Tracking the scapula using the scapula locator with and without feedback from pressure-sensors: A comparative study.

BACKGROUND The scapula locator method has associated intra-observer and inter-observer errors caused by the dependency on the observer to locate the scapular landmarks. The potential effect of the pressures applied by the observer on the measured scapular kinematics when this method is used has also been overlooked so far. The aim of this study was to investigate the effect of using feedback on the pressures applied on the scapula using the locator on the intra-observer and inter-observer reliabilities of the method as well as on the kinematics obtained using this method. METHODS Three observers tracked the scapular motion of the dominant shoulder of each subject using the locator with no reference to pressure-feedback for three trials of bilateral elevation in the scapular plane and using the locator with pressure-feedback for three other trials. Variations between the measurements obtained were used to calculate the intra-observer errors and variations between the measurements obtained by the three observers for the same subject were used to calculate inter-observer errors. Repeated-measures ANOVA tests were used to look at differences between the two methods in terms of intra-observer and inter-observer errors and scapular kinematics. FINDINGS Using pressure-feedback reduced the intra-observer errors but had no effect on the inter-observer errors. Different scapular kinematics was measured using the two methods. INTERPRETATIONS Pressure-feedback improves the reliability of the scapula locator method. Differences in the scapular kinematics suggest that unregulated pressures have an effect on the physiological scapular motion.

[1]  G R Johnson,et al.  The measurement of three dimensional scapulohumeral kinematics--a study of reliability. , 1999, Clinical biomechanics.

[2]  Ray Fitzpatrick,et al.  The Oxford shoulder score revisited , 2007, Archives of Orthopaedic and Trauma Surgery.

[3]  Aliah F. Shaheen Tracking scapular movement , 2010 .

[4]  Jaap Harlaar,et al.  Recording scapular motion using an acromion marker cluster. , 2009, Gait & posture.

[5]  J. D. de Groot,et al.  The variability of shoulder motions recorded by means of palpation. , 1997, Clinical biomechanics.

[6]  Jurriaan H. de Groot The variability of shoulder motions recorded by means of palpation. , 1997 .

[7]  A R Karduna,et al.  Dynamic measurements of three-dimensional scapular kinematics: a validation study. , 2001, Journal of biomechanical engineering.

[8]  J. D. de Groot,et al.  Comparison between tripod and skin-fixed recording of scapular motion. , 2007, Journal of biomechanics.

[9]  Glenohumeral subluxation, scapula resting position, and scapula rotation after stroke: a noninvasive evaluation. , 2001, Archives of physical medicine and rehabilitation.

[10]  A. L. Wallace,et al.  Glenohumeral motion: review of measurement techniques , 2007, Knee Surgery, Sports Traumatology, Arthroscopy.

[11]  Bryan Buchholz,et al.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. , 2005, Journal of biomechanics.

[12]  Andreas Kontaxis,et al.  Adaptation of scapula lateral rotation after reverse anatomy shoulder replacement , 2008, Computer methods in biomechanics and biomedical engineering.

[13]  C.G.M. Meskers,et al.  3D shoulder position measurements using a six-degree-of-freedom electromagnetic tracking device. , 1998, Clinical biomechanics.