Natural ventilation systems in 21st-century for near zero energy school buildings

Abstract Recently built school buildings present an increased air-tightness and have adopted mechanical ventilation systems, operating several hours daily to achieve adequate Indoor Air Quality. Nevertheless, in warm regions, the hours per year for which heating systems are required remain moderate. In these climates, natural ventilation systems present a viable alternative to the design of near Zero Energy Buildings maintaining indoor comfort conditions. In this paper, experimental tests are performed on two school buildings in southern Spain that comparatively analyse the effectiveness of air renewal by a mechanical ventilation system in comparison with a natural ventilation system. Indoor CO2, temperature and humidity levels are studied in terms of classroom occupation. Following the analysis, measured data is validated with running simulations in a third school building in which an NVS based on cross ventilation and stack effect is designed and tested. Results show that, by using a Natural Ventilation System, and even when heat losses due to winter operation are taken into account, the energy use over the academic year is clearly lower than when a Mechanical Ventilation System is used. The primary energy savings lie within the range of 18–33% with the natural ventilation system while maintaining classroom comfort levels.

[1]  Pawel Wargocki,et al.  Providing better thermal and air quality conditions in school classrooms would be cost-effective , 2013 .

[2]  Dong Yang,et al.  Dimensionless design approach, applicability and energy performance of stack-based hybrid ventilation for multi-story buildings , 2015 .

[3]  Dorota Anna Krawczyk,et al.  Theoretical and real effect of the school's thermal modernization—A case study , 2014 .

[4]  Burcin Becerik-Gerber,et al.  Building occupancy diversity and HVAC (heating, ventilation, and air conditioning) system energy efficiency , 2016 .

[5]  Yang Wang,et al.  Cooling energy efficiency and classroom air environment of a school building operated by the heat recovery air conditioning unit , 2014 .

[6]  Malcolm J. Cook,et al.  Natural Ventilation and Low Energy Cooling of Large, Non-Domestic Buildings – Four Case Studies , 2005 .

[7]  Danny H.W. Li,et al.  A comparison of global bioclimates in the 20th and 21st centuries and building energy consumption implications , 2014 .

[8]  Shuai Deng,et al.  How to evaluate performance of net zero energy building – A literature research , 2014 .

[9]  Ke Sun,et al.  A holistic passive design approach to optimize indoor environmental quality of a typical residential building in Hong Kong , 2016 .

[10]  Zied Driss,et al.  Numerical simulation and wind tunnel experiments on wind-induced natural ventilation in isolated building with patio , 2015 .

[11]  D. W. Etheridge,et al.  A perspective on fifty years of natural ventilation research , 2015 .

[12]  Patrick James,et al.  Naturally ventilated classrooms: An assessment of existing comfort models for predicting the thermal sensation and preference of primary school children , 2012 .

[13]  P. Ole Fanger,et al.  Human requirements in future air-conditioned environments , 2001 .

[14]  Ricardo M.S.F. Almeida,et al.  Indoor environmental quality of classrooms in Southern European climate , 2014 .

[15]  P. Fanger,et al.  Extension of the PMV model to non-air-conditioned buildings in warm climates , 2002 .

[16]  Yuehong Su,et al.  A review on wind driven ventilation techniques , 2008 .

[17]  Salvatore Carlucci,et al.  Impact of Different Thermal Comfort Models on Zero Energy Residential Buildings in Hot Climate , 2015 .

[18]  Lucinda Barrett,et al.  The impact of classroom design on pupils' learning: Final results of a holistic, multi-level analysis , 2015 .

[19]  M. Muselli,et al.  Natural cross ventilation in buildings on Mediterranean coastal zones , 2014 .

[20]  Azadeh Jafari,et al.  A study of a wind catcher assisted adsorption cooling channel for natural cooling of a 2-storey building , 2016 .

[21]  Ricardo M.S.F. Almeida,et al.  IEQ Assessment of Classrooms with an Optimized Demand Controlled Ventilation System , 2015 .

[22]  Ursula Eicker,et al.  Controlled natural ventilation for energy efficient buildings , 2013 .

[23]  Francesca Stazi,et al.  Indoor air quality and thermal comfort optimization in classrooms developing an automatic system for windows opening and closing , 2017 .

[24]  Kathryn B. Janda,et al.  Buildings don't use energy: people do , 2011 .

[25]  Yi Wang,et al.  Ventilation system type, classroom environmental quality and pupils' perceptions and symptoms , 2014 .

[26]  João Dias Carrilho,et al.  Towards sustainable, energy-efficient and healthy ventilation strategies in buildings: A review , 2016 .

[27]  La Directiva 2002/91/CE relativa a la eficiencia energética de los edificios , 2003 .

[28]  Nikola Mirkov,et al.  Indoor CO2 measurements in Serbian schools and ventilation rate calculation , 2014 .

[29]  Khairul Salleh Mohamed Sahari,et al.  Energy saving by integrated control of natural ventilation and HVAC systems using model guide for comparison , 2014 .

[30]  Jlm Jan Hensen,et al.  Analysis of the predicted effect of passive climate adaptation measures on energy demand for cooling and heating in a residential building , 2016 .

[31]  Leon R. Glicksman,et al.  Preliminary design method for naturally ventilated buildings using target air change rate and natural ventilation potential maps in the United States , 2015 .

[32]  Derek Clements-Croome,et al.  Ventilation rates in schools , 2008 .