Automated Field-In-Field (FIF) Plan Framework Combining Scripting Application Programming Interface and User-Executed Program for Breast Forward IMRT

Purpose: To develop an one-click option on treatment planning system that enables for the automated breast FIF planning by combining the Eclipse Scripting application programming interfaces and user-executed programming in Windows. Methods: Scripting application programming interfaces were designed to promote automation in clinical workflow associated with radiation oncology. However, scripting cannot provide all functions that users want to perform. Thus, a new framework proposes to integrate the benefits of the scripting application and user-executed programming for the automated field-in-field technique. We adopted the Eclipse Scripting applications, which provide an interface between treatment planning system server and client and enable for running the executed program to create dose clouds and adjust the planning parameters such as multi-leaf collimator placements and monitor unit values. Importantly, all tasks are designed to perform with one-click option on treatment planning system, including the automated pushback of the proposed plan to the treatment planning system. Results: The plans produced from the proposed framework were validated against the manual field-in-field plans with 40 retrospective breast patient cases in planning efficiency and plan quality. The elapsed time for running the framework was less than 1 minute, which significantly reduced the manual multi-leaf collimator/monitor unit adjustment time. It decreased the total planning time by more than 50%, relative to the manual field-in-field planning. In dosimetric aspects, the mean and maximum dose of the heart, lung, and whole breast did not exceed 1% deviation from the manual plans in most patient cases, while maintaining the target dose coverage and homogeneity index inside the target volume. From numerical analysis, the automated plans were demonstrated to be sufficiently close to the manual plans. Conclusion: The combination of scripting applications and user-executed programming for automated breast field-in-field planning accomplished a significant enhancement in planning efficiency without degrading the plan quality, relative to the manual field-in-field procedure.

[1]  F. Vicini,et al.  Optimizing breast cancer treatment efficacy with intensity-modulated radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[2]  S. Jolly,et al.  Intensity-modulated radiotherapy results in significant decrease in clinical toxicities compared with conventional wedge-based breast radiotherapy. , 2007, International journal of radiation oncology, biology, physics.

[3]  W. Woodward,et al.  Multileaf field-in-field forward-planned intensity-modulated dose compensation for whole-breast irradiation is associated with reduced contralateral breast dose: a phantom model comparison. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[4]  R. Prabhakar,et al.  Can field-in-field technique replace wedge filter in radiotherapy treatment planning: a comparative analysis in various treatment sites , 2008, Australasian Physics & Engineering Sciences in Medicine.

[5]  X. Li,et al.  Direct aperture optimization-based intensity-modulated radiotherapy for whole breast irradiation. , 2007, International journal of radiation oncology, biology, physics.

[6]  Eugene Wong,et al.  Automated IMRT planning with regional optimization using planning scripts , 2013, Journal of applied clinical medical physics.

[7]  C. Mayo,et al.  Forward-planned, multiple-segment, tangential fields with concomitant boost in the treatment of breast cancer. , 2004, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[8]  J. Zhu Generation of wedge‐shaped dose distributions through dynamic multileaf collimator dose delivery , 2005, Journal of applied clinical medical physics.

[9]  X Allen Li,et al.  Automated computer optimization for 3D treatment planning of breast irradiation. , 2008, Medical physics.

[10]  D D Leavitt,et al.  Dynamic wedge field techniques through computer-controlled collimator motion and dose delivery. , 1990, Medical physics.

[11]  X Allen Li,et al.  Technical Note: Development and performance of a software tool for quality assurance of online replanning with a conventional Linac or MR-Linac. , 2016, Medical physics.

[12]  D A Low,et al.  Dosimetry and clinical implementation of dynamic wedge. , 1995, International Journal of Radiation Oncology, Biology, Physics.

[13]  Lei Xing,et al.  Application programming in C# environment with recorded user software interactions and its application in autopilot of VMAT/IMRT treatment planning. , 2016, Journal of applied clinical medical physics.

[14]  Wayne Beckham,et al.  A multicenter randomized trial of breast intensity-modulated radiation therapy to reduce acute radiation dermatitis. , 2008, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[15]  Radhe Mohan,et al.  Dose sculpting with generalized equivalent uniform dose. , 2005, Medical physics.

[16]  Richard Symonds-Tayler,et al.  Randomised trial of standard 2D radiotherapy (RT) versus intensity modulated radiotherapy (IMRT) in patients prescribed breast radiotherapy. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[17]  A. De Gaetano,et al.  Forward planned intensity modulated radiotherapy (IMRT) for whole breast postoperative radiotherapy. Is it useful? When? , 2011, Journal of applied clinical medical physics.

[18]  P Hofman,et al.  An improved breast irradiation technique using three-dimensional geometrical information and intensity modulation. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[19]  J. Gibbons,et al.  Calculation of enhanced dynamic wedge factors for symmetric and asymmetric photon fields. , 1998, Medical physics.

[20]  J. Chapman,et al.  A comparative study of surface dose and dose distribution for intact breast following irradiation with field-in-field technique vs. the use of conventional wedges. , 2004, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[21]  J. Yarnold,et al.  The UK Standardisation of Breast Radiotherapy (START) Trial A of radiotherapy hypofractionation for treatment of early breast cancer: a randomised trial , 2008, The Lancet. Oncology.

[22]  R Mohan,et al.  Three dimensional conformal treatment planning with multileaf collimators. , 1995, International journal of radiation oncology, biology, physics.

[23]  D D Leavitt,et al.  Dosimetry measurement tools for commissioning enhanced dynamic wedge. , 1997, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.