Dynamic four-dimensional microscope system with automated background leveling

This paper describes recent advances in developing an automatic background leveling algorithm for a new, novel interference microscope system and presents images and data of live biological samples. The specially designed optical system enables instantaneous 4-dimensional video measurements of dynamic motions within and among live cells without the need for contrast agents. "Label-free" measurements of biological objects in reflection using harmless light levels are possible without the need for scanning and vibration isolation. This instrument utilizes a pixelated phase mask enabling simultaneous measurement of multiple interference patterns taking advantage of the polarization properties of light enabling phase image movies in real time at video rates to track dynamic motions and volumetric changes. Optical thickness data are derived from phase images. This data is processed with an automatic background leveling routine which separates the objects from the background by thresholding the calculated gradient magnitude of the optical thickness data. Low-order Zernike surfaces are fit to the unmasked background pixels and the resulting background shape is removed. This method effectively eliminates background shape for datasets containing both large and small objects. By applying this method to many sequential frames, it results in all the frames having the same mean background value across all frames which is essential for quantitatively montoring time-dependent processes.

[1]  P. Walker,et al.  Semiautomated method for noise reduction and background phase error correction in MR phase velocity data , 1993, Journal of magnetic resonance imaging : JMRI.

[2]  Jürgen Beuthan,et al.  Optical phase measurements on biological cells , 2000 .

[3]  Ibrahim Abdulhalim,et al.  Competence between spatial and temporal coherence in full field optical coherence tomography and interference microscopy , 2006 .

[4]  E. H. Linfoot Principles of Optics , 1961 .

[5]  A. Mahadevan-Jansen,et al.  Automated Method for Subtraction of Fluorescence from Biological Raman Spectra , 2003, Applied spectroscopy.

[6]  Katherine Creath,et al.  Dynamic phase imaging for in vitro process monitoring and cell tracking , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  Katherine Creath,et al.  Dynamic visible interferometric measurement of thermal fields around living biological objects , 2004, SPIE Optics + Photonics.

[8]  Sen Han,et al.  High throughput cell nanomechanics with mechanical imaging interferometry , 2008, Nanotechnology.

[9]  D. Malacara Optical Shop Testing , 1978 .

[10]  B. Bhushan,et al.  An Optical Profilometer for Surface Characterization of Magnetic Media , 1984 .

[11]  D. Malacara,et al.  Interferogram Analysis for Optical Testing , 2018 .

[12]  G E Sommargren,et al.  Optical heterodyne profilometry. , 1981, Applied optics.

[13]  Gangjun Liu,et al.  Quantitative phase evaluation of dynamic changes on cell membrane during laser microsurgery. , 2008, Journal of biomedical optics.

[14]  Emily Seeley,et al.  Dual-wavelength digital holographic imaging with phase background subtraction , 2012 .

[15]  Katherine Creath,et al.  Dynamic phase imaging and processing of moving biological organisms , 2012, Photonics West - Biomedical Optics.

[16]  V. Ryabukho,et al.  Longitudinal pure spatial coherence of a light field with wide frequency and angular spectra. , 2005, Optics letters.

[17]  Katherine Creath,et al.  Dynamic quantitative phase images of pond life, insect wings, and in vitro cell cultures , 2010, Optical Engineering + Applications.

[18]  Graham Dunn,et al.  An image processing system for cell behaviour studies in subconfluent cultures , 1995 .

[19]  D Zicha,et al.  Phase-shifting interference microscopy applied to the analysis of cell behaviour. , 1993, Symposia of the Society for Experimental Biology.

[20]  Joan S. Weszka,et al.  A survey of threshold selection techniques , 1978 .

[21]  C. Delisle,et al.  Shearing interferometer for phase shifting interferometry with polarization phase shifter. , 1985, Applied optics.

[22]  Katherine Creath,et al.  Dynamic phase imaging utilizing a 4-dimensional microscope system , 2011, BiOS.

[23]  Bing Zhao,et al.  Quantitative phase measurements using optical quadrature microscopy. , 2008, Applied optics.

[24]  Matt Novak,et al.  Analysis of a micropolarizer array-based simultaneous phase-shifting interferometer. , 2005, Applied optics.

[25]  D. Brenner,et al.  Phase-based cell imaging techniques for microbeam irradiations , 2005 .

[26]  James C. Wyant,et al.  Pixelated Mask Spatial Carrier Phase Shifting Interferometry: Algorithms and Associated Errors , 2005 .

[27]  S. D. Yanowitz,et al.  A new method for image segmentation , 1988, [1988 Proceedings] 9th International Conference on Pattern Recognition.

[28]  M S Feld,et al.  Phase-referenced interferometer with subwavelength and subhertz sensitivity applied to the study of cell membrane dynamics. , 2001, Optics letters.

[29]  C A Dimarzio,et al.  Three-dimensional images generated by quadrature interferometry. , 1998, Optics letters.

[30]  A. Shtil,et al.  Quantitative real-time analysis of nucleolar stress by coherent phase microscopy. , 2008, Journal of biomedical optics.

[31]  James C. Wyant,et al.  Surface Profilers, Multiple Wavelength, and White Light Intereferometry , 2006 .

[32]  K. Creath V Phase-Measurement Interferometry Techniques , 1988 .

[33]  G. Popescu Quantitative phase imaging of nanoscale cell structure and dynamics. , 2008, Methods in cell biology.