A New Variational Method for Erythrocyte Velocity Estimation in Wide-Field Imaging In Vivo

Measuring erythrocyte velocity in individual microvessels has important applications for biomedical and functional imaging. Recent multiphoton fluorescence microscopy approaches require injecting fluorescent tracers; moreover, only one or few vessels can be imaged at a time. To overcome these shortcomings, we used CCD-based optical imaging of intrinsic absorption changes in macroscopic vascular networks to record erythrocytes' trajectories over several mm2 of cortical surface. We then demonstrate the feasibility of erythrocyte velocity estimation from such wide-field data, using two robust, independent, algorithms. The first one is a recently published Radon transform-based algorithm that estimates erythrocyte velocity locally. We adapt it to data obtained in wide-field imaging and show, for the first time, its performance on such datasets. The second (“fasttrack”) algorithm is novel. It is based on global energy minimization techniques to estimate the full spatiotemporal erythrocytes' trajectories inside vessels. We test the two algorithms on both simulated and biological data, obtained in rat cerebral cortex in a spreading depression experiment. On vessels with medium-slow erythrocyte velocities both algorithms performed well, allowing their usage as benchmark one for another. However, our novel fasttrack algorithm outperformed the other one for higher velocities, as encountered in the arterial network.

[1]  A. Grinvald,et al.  REDUCED RETINAL BLOOD FLOW VELOCITY IN DIABETIC RETINOPATHY , 2010, Retina.

[2]  M. Moskowitz,et al.  Pronounced Hypoperfusion during Spreading Depression in Mouse Cortex , 2004, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[3]  R. Jain,et al.  Simultaneous measurement of RBC velocity, flux, hematocrit and shear rate in vascular networks in vivo , 2010 .

[4]  Anders M. Dale,et al.  Depth-resolved optical imaging and microscopy of vascular compartment dynamics during somatosensory stimulation , 2007, NeuroImage.

[5]  M. Moskowitz,et al.  Dynamic Imaging of Cerebral Blood Flow Using Laser Speckle , 2001, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[6]  Y. J. Tejwani,et al.  Robot vision , 1989, IEEE International Symposium on Circuits and Systems,.

[7]  Amiram Grinvald,et al.  High-resolution functional optical imaging: from the neocortex to the eye. , 2004, Ophthalmology clinics of North America.

[8]  M. Ducros,et al.  The Relationship between Blood Flow and Neuronal Activity in the Rodent Olfactory Bulb , 2007, The Journal of Neuroscience.

[9]  Stephen A. Billings,et al.  Model Estimation of Cerebral Hemodynamics Between Blood Flow and Volume Changes: A Data-Based Modeling Approach , 2009, IEEE Transactions on Biomedical Engineering.

[10]  J D Briers,et al.  Capillary Blood Flow Monitoring Using Laser Speckle Contrast Analysis (LASCA). , 1999, Journal of biomedical optics.

[11]  D. Kleinfeld,et al.  Two-Photon Imaging of Cortical Surface Microvessels Reveals a Robust Redistribution in Blood Flow after Vascular Occlusion , 2006, PLoS biology.

[12]  Jürgen Linseisen,et al.  THE INTERIOR , 2010 .

[13]  Kazuto Masamoto,et al.  Intracortical microcirculatory change induced by anesthesia in rat somatosensory cortex. , 2010, Advances in experimental medicine and biology.

[14]  J. Briers,et al.  Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging. , 2001, Physiological measurement.

[15]  A. Grinvald,et al.  A tandem-lens epifluorescence macroscope: Hundred-fold brightness advantage for wide-field imaging , 1991, Journal of Neuroscience Methods.

[16]  A Villringer,et al.  Separation of changes in light scattering and chromophore concentrations during cortical spreading depression in rats. , 1998, Optics letters.

[17]  E. Hillman,et al.  Ultra-fast multispectral optical imaging of cortical oxygenation, blood flow, and intracellular calcium dynamics. , 2009, Optics express.

[18]  W. Marsden I and J , 2012 .

[19]  Dai Fukumura,et al.  Simultaneous measurement of RBC velocity, flux, hematocrit and shear rate in tumor vascular networks , 2010, Nature Methods.

[20]  R. Buxton,et al.  Modeling the hemodynamic response to brain activation , 2004, NeuroImage.

[21]  Gert Cauwenberghs,et al.  Rapid determination of particle velocity from space-time images using the Radon transform , 2010, Journal of Computational Neuroscience.

[22]  Amiram Grinvald,et al.  Special report: Noninvasive multi-parameter functional optical imaging of the eye. , 2005, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.

[23]  Douglas C. Noll,et al.  Vascular dynamics and BOLD fMRI: CBF level effects and analysis considerations , 2006, NeuroImage.

[24]  T. Coleman,et al.  On the Convergence of Reflective Newton Methods for Large-scale Nonlinear Minimization Subject to Bounds , 1992 .

[25]  Olivier D. Faugeras,et al.  Cerebral blood flow recorded at high sensitivity in two dimensions using high resolution optical imaging , 2006, 3rd IEEE International Symposium on Biomedical Imaging: Nano to Macro, 2006..

[26]  Kevin Barraclough,et al.  I and i , 2001, BMJ : British Medical Journal.

[27]  Thomas F. Coleman,et al.  On the convergence of interior-reflective Newton methods for nonlinear minimization subject to bounds , 1994, Math. Program..

[28]  Thomas Deneux,et al.  Sift-based sequence registration and flow-based cortical vessel segmentation applied to high resolution optical imaging data , 2008, ISBI.

[29]  Amiram Grinvald,et al.  Functional imaging using the retinal function imager: Direct imaging of blood velocity, achieving fluorescein angiography-like images without any contrast agent, qualitative oximetry, and functional metabolic signals , 2009, Japanese Journal of Ophthalmology.

[30]  Thomas F. Coleman,et al.  An Interior Trust Region Approach for Nonlinear Minimization Subject to Bounds , 1993, SIAM J. Optim..

[31]  D. Kleinfeld,et al.  Fluctuations and stimulus-induced changes in blood flow observed in individual capillaries in layers 2 through 4 of rat neocortex. , 1998, Proceedings of the National Academy of Sciences of the United States of America.