Evaluation of Inter-System Variability in Liver Stiffness Measurements

AIM  The primary aim of this study was to determine the inter-system variability of liver stiffness measurements (LSMs) in patients with varying degrees of liver stiffness. The secondary aim was to determine the inter-observer variability of measurements. MATERIALS AND METHODS  21 individuals affected by chronic hepatitis C and 5 healthy individuals were prospectively enrolled. The assessment of LSMs was performed using six ultrasound (US) systems, four of which with point shear wave elastography (p-SWE) and two with 2 D shear wave elastography (2D-SWE) systems. The Fibroscan (Echosens, France) was used as the reference standard. Four observers performed the measurements in pairs (A-B, C-D). The agreement between different observers or methods was calculated using Lin's concordance correlation coefficient. The Bland-Altman limits of agreement (LOA) were calculated as well. RESULTS  There was agreement above 0.80 for all pairs of systems. The mean difference between the values of the systems with 2D-SWE technique was 1.54 kPa, whereas the maximum mean difference between the values of three out of four systems with the pSWE technique was 0.79 kPa. The intra-patient concordance for all systems was 0.89 (95 % CI: 0.83 - 0.94). Inter-observer agreement was 0.96 (95 % CI: 0.94 - 0.98) for the pair of observers A-B and 0.93 (95 % CI: 0.89 - 0.96) for the pair of observers C-D. CONCLUSION  The results of this study show that the agreement between LSMs performed with different US systems is good to excellent and the overall inter-observer agreement in "ideal conditions" is above 0.90 in expert hands.

[1]  Ioan Sporea,et al.  EFSUMB Guidelines and Recommendations on the Clinical Use of Liver Ultrasound Elastography, Update 2017 (Long Version) , 2017, Ultraschall in der Medizin - European Journal of Ultrasound.

[2]  Ioan Sporea,et al.  Intra- and interoperator reproducibility of acoustic radiation force impulse (ARFI) elastography--preliminary results. , 2012, Ultrasound in medicine & biology.

[3]  Tsuyoshi Shiina,et al.  WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 3: liver. , 2015, Ultrasound in medicine & biology.

[4]  Parth Parekh,et al.  Shear Wave Elastography for Evaluation of Liver Fibrosis , 2014, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[5]  Dario Conte,et al.  Reproducibility of transient elastography in the evaluation of liver fibrosis in patients with chronic liver disease , 2007, Gut.

[6]  Mirko D'Onofrio,et al.  Tissue quantification with acoustic radiation force impulse imaging: Measurement repeatability and normal values in the healthy liver. , 2010, AJR. American journal of roentgenology.

[7]  E. Cholongitas,et al.  Elastography for the diagnosis of severity of fibrosis in chronic liver disease: a meta-analysis of diagnostic accuracy. , 2011, Journal of hepatology.

[8]  V. de Lédinghen,et al.  EFSUMB Guidelines and Recommendations on the Clinical Use of Liver Ultrasound Elastography, Update 2017 (Short Version) , 2017, Ultraschall in der Medizin - European Journal of Ultrasound.

[9]  Carmine Tinelli,et al.  Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity. , 2012, European journal of radiology.

[10]  L. Lin,et al.  A concordance correlation coefficient to evaluate reproducibility. , 1989, Biometrics.

[11]  Douglas G. Altman,et al.  Practical statistics for medical research , 1990 .

[12]  L. Bolondi,et al.  Differences in liver stiffness values obtained with new ultrasound elastography machines and Fibroscan: A comparative study. , 2017, Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver.

[13]  G. Ferraioli,et al.  Point shear wave elastography method for assessing liver stiffness. , 2014, World journal of gastroenterology.

[14]  P. Janmey,et al.  Hepatic stellate cells and portal fibroblasts are the major cellular sources of collagens and lysyl oxidases in normal liver and early after injury. , 2013, American journal of physiology. Gastrointestinal and liver physiology.

[15]  Eva Herrmann,et al.  Liver fibrosis in viral hepatitis: noninvasive assessment with acoustic radiation force impulse imaging versus transient elastography. , 2009, Radiology.

[16]  J. Han,et al.  Shear Wave Elastography for Liver Stiffness Measurement in Clinical Sonographic Examinations , 2014, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[17]  Abdullah Alturki,et al.  RSNA/QIBA: Shear wave speed as a biomarker for liver fibrosis staging , 2013, 2013 IEEE International Ultrasonics Symposium (IUS).

[18]  N. Obuchowski,et al.  RSNA QIBA ultrasound shear wave speed Phase II phantom study in viscoelastic media , 2015, 2015 IEEE International Ultrasonics Symposium (IUS).

[19]  Christophe Aubé,et al.  Acoustic radiation force impulse: a new ultrasonographic technology for the widespread noninvasive diagnosis of liver fibrosis , 2010, European journal of gastroenterology & hepatology.

[20]  Laurent Milot,et al.  Inter- and intra-operator reliability and repeatability of shear wave elastography in the liver: a study in healthy volunteers. , 2013, Ultrasound in medicine & biology.

[21]  Jonathan Rubin,et al.  Elastography Assessment of Liver Fibrosis: Society of Radiologists in Ultrasound Consensus Conference Statement , 2016, Ultrasound quarterly.