About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: a 3D zero-strain study.

The accurate measurement of local strain is necessary to study bone mechanics and to validate micro computed tomography (µCT) based finite element (FE) models at the tissue scale. Digital volume correlation (DVC) has been used to provide a volumetric estimation of local strain in trabecular bone sample with a reasonable accuracy. However, nothing has been reported so far for µCT based analysis of cortical bone. The goal of this study was to evaluate accuracy and precision of a deformable registration method for prediction of local zero-strains in bovine cortical and trabecular bone samples. The accuracy and precision were analyzed by comparing scans virtually displaced, repeated scans without any repositioning of the sample in the scanner and repeated scans with repositioning of the samples. The analysis showed that both precision and accuracy errors decrease with increasing the size of the region analyzed, by following power laws. The main source of error was found to be the intrinsic noise of the images compared to the others investigated. The results, once extrapolated for larger regions of interest that are typically used in the literature, were in most cases better than the ones previously reported. For a nodal spacing equal to 50 voxels (498 µm), the accuracy and precision ranges were 425-692 µε and 202-394 µε, respectively. In conclusion, it was shown that the proposed method can be used to study the local deformation of cortical and trabecular bone loaded beyond yield, if a sufficiently high nodal spacing is used.

[1]  F. Hild,et al.  Computation of full-field displacements in a scaffold implant using digital volume correlation and finite element analysis. , 2013, Medical engineering & physics.

[2]  Paul E Barbone,et al.  Digital Volume Correlation for Study of the Mechanics of Whole Bones. , 2012, Procedia IUTAM.

[3]  T. Keaveny,et al.  Yield strain behavior of trabecular bone. , 1998, Journal of biomechanics.

[4]  B. Bay,et al.  Digital volume correlation: Three-dimensional strain mapping using X-ray tomography , 1999 .

[5]  M. Bouxsein,et al.  Bone quality: where do we go from here? , 2003, Osteoporosis International.

[6]  A. A. Zadpoor,et al.  Full-field strain measurement and fracture analysis of rat femora in compression test. , 2013, Journal of biomechanics.

[7]  J. Nyman,et al.  Differences in the mechanical behavior of cortical bone between compression and tension when subjected to progressive loading. , 2009, Journal of the mechanical behavior of biomedical materials.

[8]  Marco Viceconti,et al.  Mechanical testing of bones: the positive synergy of finite–element models and in vitro experiments , 2010, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[9]  Alejandro F. Frangi,et al.  Efficient computational fluid dynamics mesh generation by image registration , 2007, Medical Image Anal..

[10]  A. C. Taylor,et al.  Experimental validation of a finite element model of the proximal femur using digital image correlation and a composite bone model. , 2011, Journal of biomechanical engineering.

[11]  P. Zysset,et al.  Damage accumulation in vertebral trabecular bone depends on loading mode and direction. , 2011, Journal of biomechanics.

[12]  Philipp Schneider,et al.  Deformable image registration and 3D strain mapping for the quantitative assessment of cortical bone microdamage. , 2012, Journal of the mechanical behavior of biomedical materials.

[13]  Egon Perilli,et al.  Application of the digital volume correlation technique for the measurement of displacement and strain fields in bone: a literature review. , 2014, Journal of biomechanics.

[14]  R. Müller,et al.  Towards validation of computational analyses of peri-implant displacements by means of experimentally obtained displacement maps , 2011, Computer methods in biomechanics and biomedical engineering.

[15]  Z. Yosibash,et al.  Patient-specific Finite-element Analyses of the Proximal Femur with Orthotropic Material Properties Validated , 2022 .

[16]  T. Keaveny,et al.  Dependence of yield strain of human trabecular bone on anatomic site. , 2001, Journal of biomechanics.

[17]  Fabio Baruffaldi,et al.  Volume to density relation in adult human bone tissue. , 2011, Journal of Biomechanics.

[18]  I. Sinclair,et al.  The application of digital volume correlation (DVC) to study the microstructural behaviour of trabecular bone during compression. , 2014, Journal of the mechanical behavior of biomedical materials.

[19]  E. Morgan,et al.  Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone. , 2007, Journal of biomechanics.

[20]  J. Tehranzadeh,et al.  Relationships between material properties and CT scan data of cortical bone with and without metastatic lesions. , 2003, Medical engineering & physics.

[21]  T M Keaveny,et al.  Nonlinear behavior of trabecular bone at small strains. , 2001, Journal of biomechanical engineering.

[22]  Fabio Baruffaldi,et al.  Mechanical testing of cancellous bone from the femoral head: experimental errors due to off-axis measurements. , 2007, Journal of biomechanics.

[23]  B. Bay,et al.  Comparison of the linear finite element prediction of deformation and strain of human cancellous bone to 3D digital volume correlation measurements. , 2006, Journal of biomechanical engineering.

[24]  D C Barber,et al.  Automatic segmentation of medical images using image registration: diagnostic and simulation applications , 2005, Journal of medical engineering & technology.

[25]  O. Johnell,et al.  Requirements for DXA for the management of osteoporosis in Europe , 2005, Osteoporosis International.

[26]  D. Hose,et al.  Measuring three‐dimensional strain distribution in tendon , 2013, Journal of microscopy.

[27]  Simin Li,et al.  Variability and anisotropy of mechanical behavior of cortical bone in tension and compression. , 2013, Journal of The Mechanical Behavior of Biomedical Materials.