Charnley wear model for validation of hip simulators' ball diameter versus polytetrafluoroethylene and polyethylene wear

Abstract Wear rates of polytetrafluoroethylene (PTFE) and polyethylene cups were compared in 9-channel and 12-channel simulators, using serum lubrication and gravimetric techniques for wear assessment. Cobalt-chromium (CoCr) and alumina ceramic femoral heads in 22-42 mm diameter range were used to validate simulator wear rates against clinical data. This was also the first study of three femoral head sizes evaluated concurrently in a simulator (with three replicate specimens) and also the first report in which any wear experiments were repeated. Fluid absorption artefacts were within ± 1 per cent of wear magnitude for PTFE and ± 8 per cent for polyethylene and were corrected for. Wear rates were linear as a function of test duration. Precision within each set of three cups was within ±6 per cent. The wear rates from experiments repeated over 15 months were reproducible to within ± 24 per cent. However, the magnitudes of the simulator wear rates were not clinically accurate, the PTFE wear rates (2843 mm3/106 cycles; 22 mm diameter) were over three times higher than in vivo, the polyethylene 30 to 50 per cent on the low side (23 mm3/106 cycles; 22 mm diameter). Volumetric wear rate increased with respect to size of femoral head and a linearly increasing relationship of 7-8 per cent/mm was evident with respect to femoral head diameter for both PTFE and polyethylene. These data compared well with the clinical data.

[1]  I C Clarke,et al.  Wear of Artificial Joint Materials IV , 1981 .

[2]  A. Hosseinian,et al.  Fluid-sorption phenomena in sterilized polyethylene acetabular prostheses. , 1985, Biomaterials.

[3]  Vesa Saikko Wear of polyethylene acetabular cups against zirconia femoral heads studied with a hip joint simulator , 1994 .

[4]  K. Markolf,et al.  Friction and wear properties of polymer, metal, and ceramic prosthetic joint materials evaluated on a multichannel screening device. , 1981, Journal of biomedical materials research.

[5]  J. Charnley,et al.  Rate of wear in total hip replacement. , 1975, Clinical orthopaedics and related research.

[6]  I C Clarke,et al.  Wear characteristics of UHMW polyethylene: a method for accurately measuring extremely low wear rates. , 1978, Journal of biomedical materials research.

[7]  H. McKellop,et al.  Degradation and Wear of Ultra-High-Molecular-Weight Polyethylene , 1985 .

[8]  D. Dowson,et al.  Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints. , 1994, Medical engineering & physics.

[9]  Duncan Dowson,et al.  An evaluation of the penetration of ceramic femoral heads into polyethylene acetabular cups , 1993 .

[10]  V O Saikko,et al.  Wear of the polyethylene acetabular cup. Metallic and ceramic heads compared in a hip simulator. , 1993, Acta orthopaedica Scandinavica.

[11]  K Ikeuchi,et al.  Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy. , 1991, Journal of biomedical materials research.

[12]  V O Saikko,et al.  Wear of the polyethylene acetabular cup. The effect of head material, head diameter, and cup thickness studied with a hip simulator. , 1995, Acta orthopaedica Scandinavica.

[13]  I. Paul,et al.  Wear mechanisms for ultrahigh molecular weight polyethylene in the total hip prosthesis , 1979 .

[14]  V O Saikko,et al.  Wear of polyethylene acetabular cups against alumina femoral heads. 5 prostheses compared in a hip simulator for 35 million walking cycles. , 1993, Acta orthopaedica Scandinavica.

[15]  B. Morrey,et al.  Effect of femoral head size on wear of the polyethylene acetabular component. , 1990, The Journal of bone and joint surgery. American volume.

[16]  P. Campbell,et al.  Isolation of predominantly submicron-sized UHMWPE wear particles from periprosthetic tissues. , 1995, Journal of biomedical materials research.