Interlaboratory evaluations of the performance of elemental analytical methods for the forensic analysis and comparisons of electrical tapes

Abstract Adhesive tapes are an important type of evidence related to violent crimes such as the construction of improvised explosive devices and kidnappings as well as involved in other types of common evidence such as drug packaging. The methods of comparison of tape evidence consist of physical and microscopic examination followed by chemical analysis of the organic and inorganic components inherent to the tapes as part of their formulations. This work evaluates the performance of the conventional methods used in forensic analysis of adhesive tapes (physical and microscopic examination, FTIR, Py-GC-MS, and SEM-EDS) and the more recently developed elemental methods, LIBS and LA-ICP-MS, for the comparison of tape samples in different laboratories. Two interlaboratory exercises were designed to study the performance of the different analytical methods for the forensic analysis of electrical tapes. The exercises were developed with the objective to imitate forensic case scenarios where known and question tapes are compared following the laboratory’s analytical protocol. The participants were asked to compare the tape samples as in a regular forensic case. Seven (7) laboratories participated in the two interlaboratory exercises. All the laboratories performing SEM-EDS in both interlaboratory exercises (#1 and #2) were able to correctly associate the pairs of tapes originating from the same rolls, therefore the rate of false negatives was zero. Two of the laboratories performing SEM-EDS for the first interlaboratory exercise incorrectly associated two pairs of tapes belonging to different rolls, resulting in a 17% false positive rate. One of the laboratories performing SEM-EDS for interlaboratory exercise #2 incorrectly associated two pairs of tapes belonging to different rolls, resulting in a 13% false positive rate. Up to 7 and 8 elements were detected by SEM-EDS for interlaboratory exercise #1 and #2, respectively. The increased sensitivity and selectivity of LIBS and LA-ICP-MS methods allowed to distinguish all the pairs of tapes originating from different sources and for correctly associate the tapes originating from the same rolls, resulting in no false positives or false negatives. In addition, increased characterization of the samples was obtained by detecting up to 14 elements by LIBS and 27 elements by LA-ICP-MS for interlaboratory exercise #1, and 17 elements by LIBS and 32 elements by LA-ICP-MS for interlaboratory exercise #2. A match criterion of ±5 s allowed to numerically compare LIBS ratios and LA-ICP-MS signal areas for a more objective assessment of the differences between the tape samples.

[1]  J. Almirall,et al.  Signal‐to‐noise ratios in forensic glass analysis by micro X‐ray fluorescence spectrometry , 2014 .

[2]  Evan R. Williams,et al.  The Comparison of Black Polyvinylchloride (PVC) Tapes by Pyrolysis Gas Chromatography , 1988 .

[3]  Preston C. Lowe,et al.  A Validation Study for Vinyl Electrical Tape End Matches *,† , 2011, Journal of forensic sciences.

[4]  Ulrich Simmross,et al.  The Pabst's method: an effective and low-budget tool for the forensic comparison of opaque thermoplastics--part 1: Additional discrimination of black electrical tapes. , 2013, Forensic science international.

[5]  Merrill,et al.  Analysis of pressure sensitive adhesive tape: I. Evaluation of infrared ATR accessory advances , 2000, Journal of forensic sciences.

[6]  T. Schoenberger,et al.  Forensic examination of electrical tapes using high resolution magic angle spinning 1H NMR spectroscopy , 2015, Analytical and Bioanalytical Chemistry.

[7]  J. Goodpaster,et al.  Identification and Comparison of Electrical Tapes Using Instrumental and Statistical Techniques: II. Organic Composition of the Tape Backing and Adhesive * , 2009, Journal of forensic sciences.

[8]  J. Goodpaster,et al.  Identification and Comparison of Electrical Tapes Using Instrumental and Statistical Techniques: I. Microscopic Surface Texture and Elemental Composition * , 2007, Journal of forensic sciences.

[9]  J. Almirall,et al.  Elemental analysis of packaging tapes by LA-ICP-MS and LIBS , 2018 .

[10]  José R. Almirall,et al.  Characterization of toners and inkjets by laser ablation spectrochemical methods and Scanning Electron Microscopy-Energy Dispersive X-ray Spectroscopy , 2014 .

[11]  Grzegorz Zadora,et al.  Pyrolysis-gas chromatography/mass spectrometry analysis as a useful tool in forensic examination of automotive paint traces. , 2008, Journal of chromatography. A.

[12]  Maureen J. Bradley,et al.  Analysis and Discrimination of Electrical Tapes: Part II. Backings *,† , 2011, Journal of forensic sciences.

[13]  J. Almirall,et al.  Elemental analysis and characterization of electrical tape backings by LA-ICP-MS , 2017 .

[14]  Howard E. Taylor,et al.  Inductively Coupled Plasma-Mass Spectrometry: Practices and Techniques , 2000 .

[15]  Jenny C Hill,et al.  Forensic isotope ratio mass spectrometry of packaging tapes. , 2004, The Analyst.

[16]  Maureen J. Bradley,et al.  Analysis and Discrimination of Electrical Tapes: Part I. Adhesives *,† , 2011, Journal of forensic sciences.

[17]  Marianne E Dietz,et al.  Forensic utility of carbon isotope ratio variations in PVC tape backings. , 2012, Science & justice : journal of the Forensic Science Society.