Novel braking resistor models for transient stability enhancement in power grid system

Braking resistor (BR) is one of the effective methods to improve the transient stability of synchronous generators. In this work, two new braking resistor models, one consisting of thyristor rectifier and the other consisting of a combination of diode rectifier and chopper, are proposed, and their performance is compared with the existing thyristor controlled braking resistor. Comparison is made in terms of the speed performance indices, number of components used, heat loss and harmonics analysis for each proposed model and the existing model. The effectiveness of the proposed methodology is tested through Matlab/Simulink simulations considering both balanced and unbalanced temporary and permanent faults in a single generator power grid system. Simulation results indicate that the transient stability performance of the proposed methods is comparable to that of the existing model. Moreover, the proposed models use a single unit of BR that might lead to cost reduction of BR. Therefore, the proposed models can be considered as an alternative to the existing model for improving the transient stability of the power system.

[1]  W. Marsden I and J , 2012 .

[2]  In-Keun Yu Minimization of Shaft Torsional Oscillations by Fuzzy Controlled Braking Resistor Considering Communication Delay , 2007 .

[3]  Toshiaki Murata,et al.  Influence of Communication Delay on the Performance of Fuzzy Logic-Controlled Braking Resistor Against Transient Stability , 2008, IEEE Transactions on Control Systems Technology.

[4]  J. Beak,et al.  Re-using and re-rating older rectifiers with new DC/DC choppers , 2000, Record of Conference Papers. Industry Applications Society Forty-Seventh Annual Conference. 2000 Petroleum and Chemical Industry Technical Conference (Cat. No.00CH37112).

[5]  Graeme Burt,et al.  APPLYING SERIES BRAKING RESISTORS TO IMPROVE THE TRANSIENT STABILITY OF LOW INERTIA SYNCHRONOUS DISTRIBUTED GENERATORS , 2007 .

[6]  T. Murata,et al.  The effect of temperature rise of the fuzzy logic-controlled braking resistors on transient stability , 2004, IEEE Transactions on Power Systems.

[7]  J. F. Conroy,et al.  Low-voltage ride-through of a full converter wind turbine with permanent magnet generator , 2007 .

[8]  T. Murata,et al.  Augmentation of transient stability by fuzzy-logic controlled braking resistor in multi-machine power system , 2005, 2005 IEEE Russia Power Tech.

[9]  B. Umamaheswari,et al.  Electrical braking of large wind turbines , 2005 .

[10]  M.L. Shelton,et al.  Bonneville power administration 1400-MW braking resistor , 1975, IEEE Transactions on Power Apparatus and Systems.

[11]  Yixin Ni,et al.  An overview on transient stability control in modern power systems , 2006 .

[12]  Carson W. Taylor,et al.  Definition and Classification of Power System Stability , 2004 .

[13]  Y. Soma,et al.  A fuzzy logic controlled braking resistor scheme for stabilization of synchronous generator , 2001, IEMDC 2001. IEEE International Electric Machines and Drives Conference (Cat. No.01EX485).

[14]  A. S. Popp,et al.  Comparison of thyristor vs. chopper rectifiers in a common application , 2000, Record of Conference Papers. Industry Applications Society Forty-Seventh Annual Conference. 2000 Petroleum and Chemical Industry Technical Conference (Cat. No.00CH37112).

[15]  Mohd. Hasan Ali,et al.  Transient stability augmentation by fuzzy logic controlled braking resistor in multi-machine power system , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[16]  Junji Tamura,et al.  TRANSIENT STABILITY IMPROVEMENT BY FUZZY LOGIC-CONTROLLED BRAKING RESISTOR , 2005 .

[17]  P. Kundur,et al.  Definition and classification of power system stability IEEE/CIGRE joint task force on stability terms and definitions , 2004, IEEE Transactions on Power Systems.

[18]  H. M. Ellis,et al.  Dynamic Stability of the Peace River Transmission System , 1966 .

[19]  A.H.M.A. Rahim,et al.  A minimum-time based fuzzy logic dynamic braking resistor control for sub-synchronous resonance , 2004 .

[20]  T. Murata,et al.  Effect of coordination of optimal reclosing and fuzzy controlled braking resistor on transient stability during unsuccessful reclosing , 2006, IEEE Transactions on Power Systems.