Evaluating sample stability in the clinical laboratory with the help of linear and non-linear regression analysis

Abstract As it is common practice for laboratories to store patient samples for a predefined period, allowing clinicians to request additional tests on previously collected samples, knowledge about sample stability is indispensable for the laboratorian. A common approach to estimating the maximum storage time is to use a discrete study design, measuring the analyte of interest at various time-points and then checking for significant differences with the help of a statistical test, such as Student’s t-test, Wilcoxon’s test or an analysis of variance (ANOVA) test. Because only discrete time intervals are considered, stability data can just be approximated. Alternatively, a continuous study design, as described by the Clinical and Laboratory Standards Institute (CLSI) for performing stability experiments for in vitro diagnostic reagents, can also be adopted by the clinical laboratory to evaluate the stability of biological samples. The major advantage of this approach is that it allows laboratories to define individual stability limits for different medical situations and offers more flexibility when choosing time-points for measurements. The intent of this paper is to demonstrate the evaluation of sample stability in the clinical laboratory with a continuous study design implemented with linear or non-linear regression analysis. Appropriate statistical modeling and acceptance criteria are presented, stability functions are described briefly, and checking the overall validity of the results is discussed.

[1]  Werner Wosniok,et al.  A new concept to derive permissible limits for analytical imprecision and bias considering diagnostic requirements and technical state-of-the-art , 2011, Clinical chemistry and laboratory medicine.

[2]  Thomas Keller,et al.  Permissible measurement uncertainty in the lower part of measurement intervals , 2016 .

[3]  Werner Wosniok,et al.  Permissible limits for uncertainty of measurement in laboratory medicine , 2015, Clinical chemistry and laboratory medicine.

[4]  A. Dirican,et al.  Stability studies of common biochemical analytes in serum separator tubes with or without gel barrier subjected to various storage conditions , 2012, Biochemia medica.

[5]  A. Åsberg,et al.  Vitamin B6 in plasma – sample stability and the reference limits , 2013, Scandinavian journal of clinical and laboratory investigation.

[6]  Shine-Young Kim,et al.  Effect of Repeated Freezing and Thawing on Biomarker Stability in Plasma and Serum Samples , 2015, Osong public health and research perspectives.

[7]  Chad J Briscoe Assessing stability in bioanalysis: reflections on the last 10 years. , 2019, Bioanalysis.

[8]  A. Dirican,et al.  The effect of storage time and freeze-thaw cycles on the stability of serum samples , 2013, Biochemia medica.

[9]  Sarfaraz Niazi,et al.  Bracketing and Matrixing Designs for Stability Testing of New Drug Substances and Products , 2016, Handbook of Pharmaceutical Manufacturing Formulations, Second Edition.

[10]  Rainer Macdonald Quality assessment of quantitative analytical results in laboratory medicine by root mean square of measurement deviation / Bewertung der Qualität quantitativer analytischer Ergebnisse in der Laboratoriumsmedizin anhand des quadratischen Mittelwertes der Messabweichung , 2006 .

[11]  H. Portugal,et al.  Stability study of 81 analytes in human whole blood, in serum and in plasma. , 2012, Clinical biochemistry.

[12]  F. Nahm Nonparametric statistical tests for the continuous data: the basic concept and the practical use , 2016, Korean journal of anesthesiology.

[13]  I. El-Mahdi,et al.  The physical, chemical, and microbiological stability of chloramphenicol ophthalmic solution , 2018 .

[14]  Hans von Storch,et al.  Taking Serial Correlation into Account in Tests of the Mean. , 1995 .

[15]  B. V. Girdler-Brown,et al.  Parametric hypothesis tests for the difference between two population means , 2017 .

[16]  Karl De Vore Have more confidence in your stability data: two points to consider. , 2006 .

[17]  Farideh Alenabi,et al.  Conservation du tube primaire sur le site de dialyse en vue du dosage différé de la PTH : quels tubes ? Quelle température ? , 2009 .

[18]  Kenneth E Blick,et al.  Stability studies of twenty-four analytes in human plasma and serum. , 2002, Clinical chemistry.

[19]  Joachim Thiery,et al.  Effect of biobanking conditions on short-term stability of biomarkers in human serum and plasma , 2014, Clinical chemistry and laboratory medicine.

[20]  C. D. de Verdier,et al.  Quality specifications. , 1990, Upsala Journal of Medical Sciences.

[21]  Anders Kallner,et al.  The use of error and uncertainty methods in the medical laboratory , 2017, Clinical chemistry and laboratory medicine.

[22]  Sverre Sandberg,et al.  Defining analytical performance specifications: Consensus Statement from the 1st Strategic Conference of the European Federation of Clinical Chemistry and Laboratory Medicine , 2015, Clinical chemistry and laboratory medicine.

[23]  M. Pincus,et al.  Stability of Values for the Activities of Critical Enzymes Assayed in Serum Frozen for Prolonged Time Periods. , 2018, Annals of clinical and laboratory science.

[24]  D. Wagner,et al.  Plasma storage at -80 degrees C does not protect matrix metalloproteinase-9 from degradation. , 2005, Analytical biochemistry.

[25]  V. Álvarez,et al.  Laboratory sample stability. Is it possible to define a consensus stability function? An example of five blood magnitudes , 2018, Clinical chemistry and laboratory medicine.

[26]  B. Woodhams,et al.  Stability of coagulation proteins in frozen plasma , 2001, Blood coagulation & fibrinolysis : an international journal in haemostasis and thrombosis.

[27]  J. Budd,et al.  Multiple calibrator measurements improve accuracy and stability estimates of automated assays , 2016, Scandinavian journal of clinical and laboratory investigation.

[28]  Jean Pauwels,et al.  The study of the stability of reference materials by isochronous measurements , 1998 .

[29]  Jacob Cohen Statistical Power Analysis for the Behavioral Sciences , 1969, The SAGE Encyclopedia of Research Design.

[30]  S. Kwak,et al.  Central limit theorem: the cornerstone of modern statistics , 2017, Korean journal of anesthesiology.

[31]  J. Winter Practical Assessment, Research, and Evaluation Practical Assessment, Research, and Evaluation Using the Student's t-test with extremely small sample sizes Using the Student's t-test with extremely small sample sizes , 2022 .

[32]  W. Quapp,et al.  Test for non-linearity concerning linear calibrated chemical measurements , 2006 .

[33]  J. D. de Winter Using the Student ’ s t-test with extremely small sample sizes , 2013 .

[34]  Jean Pauwels,et al.  Planning and combining of isochronous stability studies of CRMs , 2004 .

[35]  D. Wagner,et al.  Plasma storage at −80 °C does not protect matrix metalloproteinase-9 from degradation , 2005 .