A review of continuous glucose monitoring technology.

[1]  H Peter Chase,et al.  A randomized multicenter trial comparing the GlucoWatch Biographer with standard glucose monitoring in children with type 1 diabetes. , 2005, Diabetes care.

[2]  Bruce A Buckingham,et al.  Accuracy of the modified Continuous Glucose Monitoring System (CGMS) sensor in an outpatient setting: results from a diabetes research in children network (DirecNet) study. , 2005, Diabetes technology & therapeutics.

[3]  Claresa Levetan,et al.  Use of the Continuous Glucose Monitoring System to guide therapy in patients with insulin-treated diabetes: a randomized controlled trial. , 2004, Mayo Clinic proceedings.

[4]  Azadeh Shoaibi,et al.  The public health impact of the MiniMed Continuous Glucose Monitoring System (CGMS)-an assessment of the literature. , 2004, Diabetes technology & therapeutics.

[5]  A. Caduff,et al.  Impact of posture and fixation technique on impedance spectroscopy used for continuous and noninvasive glucose monitoring. , 2004, Diabetes technology & therapeutics.

[6]  D. Cox,et al.  Evaluating the accuracy of continuous glucose-monitoring sensors: continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data. , 2004, Diabetes care.

[7]  J. Mastrototaro,et al.  Alarms based on real-time sensor glucose values alert patients to hypo- and hyperglycemia: the guardian continuous monitoring system. , 2004, Diabetes technology & therapeutics.

[8]  S. Garg,et al.  Improved glucose excursions using an implantable real-time continuous glucose sensor in adults with type 1 diabetes. , 2004, Diabetes care.

[9]  P. Schaepelynck-Belicar,et al.  Improved metabolic control in diabetic adolescents using the continuous glucose monitoring system (CGMS). , 2003, Diabetes & metabolism.

[10]  Johnny Ludvigsson,et al.  Continuous subcutaneous glucose monitoring improved metabolic control in pediatric patients with type 1 diabetes: a controlled crossover study. , 2003, Pediatrics.

[11]  H. Chase,et al.  Use of the GlucoWatch biographer in children with type 1 diabetes. , 2003, Pediatrics.

[12]  A. Novials,et al.  The continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias in patients with type 1 and type 2 diabetes but is not better than frequent capillary glucose measurements for improving metabolic control. , 2003, Diabetes care.

[13]  Ronald Brazg,et al.  A continuous glucose sensor based on wired enzyme technology -- results from a 3-day trial in patients with type 1 diabetes. , 2003, Diabetes technology & therapeutics.

[14]  Stefano Zucchini,et al.  The glucose area under the profiles obtained with continuous glucose monitoring system relationships with HbA(lc) in pediatric type 1 diabetic patients. , 2002, Diabetes care.

[15]  R. Schiaffini,et al.  The Continuous Glucose Monitoring System (CGMS) in type 1 diabetic children is the way to reduce hypoglycemic risk , 2002, Diabetes/metabolism research and reviews.

[16]  Alberto Maran,et al.  Continuous subcutaneous glucose monitoring in diabetic patients: a multicenter analysis. , 2002, Diabetes care.

[17]  R. Potts,et al.  Glucose monitoring by reverse iontophoresis , 2002, Diabetes/metabolism research and reviews.

[18]  F. Kaufman,et al.  A pilot study of the continuous glucose monitoring system: clinical decisions and glycemic control after its use in pediatric type 1 diabetic subjects. , 2001, Diabetes care.

[19]  H. Chase,et al.  Continuous subcutaneous glucose monitoring in children with type 1 diabetes. , 2001, Pediatrics.

[20]  J. Mastrototaro,et al.  Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use. , 2000, Diabetes technology & therapeutics.

[21]  J. Mastrototaro,et al.  Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: a pilot study. , 1999, Diabetes research and clinical practice.