Toward true 3D visualization of active catheters using compressed sensing

A crucial requirement in MR‐guided interventions is the visualization of catheter devices in real time. However, true 3D visualization of the full length of catheters has hitherto been impossible given scan time constraints. Compressed sensing (CS) has recently been proposed as a method to accelerate MR imaging of sparse objects. Images acquired with active interventional devices exhibit a high CNR and are inherently sparse, therefore rendering CS ideally suited for accelerating data acquisition. A framework for true visualization of active catheters in 3D is proposed employing CS to gain high undersampling factors making real‐time applications feasible. Constraints are introduced taking into account prior knowledge of catheter geometry and catheter motion over time to improve and accelerate image reconstruction. The potential of the method is demonstrated using computer simulations and phantom experiments and in vivo feasibility is demonstrated in a pig experiment. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.

[1]  Shelton D Caruthers,et al.  Fluorine cardiovascular magnetic resonance angiography in vivo at 1.5 T with perfluorocarbon nanoparticle contrast agents. , 2007, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[2]  Jonathan M Sorger,et al.  Real-time volume rendered MRI for interventional guidance. , 2002, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[3]  Dana C Peters,et al.  Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter‐only views , 2003, Magnetic resonance in medicine.

[4]  E. B. Carlson,et al.  Interventional cardiac catheterization. , 1985, Investigative radiology.

[5]  Peter Boesiger,et al.  Compressed sensing in dynamic MRI , 2008, Magnetic resonance in medicine.

[6]  F. Korosec,et al.  Real-time MR imaging-guided passive catheter tracking with use of gadolinium-filled catheters. , 2000, Journal of vascular and interventional radiology : JVIR.

[7]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[8]  Tobias Schaeffter,et al.  Accelerating the Nonequispaced Fast Fourier Transform on Commodity Graphics Hardware , 2008, IEEE Transactions on Medical Imaging.

[9]  Ogan Ocali,et al.  Intravascular magnetic resonance imaging using a loopless catheter antenna , 1997, Magnetic resonance in medicine.

[10]  E. McVeigh,et al.  Minimizing RF heating of conducting wires in MRI , 2007, Magnetic resonance in medicine.

[11]  E. McVeigh,et al.  Real-time, Interactive MRI for cardiovascular interventions. , 2005, Academic radiology.

[12]  S. Souza,et al.  Real‐time position monitoring of invasive devices using magnetic resonance , 1993, Magnetic resonance in medicine.

[13]  M. Ladd,et al.  Reduction of resonant RF heating in intravascular catheters using coaxial chokes , 2000, Magnetic Resonance in Medicine.

[14]  J. Debatin,et al.  Active MR visualization of a vascular guidewire in vivo , 1998, Journal of magnetic resonance imaging : JMRI.

[15]  Peter Kellman,et al.  Real‐time accelerated interactive MRI with adaptive TSENSE and UNFOLD , 2003, Magnetic resonance in medicine.

[16]  Maythem Saeed,et al.  Endovascular interventional MRI , 2005, Journal of magnetic resonance imaging : JMRI.

[17]  Volkmar Schulz,et al.  Transmission line for improved RF safety of interventional devices , 2005, Magnetic resonance in medicine.

[18]  E. Catmull,et al.  A CLASS OF LOCAL INTERPOLATING SPLINES , 1974 .

[19]  D. Hill,et al.  Cardiac catheterisation guided by MRI in children and adults with congenital heart disease , 2003, The Lancet.

[20]  M A Viergever,et al.  Visualization of dedicated catheters using fast scanning techniques with potential for MR‐guided vascular interventions , 1996, Magnetic resonance in medicine.

[21]  Reza Razavi,et al.  Catheter tracking and visualization using 19F nuclear magnetic resonance , 2004, Magnetic resonance in medicine.

[22]  Namrata Vaswani,et al.  Kalman filtered Compressed Sensing , 2008, 2008 15th IEEE International Conference on Image Processing.

[23]  Peter Boesiger,et al.  Image‐based tracking of optically detunable parallel resonant circuits , 2003, Magnetic resonance in medicine.

[24]  Holger Timinger,et al.  Motion compensation for interventional navigation on 3D static roadmaps based on a dynamic motion model , 2004, CARS.

[25]  L W Bartels,et al.  Endovascular interventional magnetic resonance imaging. , 2003, Physics in medicine and biology.

[26]  Emmanuel J. Candès,et al.  Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information , 2004, IEEE Transactions on Information Theory.

[27]  Joel A. Tropp,et al.  Signal Recovery From Random Measurements Via Orthogonal Matching Pursuit , 2007, IEEE Transactions on Information Theory.

[28]  G. A. Watson,et al.  A class of methods for fitting a curve or surface to data by minimizing the sum of squares of orthogonal distances , 2003 .

[29]  David L Donoho,et al.  NMR data processing using iterative thresholding and minimum l(1)-norm reconstruction. , 2007, Journal of magnetic resonance.

[30]  Kawal S. Rhode,et al.  A system for real-time XMR guided cardiovascular intervention , 2005, IEEE Transactions on Medical Imaging.

[31]  Vivek Muthurangu,et al.  Visualization and tracking of an inflatable balloon catheter using SSFP in a flow phantom and in the heart and great vessels of patients , 2004, Magnetic resonance in medicine.

[32]  H. K. Charles,et al.  Catheter‐tracking FOV MR fluoroscopy , 1998, Magnetic resonance in medicine.