slave architecture. In this paper a new approach to the synchronization problem is introduced to guarantee a precise but not necessarily accurate synchronization between the units. In order to demonstrate the effectiveness of the proposed solution, a platform consisting of two different types of units has been designed and built. In particular, a nine Degrees of Freedom (DoF) Inertial Measurement Unit (IMU) is used in one unit while a nine-DoF IMU and all circuits for the analysis of the superficial Electromyography (sEMG) are present on the other unit. The system is completed by an Android app that acts as a user interface for starting and stopping the logging operations. The paper experimentally demonstrates that the proposed solution overcomes all the limits set out and it guarantees perfect synchronization of the single measurement, even during long-duration acquisitions. In fact, a less than 30 μ s time mismatch has been registered for a 24 h test, and the possibility to perform complex post-processing on the acquired data with a simple and effective system has been proven.

[1]  Shouqian Sun,et al.  A Low-Cost End-to-End sEMG-Based Gait Sub-Phase Recognition System , 2020, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[2]  James Parkinson,et al.  An essay on the shaking palsy. 1817. , 2002, The Journal of neuropsychiatry and clinical neurosciences.

[3]  Riccardo Gusella,et al.  The Accuracy of the Clock Synchronization Achieved by TEMPO in Berkeley UNIX 4.3BSD , 1987, IEEE Trans. Software Eng..

[4]  Athanasios V. Vasilakos,et al.  Body Area Networks: A Survey , 2010, Mob. Networks Appl..

[5]  Thomas Provot,et al.  Validation of a High Sampling Rate Inertial Measurement Unit for Acceleration During Running , 2017, Sensors.

[6]  Deborah Estrin,et al.  Proceedings of the 5th Symposium on Operating Systems Design and Implementation Fine-grained Network Time Synchronization Using Reference Broadcasts , 2022 .

[7]  Flaviu Cristian,et al.  Probabilistic clock synchronization , 1989, Distributed Computing.

[8]  G. Coviello,et al.  Multiple Synchronized Inertial Measurement Unit Sensor Boards Platform for Activity Monitoring , 2020, IEEE Sensors Journal.

[9]  Catherine Dehollain,et al.  Gait assessment in Parkinson's disease: toward an ambulatory system for long-term monitoring , 2004, IEEE Transactions on Biomedical Engineering.

[10]  Corrado Mencar,et al.  Data Stream Classification by Dynamic Incremental Semi-Supervised Fuzzy Clustering , 2019, Int. J. Artif. Intell. Tools.

[11]  I. Blazinsek,et al.  Enhancing the accuracy of standard embedded RTC module with random synchronization events and dynamic calibration , 2016 .

[12]  Sandro Fioretti,et al.  A Deep Learning Approach to EMG-Based Classification of Gait Phases during Level Ground Walking , 2019, Electronics.

[13]  Joan Daniel Prades,et al.  The Power of Models: Modeling Power Consumption for IoT Devices , 2015, IEEE Sensors Journal.