Recent approaches to ameliorate selectivity and sensitivity of enzyme based cholesterol biosensors: a review

Abstract The healthcare area is often reluctant to execute new technology unless they are proven to be safe, constructive and secure. Eventually, an aspiration stands for providing point-of-care testing service to allow a better estimation of the biochemical levels of a patient that entails an insistent remedial action. With increasing mortality rate due to cardiovascular diseases (CVDs) in present scenario, it has become the need of hour to develop more advance methods for their diagnosis, so that it can be determined at sensitive levels and can be prevented from being fatal. Elevated level of cholesterol in blood stream is one of the utmost risk factors which lead to CVDs. Discernible from the vast research in this field, worth of cholesterol biosensors is already recognized and flourished in the clinical analysis of brain and cardiac vascular diseases. It necessitates unremitting progress in the development of biosensing technology towards fabrication, miniaturization and multiplexing ability of cholesterol quantification devices so that they can endow with lab-on-chip-analysis systems to the medical field. Different strategies have been meticulously explored for the engineering of cholesterol biosensors utilizing nanocomposites, conducting polymers, nanotubes and nanoparticles. Foremost, this article reviews the contemporary evolution in cholesterol biosensors, which encompass various strategies for immobilization of enzymes and roles of various matrices and artificial mediators used for the biosensor fabrication. Still there remains an enormous challenge to congregate the demands of performance and yield in a cost effective manner for its application in successful treatments of CVDs.

[1]  J. Pingarrón,et al.  Graphite-teflon composite bienzyme electrodes for the determination of cholesterol in reversed micelles. Application to food samples. , 2001, Analytical chemistry.

[2]  Pulickel M. Ajayan,et al.  Carbon nanotube electrode for oxidation of dopamine , 1996 .

[3]  Björn Persson,et al.  Amperometric glucose sensors based on immobilized glucose-oxidizing enzymes and chemically modified electrodes , 1991 .

[4]  A. Vrielink Cholesterol oxidase: structure and function. , 2010, Sub-cellular biochemistry.

[5]  M. Kroll,et al.  Application of Streptomyces and Brevibacterium cholesterol oxidase for total serum cholesterol assay by the enzymatic kinetic method. , 2006, Clinica chimica acta; international journal of clinical chemistry.

[6]  C. R. Raj,et al.  Development of an Amperometric Cholesterol Biosensor Based on Graphene-Pt Nanoparticle Hybrid Material , 2010 .

[7]  Sumitra Datta,et al.  Enzyme immobilization: an overview on techniques and support materials , 2012, 3 Biotech.

[8]  Javier Rodríguez,et al.  Nanotechnology: A Tool for Improved Performance on Electrochemical Screen-Printed (Bio)Sensors , 2009, J. Sensors.

[9]  Vasillios N. Psychoyios,et al.  Potentiometric Cholesterol Biosensor Based on ZnO Nanowalls and Stabilized Polymerized Lipid Film , 2013 .

[10]  S. F. D’souza,et al.  An amperometric bienzymatic cholesterol biosensor based on functionalized graphene modified electrode and its electrocatalytic activity towards total cholesterol determination. , 2012, Talanta.

[11]  J. Vidal,et al.  Amperometric cholesterol biosensor based on in situ reconstituted cholesterol oxidase on an immobilized monolayer of flavin adenine dinucleotide cofactor. , 2004, Analytical biochemistry.

[12]  John P. Hart,et al.  Fabrication and characterization of a screen-printed, disposable, amperometric cholesterol biosensor , 1994 .

[13]  Nicole Jaffrezic-Renault,et al.  Amperometric enzyme biosensors: Past, present and future , 2008 .

[14]  S. Ramaprabhu,et al.  Non-Enzymatic Glucose and Cholesterol Biosensors Based on Silica Coated Nano Iron Oxide Dispersed Multiwalled Carbon Nanotubes , 2011, 2011 International Conference on Nanoscience, Technology and Societal Implications.

[15]  Xia Zhong,et al.  Bi-pseudoenzyme synergetic catalysis to generate a coreactant of peroxydisulfate for an ultrasensitive electrochemiluminescence-based cholesterol biosensor. , 2014, Biosensors & bioelectronics.

[16]  M. Moreno-Bondi,et al.  Free cholesterol fiber-optic biosensor for serum samples with simplex optimization. , 1997, Biosensors & bioelectronics.

[17]  L. Hart,et al.  One-minute electrochemical enzymic assay for cholesterol in biological materials. , 1981, Clinical chemistry.

[18]  B Danielsson,et al.  Calorimetric biosensors. , 1991, Biochemical Society transactions.

[19]  M. Kratz Dietary cholesterol, atherosclerosis and coronary heart disease. , 2005, Handbook of experimental pharmacology.

[20]  L. Gorton,et al.  Amperometric biosensor for glutamate using prussian blue-based "artificial peroxidase" as a transducer for hydrogen peroxide. , 2000, Analytical chemistry.

