Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull.

INTRODUCTION The purpose of this study was to determine the accuracy and reliability of 3-dimensional craniofacial measurements obtained from cone-beam computed tomography (CBCT) scans of a dry human skull. METHODS Seventeen landmarks were identified on the skull. CBCT scans were then obtained, with 2 skull orientations during scanning. Twenty-nine interlandmark linear measurements were made directly on the skull and compared with the same measurements made on the CBCT scans. All measurements were made by 2 operators on 4 separate occasions. RESULTS The method errors were 0.19, 0.21, and 0.19 mm in the x-, y- and z-axes, respectively. Repeated measures analysis of variance (ANOVA) showed no significant intraoperator or interoperator differences. The mean measurement error was -0.01 mm (SD, 0.129 mm). Five measurement errors were found to be statistically significantly different; however, all measurement errors were below the known voxel size and clinically insignificant. No differences were found in the measurements from the 2 CBCT scan orientations of the skull. CONCLUSIONS CBCT allows for clinically accurate and reliable 3-dimensional linear measurements of the craniofacial complex. Moreover, skull orientation during CBCT scanning does not affect the accuracy or the reliability of these measurements.

[1]  C H Kau,et al.  Three-dimensional cone beam computerized tomography in orthodontics. , 2005, Journal of orthodontics.

[2]  D. Hatcher,et al.  Three-dimensional craniofacial imaging. , 2004, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[3]  K. Ueda,et al.  Using a flat-panel detector in high resolution cone beam CT for dental imaging. , 2004, Dento maxillo facial radiology.

[4]  Yoshinori Arai,et al.  A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine. , 2003, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[5]  B. Holly Broadbent,et al.  A NEW X-RAY TECHNIQUE and ITS APPLICATION TO ORTHODONTIA , 2009 .

[6]  Allan G Farman,et al.  Accuracy of linear temporomandibular joint measurements with cone beam computed tomography and digital cephalometric radiography. , 2005, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[7]  K Araki,et al.  Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRay): system configuration and physical properties. , 2004, Dento maxillo facial radiology.

[8]  Y. Hayakawa,et al.  Cone-beam CT (CB Throne) applied to dentomaxillofacial region. , 2006, The Bulletin of Tokyo Dental College.

[9]  Sheldon Baumrind,et al.  The reliability of head film measurements , 1971 .

[10]  S Baumrind,et al.  The reliability of head film measurements. 2. Conventional angular and linear measures. , 1971, American journal of orthodontics.

[11]  J Ghafari,et al.  Comparison of CT scanograms and cephalometric radiographs in craniofacial imaging. , 2002, Orthodontics & craniofacial research.

[12]  R. Verbeeck,et al.  The clinical significance of error measurement in the interpretation of treatment results. , 2001, European journal of orthodontics.

[13]  S Hassfeld,et al.  Geometric accuracy of the NewTom 9000 Cone Beam CT. , 2005, Dento maxillo facial radiology.

[14]  David C Hatcher,et al.  Comparison between traditional 2-dimensional cephalometry and a 3-dimensional approach on human dry skulls. , 2004, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[15]  M W Vannier,et al.  Three-dimensional computed tomography landmark measurement in craniofacial surgical planning: experimental validation in vitro. , 1999, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[16]  H M Pinsky,et al.  Accuracy of three-dimensional measurements using cone-beam CT. , 2006, Dento maxillo facial radiology.

[17]  P Sukovic,et al.  Cone beam computed tomography in craniofacial imaging. , 2003, Orthodontics & craniofacial research.

[18]  K W Foong,et al.  Phosphor-stimulated computed cephalometry: reliability of landmark identification. , 1997, British journal of orthodontics.

[19]  S. Brooks,et al.  Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT. , 2006, Dento maxillo facial radiology.

[20]  Haijo Jung,et al.  Quantitative evaluation of acquisition parameters in three-dimensional imaging with multidetector computed tomography using human skull phantom. , 2002, Journal of digital imaging.

[21]  Yong Kim,et al.  Quantitative Analysis of Three-dimensional Rendered Imaging of the Human Skull Acquired from Multi-Detector Row Computed Tomography , 2002, Journal of Digital Imaging.

[22]  B. S. Savara,et al.  Variability of cephalometric landmarks used for face growth studies. , 1972, American journal of orthodontics.

[23]  Y A Mostafa,et al.  Landmark identification in computerized posteroanterior cephalometrics. , 1987, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[24]  C. Lascala,et al.  Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom). , 2004, Dento maxillo facial radiology.

[25]  John B Ludlow,et al.  Accuracy of measurements of mandibular anatomy in cone beam computed tomography images. , 2007, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[26]  P W Major,et al.  Landmark identification error in posterior anterior cephalometrics. , 2009, The Angle orthodontist.

[27]  D. Hatcher,et al.  Current status and future needs in craniofacial imaging. , 2003, Orthodontics & craniofacial research.

[28]  Kaoru Kobayashi,et al.  Accuracy in measurement of distance using limited cone-beam computerized tomography. , 2004, The International journal of oral & maxillofacial implants.

[29]  Alex Jacobson,et al.  Radiographic Cephalometry: From Basics to 3-d Imaging , 2006 .

[30]  David C Hatcher,et al.  In search of anatomic truth: 3-dimensional digital modeling and the future of orthodontics. , 2002, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[31]  A. Farman,et al.  Clinical applications of cone-beam computed tomography in dental practice. , 2006, Journal.

[32]  P. Mozzo,et al.  A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results , 1998, European Radiology.

[33]  F. Linden A study of roentgenocephalometric bony landmarks. , 1971 .

[34]  David P Sarment,et al.  Accuracy of cone beam computed tomography for periodontal defect measurements. , 2006, Journal of periodontology.

[35]  Kazunori Yoshiura,et al.  The accuracy of 3-dimensional magnetic resonance 3D vibe images of the mandible: an in vitro comparison of magnetic resonance imaging and computed tomography. , 2007, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[36]  Erwin Keeve,et al.  Geometric accuracy of a newly developed cone-beam device for maxillofacial imaging. , 2007, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[37]  R. Langlais,et al.  Accuracy of Cone Beam Computed Tomography in Determining the Location of the Genial Tubercle , 2007, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[38]  M. Rosler,et al.  Error in landmark identification in lateral radiographic headplates. , 1981, European journal of orthodontics.

[39]  H. Wong,et al.  Quantitative measurement on three-dimensional computed tomography: an experimental validation using phantom objects. , 2000, Chang Gung medical journal.

[40]  M W Vannier,et al.  Validation study of skull three-dimensional computerized tomography measurements. , 1990, American journal of physical anthropology.

[41]  S Sindet-Pedersen,et al.  Comparison of the reliability of craniofacial anatomic landmarks based on cephalometric radiographs and three-dimensional CT scans. , 1997, The Cleft palate-craniofacial journal : official publication of the American Cleft Palate-Craniofacial Association.