Hydrodynamic focusing investigation in a micro-flow cytometer

Hydrodynamic focusing behavior is characterized by two fluids coflowing at different velocities inside a micro-flow cytometer. In this study, a two-fluid model has been established to describe the flow transport behavior and interaction of sample and sheath fluids. The analysis treats the sample and sheath fluids as two-dimensional, laminar, incompressible, and isothermal. The theoretical model comprises two groups of transient conservation equations of mass and momentum with consideration of the interfacial momentum exchange. The governing equations are solved numerically through an iterative SIMPLEC algorithm to determine the flow properties. Since the ratio of the sheath velocity to the sample velocity varies from 5 to 70, the predicted focusing width and length are in good agreement with the experimental data in the literature. In addition, the present study explored the hydrodynamic focusing flowfield as well as the pressure drop across a micro-flow cytometer and the time needed for the completion of one focusing event in detail. To enhance the understanding of hydrodynamic focusing in the design of cytometers, ten numerical experiments were conducted to examine the effects of the inner nozzle length, inner nozzle exit width, inner nozzle shape, and fluid properties on the width of the focused sample stream.

[1]  Donald A. Drew,et al.  The analysis of two-phase flow and heat transfer using a multidimensional, four field, two-fluid model , 2001 .

[2]  Donald A. Drew,et al.  Phase-distribution mechanisms in turbulent low-quality two-phase flow in a circular pipe , 1982, Journal of Fluid Mechanics.

[3]  Bubble size and system pressure effects on the phase distribution for two-phase turbulent bubbly flows , 2001 .

[4]  Richard T. Lahey,et al.  The analysis of phase separation and phase distribution phenomena using two-fluid models , 1990 .

[5]  J. Michael Ramsey,et al.  Microchip flow cytometry using electrokinetic focusing. , 1999, Analytical chemistry.

[6]  J. Greve,et al.  Two-color fluorescence in flow cytometry DNA sizing : Identification of single-molecule fluorescent probes , 1999 .

[7]  M Bergeron,et al.  Principles of flow cytometry. , 1995, Transfusion science.

[8]  Gwo-Bin Lee,et al.  Hydrodynamic Focusing for a Micromachined Flow Cytometer , 2001 .

[9]  Ryo Miyake,et al.  A development of micro sheath flow chamber , 1991, [1991] Proceedings. IEEE Micro Electro Mechanical Systems.

[10]  J. P. V. Doormaal,et al.  ENHANCEMENTS OF THE SIMPLE METHOD FOR PREDICTING INCOMPRESSIBLE FLUID FLOWS , 1984 .

[11]  Kukjin Chun,et al.  Fabrication of an electrostatic track-following micro actuator for hard disk drives using SOI wafer , 2001 .

[12]  Michael G. Ormerod,et al.  Flow Cytometry: A Practical Approach , 1994 .

[13]  S. Patankar Numerical Heat Transfer and Fluid Flow , 2018, Lecture Notes in Mechanical Engineering.

[14]  D. Drew,et al.  The analysis of void wave propagation in adiabatic monodispersed bubbly two-phase flows using an ensemble-averaged two-fluid model , 1999 .

[15]  J. Freedman,et al.  Applications of flow cytometry in the analysis of blood leukocytes. , 1995, Transfusion Science.

[16]  N. Sizto,et al.  Volumetric capillary cytometry: a new method for absolute cell enumeration. , 1996, Cytometry.

[17]  Mamoru Ishii,et al.  Two-fluid model and hydrodynamic constitutive relations , 1984 .

[18]  N. Zuber,et al.  Drag coefficient and relative velocity in bubbly, droplet or particulate flows , 1979 .

[19]  M. McClain,et al.  Flow cytometry of Escherichia coli on microfluidic devices. , 2001, Analytical chemistry.

[20]  Gwo-Bin Lee,et al.  Institute of Physics Publishing Journal of Micromechanics and Microengineering Micromachined Pre-focused 1 × N Flow Switches for Continuous Sample Injection , 2022 .

[21]  W. P. Ambrose,et al.  High-throughput flow cytometric DNA fragment sizing. , 2000, Analytical chemistry.

[22]  S. Acharya,et al.  Comparison of the Piso, Simpler, and Simplec Algorithms for the Treatment of the Pressure-Velocity Coupling in Steady Flow Problems , 1986 .

[23]  Howard M. Shapiro,et al.  Practical Flow Cytometry , 1985 .

[24]  H. Steen Flow cytometry of bacteria: glimpses from the past with a view to the future. , 2000, Journal of microbiological methods.

[25]  Dong-Chul Han,et al.  Plastic microchip flow cytometer based on 2- and 3-dimensional hydrodynamic flow focusing , 2003 .