[21]  P. Solanki,et al.  Cholesterol biosensor based on amino-undecanethiol self-assembled monolayer using surface plasmon resonance technique. , 2007, Langmuir : the ACS journal of surfaces and colloids.

[22]  C. Pundir,et al.  Biosensor based on enzyme coupled PVC reaction cell for electrochemical measurement of serum total cholesterol , 2009 .

[23]  J. Vidal,et al.  Development of a Platinized and Ferrocene-Mediated Cholesterol Amperometric Biosensor Based on Electropolymerization of Polypyrrole in a Flow System , 2002, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[24]  Y. Ergun,et al.  Electrochemical and optical properties of a conducting polymer and its use in a novel biosensor for the detection of cholesterol , 2015 .

[25]  B. D. Malhotra,et al.  Immobilization of cholesterol oxidase and potassium ferricyanide on dodecylbenzene sulfonate ion‐doped polypyrrole film , 2001 .

[26]  Runu Chakraborty,et al.  Development of cholesterol biosensor based on immobilized cholesterol esterase and cholesterol oxidase on oxygen electrode for the determination of total cholesterol in food samples. , 2007, Bioelectrochemistry.

[27]  Lucia Gardossi,et al.  Understanding enzyme immobilisation. , 2009, Chemical Society reviews.

[28]  P. Goswami,et al.  Covalent immobilization of cholesterol oxidase on self-assembled gold nanoparticles for highly sensitive amperometric detection of cholesterol in real samples. , 2011, Biosensors & bioelectronics.

[29]  Zhiwei Zhao,et al.  ZnO-Based Amperometric Enzyme Biosensors , 2010, Sensors.

[30]  Xiliang Luo,et al.  Application of Nanoparticles in Electrochemical Sensors and Biosensors , 2006 .

[31]  P. Fu,et al.  Enzymatic determination of total serum cholesterol. , 1974, Clinical chemistry.

[32]  Laurent Francis,et al.  State of the Art in Biosensors - General Aspects , 2013 .

[33]  Y. Chai,et al.  Electrochemistry of cholesterol biosensor based on a novel Pt-Pd bimetallic nanoparticle decorated graphene catalyst. , 2013, Talanta.

[34]  R. Srivastava,et al.  Cholesterol biosensors based on oxygen sensing alginate‐silica microspheres , 2011, Biotechnology and bioengineering.

[35]  Rahul Singhal,et al.  Immobilization of cholesterol esterase and cholesterol oxidase onto sol-gel films for application to cholesterol biosensor. , 2007, Analytica chimica acta.

[36]  Muamer Dervisevic,et al.  Amperometric cholesterol biosensor based on reconstituted cholesterol oxidase on boronic acid functional conducting polymers , 2016 .

[37]  S. Kuwabata,et al.  Electrochemical oxidation of cholesterol catalyzed by cholesterol oxidase with use of an artificial electron mediator. , 1997, Analytical chemistry.

[38]  I. Lipinska,et al.  High-density lipoproteins and atherosclerosis. , 1982, The New England journal of medicine.

[39]  Meihe Zhang,et al.  A biosensor for cholesterol based on gold nanoparticles-catalyzed luminol electrogenerated chemiluminescence. , 2012, Biosensors & bioelectronics.

[40]  Aicheng Chen,et al.  High-performance electrochemical biosensor for the detection of total cholesterol. , 2011, Biosensors & bioelectronics.

[41]  R. Sahney,et al.  A Conductometric Cholesterol Sensor Based on the Permeability Effect on BLM and its Application in Clinical Analysis , 2006 .

[42]  C. R. Treadwell,et al.  Enzymatic synthesis and hydrolysis of cholesterol esters. , 1968, Methods of biochemical analysis.

[43]  Suman,et al.  Preparation of a reusable enzyme strip for determination of serum cholesterol , 2005 .

[44]  N. Urano,et al.  Enzyme sensor system for determination of total cholesterol in fish plasma , 2003 .

[45]  Magnus Willander,et al.  Potentiometric cholesterol biosensor based on ZnO nanorods chemically grown on Ag wire , 2010 .

[46]  Jianrong Chen,et al.  Nanotechnology and biosensors. , 2004, Biotechnology advances.

[47]  N. Murr,et al.  Amperometric determination of cholesterol in serum with use of a renewable surface peroxidase electrode , 1995 .

[48]  Cholesterol Biosensor Based on MWCNTs-MnO 2 Nanoparticles Using FFT Continuous Cyclic Voltammetry , 2010 .

[49]  R. Yuan,et al.  Highly-sensitive cholesterol biosensor based on platinum-gold hybrid functionalized ZnO nanorods. , 2012, Talanta.

[50]  G. Li,et al.  Study of carbon nanotube modified biosensor for monitoring total cholesterol in blood. , 2005, Biosensors & bioelectronics.

[51]  P. Solanki,et al.  Application of Self-Assembled Monolayer of Carboxy-1-Decanthiol for Cholesterol Biosensor , 2006, 2006 International Conference on Biomedical and Pharmaceutical Engineering.

[52]  Plamen Atanasov,et al.  Enzyme‐catalyzed direct electron transfer: Fundamentals and analytical applications , 1997 .

