Integrable electronic system for pulseoximetry/heartbeat detection

An integrated pulseoximeter/heartbeat rate detector is herewith described. The ready-to-use capability and its easy portability make the device a reliable, non-intrusive detector to be used in a large amount of applications (medical, domestic monitoring, sport scenarios). Both the blood oxygen percentage detection (i.e. pulsoximetry) and heartbeat rate monitoring are obtained thanks to a light-sensible set of diodes and receivers, by opportunely evaluating the emitted and received power light ratio through the body, using a standard technique. Test results have demonstrated that a simple 10-bit A/D converter can display both the O2 blood concentration percentage and the heartbeat rate accurately.

[1]  Y. Mendelson,et al.  Variations in optical absorption spectra of adult and fetal haemoglobins and its effect on pulse oximetry , 1989, IEEE Transactions on Biomedical Engineering.

[2]  Vincenzo Stornelli,et al.  An integrated improved CCII topology for resistive sensor application , 2006 .

[3]  P. Cochat,et al.  Et al , 2008, Archives de pediatrie : organe officiel de la Societe francaise de pediatrie.

[4]  J. L. Reuss,et al.  The pulse in reflectance pulse oximetry: Modeling and experimental studies , 2004, Journal of Clinical Monitoring and Computing.

[5]  Gang Li,et al.  Wavelength selection method based on test analysis of variance: application to oximetry , 2014 .

[6]  Preecha P. Yupapin,et al.  Noninvasive hemoglobin-measurement-based pulse oximetry , 2002, SPIE/COS Photonics Asia.

[7]  Hanli Liu,et al.  Extinction coefficients of hemoglobin for near-infrared spectroscopy of tissue , 2005, IEEE Engineering in Medicine and Biology Magazine.

[8]  M. Ishijima Monitoring of electrocardiograms in bed without utilizing body surface electrodes , 1993, IEEE Transactions on Biomedical Engineering.

[9]  G. Millikan The Oximeter, an Instrument for Measuring Continuously the Oxygen Saturation of Arterial Blood in Man , 1942 .

[10]  John W. Severinghaus,et al.  History of blood gas analysis. VII. Pulse oximetry , 1987, Journal of Clinical Monitoring.

[11]  R. King Optoelectronic Sensors in Medical Applications , 2003 .

[12]  Vincenzo Stornelli,et al.  A single current conveyor-based low voltage low power bootstrap circuit for ElectroCardioGraphy and ElectroEncephaloGraphy acquisition systems , 2014 .

[13]  S. Powers,et al.  Accuracy of pulse oximeters in estimating heart rate at rest and during exercise. , 1991, British journal of sports medicine.

[14]  N.C. Guerrini,et al.  An ultralow-power switched opamp-based 10-B integrated ADC for implantable biomedical applications , 2004, IEEE Transactions on Circuits and Systems I: Regular Papers.

[15]  Vincenzo Stornelli Low voltage Low Power Fully Differential Buffer , 2009, J. Circuits Syst. Comput..

[16]  James C. Lin,et al.  Microwave Apexcardiography , 1979 .

[17]  J. Severinghaus,et al.  History of blood gas analysis. , 1987, International anesthesiology clinics.

[18]  Zhong-Bai Zhou,et al.  Studies on the biomedical sensor techniques for real-time and dynamic monitoring of respiratory gases, CO2 and O2 , 2000 .

[19]  Lesley Gaskin,et al.  Pulse Oximetry and Exercise , 1995 .

[20]  Leonardo Pantoli,et al.  Fully differential DDA-based fifth and seventh order Bessel low pass filters and buffers for DCR radio systems , 2013 .

[21]  J.A. Adam Medical electronics , 1994, IEEE Spectrum.

[22]  Vincenzo Stornelli,et al.  A CCII-Based High Impedance Input Stage for Biomedical Applications , 2011, J. Circuits Syst. Comput..

[23]  J. Widness,et al.  Phlebotomy Overdraw in the Neonatal Intensive Care Nursery , 2000, Pediatrics.