Influence of tool geometry on drilling performance of cortical and trabecular bone.

Minimally invasive surgery poses high demands on tool design. The goal was to measure the influence of drill bit geometry on maximum thrust forces required for drilling, and compare this relative to the known influence of feed rate and bone composition. Blind holes were drilled perpendicular to the iliac crest up to 10 mm depth in cadaveric pelvic bones of 20 pigs (adolescent) and 11 goats (full grown) with eight substantially different drill bits of ∅ 3-3.2 mm. Subsequently, boreholes were drilled perpendicular to the ilium with the same drill bits at three different feed rates (0.58 mm/s, 0.83 mm/s, 1.08 mm/s). The mean maximum thrust force ranges from 10 to 110 N for cortical bone, and from 3 to 65 N for trabecular bone. The results show that both drill bit geometry and feed rate have a significant influence on the maximum thrust forces, with a dominant influence of drill bit geometry in terms of shape of the flutes, sharpness of cutting edges and value of point angle. The differences in thrust forces between cortical and trabecular bone are substantial for all measured conditions. The measured values can be used for drill design.

[1]  F. Glorieux,et al.  Normative data on mineralization density distribution in iliac bone biopsies of children, adolescents and young adults. , 2009, Bone.

[2]  B. Aksakal,et al.  Influence of orthopaedic drilling parameters on temperature and histopathology of bovine tibia: an in vitro study. , 2011, Medical engineering & physics.

[3]  Randy S. Haluck,et al.  Laparoscopic Multifunctional Instruments: Design and Testing of Initial Prototypes , 2005, JSLS : Journal of the Society of Laparoendoscopic Surgeons.

[4]  Just L. Herder,et al.  A Compliant Instrument for Arthroscopic Joint Fusion , 2004 .

[5]  Just L. Herder,et al.  Steerable Mechanical Joint for High Load Transmission in Minimally Invasive Instruments , 2011 .

[6]  Albert C. Chen,et al.  Follow-Up of Osteochondral Plug Transfers in a Goat Model , 2004, The American journal of sports medicine.

[7]  Just L. Herder,et al.  Feasibility Study of a Fully Compliant Statically Balanced Laparoscopic Grasper , 2004 .

[8]  X. Guo,et al.  Assessment of trabecular and cortical architecture and mechanical competence of bone by high-resolution peripheral computed tomography: comparison with transiliac bone biopsy , 2009, Osteoporosis International.

[9]  C H Jacob,et al.  A study of the bone machining process--drilling. , 1976, Journal of biomechanics.

[10]  L. Qin,et al.  A study of trabecular bones in ovariectomized goats with micro-computed tomography and peripheral quantitative computed tomography. , 2004, Bone.

[11]  Hiroshi Iseki,et al.  Development of bending and grasping manipulator for multi degrees of freedom ultrasonically activated scalpel , 2006 .

[12]  T. Price,et al.  Recovery and safety profiles of marrow and PBSC donors: experience of the National Marrow Donor Program. , 2008, Biology of blood and marrow transplantation : journal of the American Society for Blood and Marrow Transplantation.

[13]  Benedetto Allotta,et al.  Study on a mechatronic tool for drilling in the osteosynthesis of long bones: Tool/bone interaction, modeling and experiments , 1996 .

[14]  M Hillery,et al.  Forces Generated in Guide-Wires when Drilling Human Bone , 1995, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[15]  J. Wark,et al.  The potential of sheep for the study of osteopenia: current status and comparison with other animal models. , 1995, Bone.

[16]  X. Holy,et al.  Calcium-regulating hormones, bone mineral content, breaking load and trabecular remodeling are altered in growing pigs fed calcium-deficient diets. , 1999, The Journal of nutrition.

[17]  K L Wiggins,et al.  Drilling of bone. , 1976, Journal of biomechanics.

[18]  Mamoru Mitsuishi,et al.  Development of a high dexterity, minimally-invasive surgical system with augmented force feedback capability , 2004 .

[19]  S. Warisawa,et al.  Development of High Dexterity Minimally Invasive Surgical System with Augmented Force Feedback Capability , 2004, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..

[20]  M. T. Hillerya,et al.  Temperature effects in the drilling of human and bovine bone , 1999 .

[21]  Nobuhiko Hata,et al.  Stem cell harvesting device with passive flexible drilling unit for bone marrow transplantation , 2003, IEEE Trans. Robotics Autom..

[22]  J A Albright,et al.  Surgical drilling: design and performance of an improved drill. , 1982, Journal of biomechanical engineering.

[23]  I. Denis,et al.  Effects of exogenous growth hormone on bone mineralization and remodeling and on plasma calcitriol in intact pigs. , 1994, Bone.

[24]  M. Cooper,et al.  Sciatic nerve compression following bone marrow harvest , 2000, Bone Marrow Transplantation.

[25]  K Alam,et al.  Experimental investigations of forces and torque in conventional and ultrasonically-assisted drilling of cortical bone. , 2011, Medical engineering & physics.

[26]  P. Rüegsegger,et al.  The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone. , 1999, Bone.

[27]  M. T. Hillery,et al.  Temperature effects in the drilling of human and bovine bone , 1999 .