[53]  Yamini Satyawali,et al.  Enzyme immobilization on/in polymeric membranes: status, challenges and perspectives in biocatalytic membrane reactors (BMRs) , 2011 .

[54]  B. D. Malhotra,et al.  Amperometric cholesterol biosensor based on immobilized cholesterol esterase and cholesterol oxidase on conducting polypyrrole films , 2004 .

[55]  H. Ahn,et al.  Association between Metabolic Components and Subclinical Atherosclerosis in Korean Adults , 2012, Korean journal of family medicine.

[56]  Kuo-Chuan Ho,et al.  Fabricating an Amperometric Cholesterol Biosensor by a Covalent Linkage between Poly(3-thiopheneacetic acid) and Cholesterol Oxidase , 2009, Sensors.

[57]  B. Lim,et al.  A cholesterol biosensor based on a bi-enzyme immobilized on conducting poly(thionine) film , 2014 .

[58]  Shen-ming Chen,et al.  Fabrication of a Cholesterol Biosensor Based on Cholesterol Oxidase and Multiwall Carbon Nanotube Hybrid Composites , 2011, International Journal of Electrochemical Science.

[59]  A. Gopalan,et al.  Development of a stable cholesterol biosensor based on multi-walled carbon nanotubes-gold nanoparticles composite covered with a layer of chitosan-room-temperature ionic liquid network. , 2009, Biosensors & bioelectronics.

[60]  Jianbin Zheng,et al.  Selective determination of cholesterol based on cholesterol oxidase-alkaline phosphatase bienzyme electrode. , 2012, The Analyst.

[61]  J. Harris Cholesterol Binding and Cholesterol Transport Proteins , 2010 .

[62]  B. Krajewska Application of chitin- and chitosan-based materials for enzyme immobilizations: a review , 2004 .

[63]  M. Nasu,et al.  Endpoint colorimetric method for assaying total cholesterol in serum with cholesterol dehydrogenase. , 1999, Clinical chemistry.

[64]  S. Minteer,et al.  Enzyme Immobilization in Biotechnology , 2008 .

[65]  Daniel I. C. Wang,et al.  Immobilization of l-lactate dehydrogenase on magnetic nanoclusters for chiral synthesis of pharmaceutical compounds , 2009 .

[66]  A. Gopalan,et al.  Fabrication of a novel dual mode cholesterol biosensor using titanium dioxide nanowire bridged 3D graphene nanostacks. , 2016, Biosensors & bioelectronics.

[67]  R. Chauhan,et al.  Gold-Nanoparticle Decorated Graphene-Nanostructured Polyaniline Nanocomposite-Based Bienzymatic Platform for Cholesterol Sensing , 2012 .

[68]  D. M. Amundson,et al.  Fluorometric method for the enzymatic determination of cholesterol. , 1999, Journal of biochemical and biophysical methods.

[69]  M. Rahman,et al.  Highly-sensitive cholesterol biosensor based on well-crystallized flower-shaped ZnO nanostructures. , 2009, Talanta.

[70]  A. Raftery,et al.  A Simplified Spectrophotometric Method for Determination of Total and Esterified Cholesterol with Tomatine. , 1963 .

[71]  P. Solanki,et al.  Zinc oxide nanoparticles-chitosan composite film for cholesterol biosensor. , 2008, Analytica chimica acta.

[72]  L. Toppare,et al.  A novel conducting copolymer: Investigation of its matrix properties for cholesterol biosensor applications , 2013 .

[73]  C S Pundir,et al.  Biosensors: Future Analytical Tools , 2007 .

[74]  P. Solanki,et al.  Mediator free cholesterol biosensor based on self-assembled monolayer platform. , 2012, The Analyst.

[75]  Audrey Sassolas,et al.  Immobilization strategies to develop enzymatic biosensors. , 2012, Biotechnology advances.

[76]  M. Vaseem,et al.  Ultra-sensitive cholesterol biosensor based on low-temperature grown ZnO nanoparticles , 2009 .

[77]  Vikas,et al.  Fabrication of Pt based amperometric cholesterol biosensor using cellulose acetate membrane , 2008 .

[78]  A. Tuantranont,et al.  Fast cholesterol detection using flow injection microfluidic device with functionalized carbon nanotubes based electrochemical sensor. , 2010, Biosensors & bioelectronics.

[79]  S. Uchiyama,et al.  Polymers for Biosensors Construction , 2013 .

[80]  S. Kuwabata,et al.  Amperometric determination of total cholesterol at gold electrodes covalently modified with cholesterol oxidase and cholesterol esterase with use of thionin as an electron mediator. , 1999, Analytical chemistry.

[81]  Jian-ping Li,et al.  A Cholesterol Biosensor Based on Entrapment of Cholesterol Oxidase in a Silicic Sol‐Gel Matrix at a Prussian Blue Modified Electrode , 2003 .

[82]  B. D. Malhotra,et al.  Mediated biosensors. , 2002, Biosensors & bioelectronics.